While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

American Midwest Power 2000A 120/240V Boltswitch VLB2410 Main Fusible Switch NEMA 1 R&G

American Midwest Power INC; 2000 amp, 120/240 volt, one phase, two wire. Boltswitch VLB2410, two pole. bolted pressure contact switch, fusible main panel, single section, Nema 1 indoor. Reconditioned and guaranteed with a 1 year warranty. (M-165)
SKU: M165
Contact us for pricing:

Cutler-Hammer POW-R-LINE C 2000A 480/277V 3 Phase 4 Wire Main Fusible Switch Panel

Cutler-Hammer Pow-R-Line C; 2000 amp, Pringle fusible main, ( CBC-2033-B ), three phase, four wire, 480/277 volt. G-F-I IQ-100 power monitor bottom fed Nema-1 enclosure. Reconditioned and guaranteed with a 1 year warranty. (M-233)
SKU: M233
Contact us for pricing:

GE AV-Line 2000 Amp 480Y/277V 3Ph 4W Pringle CBC-2033-B Main Fusible Panel GFI w/ Dist R&G

General Electric AV-Line; 2000 amp, 480Y/277 volt, three phase, four wire. Pringle cat # CBC-2033-B main fusible switch with shunt trip with ground fault (GFI), Nema 1 (indoor). Reconditioned & guaranteed with a one year warranty. Contact EMSCO today to discuss this panel. The distribution can be customized to meet your needs.
SKU: M271
Contact us for pricing:

General Electric 2000A 208Y/120V 3 Ph 4W THPC3620 NEMA 3R Fusible Main Switch R&G

General Electric Spectra Series; 2000 amp, 208Y/120 volt, three phase, four wire, high pressure contact switch (HPC) cat # THPC3620, 2000 amp, 600 VAC, 3 pole, main fusible switch, Nema 3R outdoor rated. Reconditioned & guaranteed with a one year warranty. Contact EMSCO today to discuss this panel.
SKU: M250
Contact us for pricing:

General Electric AV-Line 2000 Amp 2 Pole 600V DC THPMMF76E1 Main Circuit Breaker NEMA 1 R&G

General Electric AV-Line; 2000 amp rated trip, 600 volt DC, two wire. THPMMF76E1 main circuit breaker (2500 amp frame), serial number: 249948, electrically operated (E/O), 120 volt AC, 2000 amp rating plug, 65K at 600 volt DC, single section. Reconditioned & guaranteed with a one year warranty. Contact EMSCO today to discuss this panel.
SKU: M247
Contact us for pricing:

General Electric AV-Line 2000 Amp 600 Volt 3 Phase 3 Wire THPMMF76 Main Circuit Breaker R&G

General Electric AV-Line; 2000 amp, 600 volt, three phase, three wire. THPMMF76 main circuit breaker, Nema 1, single section. Reconditioned & guaranteed with a one year warranty. Contact EMSCO today to discuss this panel.
SKU: M125
Contact us for pricing:

ITE FC-1 QA-2033 2000A 480Y/277V 3PH 4W Fusible Pringle Main Panel NEMA 1 R&G

ITE FC-1 Series 6; 2000 amp, three phase, four wire, 480Y/277 volt. Pringle #QA-2033, red back plate, fusible main switch, Nema 1 indoor. Reconditioned & guaranteed with a one year warranty. Contact EMSCO today to discuss this panel.
SKU: M269
Contact us for pricing:

ITE/Siemens 2000 Amp 480Y/277 Volt Pringle #CBC-2033-B Main Fusible Panel w/ GFI NEMA 1 R&G

ITE/Siemens FC-1 type panel; 2000 amp rated, 480Y/277 volt, three phase, four wire. Pringle #CBC-2033-B fusible main switch, bottom feed with ground fault, distribution can be added (breaker or fusible), Nema 1 indoor indoor rated. Reconditioned & guaranteed with a one year warranty. Contact EMSCO today to discuss this panel. The distribution can be customized to meet your needs.
SKU: M268
Contact us for pricing:

Siemens 2000 Amp 208Y/120V Pringle #QA2033S Main Fusible Panel NEMA 1 R&G

Siemens, 2000 amp, 208Y/120 volt, three phase, four wire. Pringle # QA2033S fusible main switch panel with circuit breaker distribution, Nema 1 indoor. Reconditioned & guaranteed with a one year warranty. Contact EMSCO today to discuss this panel. The distribution can be customized to meet your needs.
SKU: M047
Contact us for pricing:

Square D DC-Main 2000 Amp- PAF362000DC1625 500 VDC Nema 1 Free Standing R&G

Square D DC rated breaker; cat# PAF362000DC1625 2000 amp rated, 500 volt DC with 24 VDC shunt, Nema 1 indoor rated enclosure. Reconditioned & guaranteed with a one year warranty.
SKU: M235
Contact us for pricing:

General Electric AV-Line 2000 Amp 600 Volt 3 Phase 3 Wire THPMMF76 Main Circuit Breaker R&G

General Electric AV-Line; 2000 amp rated trip, 600 volt, three phase, three wire. THPMMF76 main circuit breaker, (2500A frame) with shunt trip with aux, Nema 1, single section. Reconditioned & guaranteed with a one year warranty. Contact EMSCO today to discuss this panel.
SKU: M129
Contact us for pricing:

Square D QED Power Style Switchboard 2000A Frame Main PHF2036 480Y/277V 3Ph 4W Rated at 1400A w/ Dist. LSIG R&G

Square D QED Power Style Switchboard; 2000 amp frame main cat# PHF2036 with rating plug cat #ARP100, 480Y/277 volt, three phase, four wire, rated at 1400 amp, distribution section, LSIG functions. Reconditioned & guaranteed with a one year warranty.
SKU: M346
Contact us for pricing:

Westinghouse Switchboard MLO 2000 Amp 480Y/277 Volt W/ Fusible Dist & FDP Nema 1 R&G

Westinghouse Switchboard; 2000 amp, main lug only, 480Y/277 volt with fusible distribution & FDP, with ground fault, Nema 1 indoor. Reconditioned & guaranteed with a one year warranty.
SKU: M356
Contact us for pricing:

GE THPC3620G3T Switchboard 2000 Amp Main Breaker 480Y/277 VAC W/ Fusible Spectra Dist. Nema 3R R&G

General Electric THPC3620G3T Switchboard; 2000 amp main breaker, 480Y/277 volt AC with ground fault, fusible spectra distribution, Nema 3R outdoor. Reconditioned & guaranteed with a one year warranty.
SKU: M357
Contact us for pricing:

Square D Power Style Switchboard 2000 Amp Fusible Main 480Y/277 Volt w/ GF NEMA 1 R&G

Square D Power Style Switchboard; 2000 amp fusible main with ground fault, 480Y/277 volt, 3 phase, 4 wire, NEMA 1 indoor rated. Reconditioned & guaranteed with a one year warranty.
SKU: M385
Contact us for pricing:

AMP F-BPS/FDP Switchboard Fusible Main VLB3410-ST Boltswitch 2000 Amp 480Y/277 Volt NEMA 1 R&G

American Midwest Power F-BPS/FDP Switchboard fusible main VLB3410-ST boltswitch; 2000 amp, 480Y/277 volt, ground fault relay, Nema 1 indoor. Reconditioned & guaranteed with a one year warranty.
SKU: M429
Contact us for pricing:

GE Spectra Series Switchboard 2000 Amp 480Y/277 Volt Fusible Main W/ GF & Spectra Breaker Dist. Nema 3R R&G

General Electric THPC23620B Spectra Series Switchboard; 2000 amp high pressure contact switch fusible main with ground fault & spectra breaker distribution, 480Y/277 volt AC, three pole, four-wire, NEMA 3R outdoor. Reconditioned & guaranteed with a one year warranty.
SKU: M455
Contact us for pricing:

Peterson Electric 2000 amp 480Y/277 volt VLB3410-06 Fusible Main W/ GF NEMA 1 R&G

Peterson Electric boltswitch bolted pressure contact switch: 2000 amp, cat# VLB3410-06 fusible main with GFI, 480Y/277 volt AC, 3 pole, 4 wire, ground fault relay cat# GFR-1, NEMA 1 indoor. With (2) L367-X3 boltswitch bolted pressure contact switch- 800 amp, 600 volt, 3 pole, 3 wire. With (1) V7H3606 vacu- break switch: 600 amp, 600 volts max, 3 pole, 3 phase. With (1) V7H3605 vacu-break switch: 400 amp, 600 volts max, 3 poles, 3 phase, series A. Reconditioned & guaranteed with a one year warranty.
SKU: M456
Contact us for pricing:

SQ D Power Style Switchboard BP03620I Fusible 2000 Amp 480 Volt AC NEMA 3R R&G

Square D Power Style Switchboard BP03620I fusible; 2000 amp fusible main, 480 volt AC, three pole, NEMA 3R outdoor. Reconditioned & guaranteed with a one year warranty.
SKU: M472
Contact us for pricing:

States Electric Co. SE-13473 Dead Front Switchboard 2000A 3PH 4W 480Y/277V NEMA 1 R&G

States Electric Company Dead Front Switchboard; 2000 amp, three phase, four wire, 480Y/277 volt, Nema 1 indoor. Reconditioned & guaranteed with a one year warranty.
SKU: M500
Contact us for pricing:

Upgrade Low Voltage Switchgear: New, Refurbished, Obsolete

We don’t just sell Low Voltage Switchgear. We provide tailored solutions by understanding your situation as a trusted partner in identifying what you need. Asking questions like:

What are the Voltage Rating Requirements?

Let’s make sure the switchgear's voltage rating matches the requirements of the electrical system it will be installed in. Low voltage switchgear typically operates at voltages up to 1000V AC or 1500V DC. Beyond this, consider Medium Voltage switchgear.

What is the Maximum Current Rating?

It’s important to know the maximum current that the switchgear can handle safely. This should align with the expected load and short-circuit currents in the system.

Where is the Operating Environment?

Evaluate the environmental conditions where the switchgear will be installed, including temperature, humidity, dust, and corrosive elements. Choose switchgear with appropriate ingress protection (IP) ratings and environmental certifications.

What Type of Protection is Needed?

By knowing this, we can decide whether the application requires protection against overload, short circuit, or both. Select switchgear with built-in protection features such as circuit breakers, fuses, or protective relays as needed.

How Much Space Do You Have:

Consider the physical dimensions and layout of the installation site to ensure the switchgear fits properly and allows for future expansion if necessary.

Which Safety Standards Need to Be Met?

Verifying the switchgear complies with relevant safety standards and certifications such as IEC, ANSI, UL, or other local regulations. This way the equipment meets minimum safety requirements and performance standards.

What About Reliability and Durability?

Look for switchgear from reputable manufacturers known for producing reliable and durable equipment. Consider factors such as component quality, design robustness, and maintenance requirements.

Is Remote Monitoring and Control Needed?

If remote monitoring and control are desired, choose switchgear with compatible communication interfaces (such as Modbus, Profibus, or Ethernet) and software capabilities for seamless integration into the overall control system.

Have You Considered Arc Flash Mitigation?

Evaluate the switchgear's ability to minimize the risk and severity of arc flash incidents through design features such as arc-resistant construction, fast fault-clearing times, and proper equipment labeling.

What About Cost and Total Ownership?

Assess the initial purchase cost along with long-term maintenance, operating costs, and potential energy savings. Consider the total cost of ownership over the switchgear's lifecycle to make an informed investment decision.

 

How Can We Help?

Let us help you choose the right Low Voltage Switchgear Solution with confidence. You have customized low voltage switchgear needs? We'll match voltage levels, load capacity, and fault current ratings, to name a few considerations. Your switchgear has special demands, so our solutions balance upfront costs with long-term value, with each unit undergoing testing to lower your total cost over its lifespan.