Low Voltage Switchgear

While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

Eaton Pow-R-Line Switchboard 1600 Amp 480Y/277 Volt 3Ph 4W NEMA 1 R&G

Eaton Pow-R-Line Switchboard; 1600 amp main breaker, 480Y/277 volt AC, 3 phase, 4 wire, ground fault indicator, arc flash reduction, surge protective device, NEMA 1 indoor rated. Reconditioned & guaranteed with a one year warranty.
SKU: M605
Contact us for pricing:

Square D QED Power Style Switchboard 2000 Amp PXF362000G 480Y/277 Volt NEMA 1 R&G

Square D QED Power Style Switchboard; 2000 amp main breaker, cat# PXF362000G, 480Y/277 volt NEMA 1 indoor rated. With I-line distribution. Reconditioned & guaranteed with a one-year warranty.
SKU: M606
Contact us for pricing:

Square D QED Power Style Switchboard 1600 Amp 480Y/277 Volt 3PH 4W NEMA 1 R&G

Square D QED Power Style Switchboard; 1600 amp main breaker, 480 volt, three phase, four-wire, NEMA 1 indoor rated. Reconditioned & guaranteed with a one year warranty.
SKU: M608
Contact us for pricing:

Siemens SB3 Switchboard 2500 Amp 480Y/277 Volt 3 Ph 4W NEMA 1 R&G

Siemens SB3 Switchboard; 2500 amp, cat# SBS4025, 480Y/277 volt, 3 phase, 4 wire, LSIG functions, ground fault, NEMA 1 indoor rated. Reconditioned & guaranteed with a one-year warranty.
SKU: M609
Contact us for pricing:

Square D QED Power Style Switchboard 4000 Amp MLO 480Y/277 Volt 3 Ph 4W NEMA 1 R&G

Square D QED Power Style Switchboard; 4000 amp, main lug only, 480Y/277 volt, 3 phase, 4 wire, NEMA 1 indoor rated, LSIG functions, ground fault, distribution breakers. Reconditioned & guaranteed with a one-year warranty.
SKU: M607
Contact us for pricing:

Cutler-Hammer Magnum DS Switchboard 4000 Amp 480Y/277 Volt AC 3 PH 4W NEMA 1 R&G

Cutler-Hammer Magnum DS Switchboard; 4000 amp,480Y/277 volt AC, 3 phase, 4 wire, NEMA 1 indoor, LSIG functions, ground fault, with Magnum DS breaker distribution. Reconditioned & guaranteed with a one-year warranty.
SKU: M610
Contact us for pricing:

Square D QED Power Style Switchboard 3000 Amp Fusible Main 480Y/277 Volt w/ GFI 3 PH 4 W NEMA 1 R&G

Square D QED Power Style Switchboard; 3000 amp fusible main with ground fault, 480Y/277 volt, 3 phase, 4 wire, NEMA 1 indoor rated. With I-line breaker distribution section. Reconditioned & guaranteed with a one year warranty.
SKU: M611
Contact us for pricing:

Square D QED Power Style Switchboard 2000 Amp Fusible Main 480Y/277 Volt w/ GFI 3 PH 4 W NEMA 1 R&G

Square D QED Power Style Switchboard; 2000 amp fusible main with ground fault, 480Y/277 volt, 3 phase, 4 wire, NEMA 1 indoor rated. With I-line breaker distribution section. Reconditioned & guaranteed with a one year warranty.
SKU: M612
Contact us for pricing:

Square D QED Power Style Switchboard 1600 Amp480Y/277 Volt 3 Ph 4 W NEMA 1 R&G

Square D QED Power Style Switchboard; 1600 amp main breaker, 480Y/277 volt, 3 phase, 4 wire, NEMA 1 indoor. Reconditioned &guaranteed with a one-year warranty.
SKU: M578
Contact us for pricing:

GE/ ABB Reliagear Switchboard 2000 Amp Main Breaker 480Y/277 Volt 3 Ph 4 W GFI R&G

General Electric/ ABB Reliagear Switchboard; 2000 amp main breaker cat# SSF20G220, 480Y/ 277 volt, 3 phase, 4 wire, ground fault, arc flash reduction. With ABB TMAX breaker distribution. Reconditioned and guaranteed with a one-year warranty.
SKU: M613
Contact us for pricing:

Square D QED Power Style Switchboard 2500 Amp Fusible Main 208Y/120 Volt 3 Ph 4 W NEMA 1 R&G

Square D QED Power Style Switchboard; 2500 amp fusible main, 208Y/120 volt, 3 phase, 4 wire, NEMA 1 indoor rated. With 2 sections of fusible QMBW fusible distribution. Reconditioned & guaranteed with a one year warranty.
SKU: M614
Contact us for pricing:

Square D QED Power Style Switchboard 800 Amp 480Y/277 Volt 3Ph 4 W NEMA 1 R&G

Square D QED Power Style Switchboard; 800 amp main breaker, 480Y/277 volt, 3 phase, 4 wire, NEMA 1 indoor rated. With I-line breaker distribution. Reconditioned & guaranteed with a one-year warranty.
SKU: M617
Contact us for pricing:

Square D QED Power Style Switchboard 800 Amp 480Y/277 Volt 3Ph 4 W NEMA 1 R&G

Square D QED Power Style Switchboard; 800 amp main breaker, 480Y/277 volt, 3 phase, 4 wire, NEMA 1 indoor rated. With I-line breaker distribution. Reconditioned & guaranteed with a one-year warranty.
SKU: M618
Contact us for pricing:

Upgrade Low Voltage Switchgear: New, Refurbished, Obsolete

We don’t just sell Low Voltage Switchgear. We provide tailored solutions by understanding your situation as a trusted partner in identifying what you need. Asking questions like:

What are the Voltage Rating Requirements?

Let’s make sure the switchgear's voltage rating matches the requirements of the electrical system it will be installed in. Low voltage switchgear typically operates at voltages up to 1000V AC or 1500V DC. Beyond this, consider Medium Voltage switchgear.

What is the Maximum Current Rating?

It’s important to know the maximum current that the switchgear can handle safely. This should align with the expected load and short-circuit currents in the system.

Where is the Operating Environment?

Evaluate the environmental conditions where the switchgear will be installed, including temperature, humidity, dust, and corrosive elements. Choose switchgear with appropriate ingress protection (IP) ratings and environmental certifications.

What Type of Protection is Needed?

By knowing this, we can decide whether the application requires protection against overload, short circuit, or both. Select switchgear with built-in protection features such as circuit breakers, fuses, or protective relays as needed.

How Much Space Do You Have:

Consider the physical dimensions and layout of the installation site to ensure the switchgear fits properly and allows for future expansion if necessary.

Which Safety Standards Need to Be Met?

Verifying the switchgear complies with relevant safety standards and certifications such as IEC, ANSI, UL, or other local regulations. This way the equipment meets minimum safety requirements and performance standards.

What About Reliability and Durability?

Look for switchgear from reputable manufacturers known for producing reliable and durable equipment. Consider factors such as component quality, design robustness, and maintenance requirements.

Is Remote Monitoring and Control Needed?

If remote monitoring and control are desired, choose switchgear with compatible communication interfaces (such as Modbus, Profibus, or Ethernet) and software capabilities for seamless integration into the overall control system.

Have You Considered Arc Flash Mitigation?

Evaluate the switchgear's ability to minimize the risk and severity of arc flash incidents through design features such as arc-resistant construction, fast fault-clearing times, and proper equipment labeling.

What About Cost and Total Ownership?

Assess the initial purchase cost along with long-term maintenance, operating costs, and potential energy savings. Consider the total cost of ownership over the switchgear's lifecycle to make an informed investment decision.

 

How Can We Help?

Let us help you choose the right Low Voltage Switchgear Solution with confidence. You have customized low voltage switchgear needs? We'll match voltage levels, load capacity, and fault current ratings, to name a few considerations. Your switchgear has special demands, so our solutions balance upfront costs with long-term value, with each unit undergoing testing to lower your total cost over its lifespan.