Low Voltage Switchgear

Please note that our available online inventory is only a sampling of our available in-stock inventory. If you cannot locate the product you need, please call us at 1-800-328-1842. Our sales team will be happy to find it for you.

American Midwest Power 600 Amp 208Y120V 3PH 4W J366WOL NEMA 3R Fusible Main Switch (M-254)

American Midwest Power: 600 amp, 208/120 volt, three phase, four-wire. J366WOL main fusible switch with Square D Power Logic PM800, NEMA 3R.
SKU: M-254
Contact us for pricing:

AMP 2000A 120/240V 1PH 3W Boltswitch VLB2410 Main Fusible Switch NEMA 1 (M-165)

American Midwest Power INC; 2000 amp, 120/240 volt, 1 phase, 3 wire. Boltswitch VLB2410, 2 pole. bolted pressure contact switch, fusible main panel single section, Nema 1. Contact EMSCO today to discuss this panel.
SKU: M-165
Contact us for pricing:

AMP Series 1200 Amp 3 Phase 4 Wire VLB348-ST Main Fusible panel w/ GFI (M-131)

American Midwest Power; 1200 amp, 3 phase, four-wire, VLB348-ST w/ GFI panel. Contact EMSCO today to discuss this panel.
SKU: M-131
Contact us for pricing:

C-H POW-R-LINE C 2000A 3 Phase 4 Wire Main Fusible Switch Panel (M-233)

C-H Pow-R-Line C; 2000 amp, Pringle fusible main, ( CBC-2033-B ) three phase, four wire, 480/277 volt. G-F-I IQ-100 power monitor bottom fed Nema-1 enclosure.
SKU: M-233
Contact us for pricing:

Challenger FA-1 Switchboard 1200A 208Y/120 Volt 3Ph 4W FDPS368B Fusible Main Panel (M-264)

Challenger FA-1 Switchboard; 1200 amp, 208Y/120 volt, 3 phase, 4 wire. FDPS368B fused main switch, FDP type distribution, Nema-1, 2 sections. Contact EMSCO today to discuss this panel. The distribution can be customized to meet your needs (Loc: Pillar 145)
SKU: M-264
Contact us for pricing:

Challenger type FDP FA1W 2500 Amp 3 Phase 4 Wire 480Y/277 Volt VL3611-GC Fusible Main panel (M-110)

Challenger Model FA1W type FDP; 2500 amp, 3 phase, 4 wire. VL3611-GC fusible main w/ ground fault panel. Contact EMSCO today to discuss this panel. The distribution can be customized to meet your needs.
SKU: M-110
Contact us for pricing:

Challenger/FPE FA-1 Switchboard 1600 Amp 480Y/277 Volt 3 Phase 4 Wire w/ GFI VL369-ST Fusible Main Panel (M-071)

Challenger/Federal Pacific FA-1 switchboard; 1600 amp, 480Y/277 volt, 3 phase, 4 wire. VL-369-ST main with ground fault, Nema-1. Contact EMSCO today to discuss this panel. The distribution can be customized to meet your needs.
SKU: M-071
Contact us for pricing:

Cutler Hammer Power Line C 4000 Amp 480/277 Volt 3 Phase 4 Wire Main Fused Switch With PRL Breaker Distribution

Cutler-Hammer 2 - section line-up power line C (PRL) Pringle; 4000 amp, main switch - QA-4033-CBC with ground fault, 480/277 volt, three phase, four wire. With CT compartment above main with one section of circuit breaker distribution, cutler hammer C-Series, Nema 1 rated. Contact EMSCO today to discuss this panel. The distribution can be customized to meet your needs.
SKU: M-191
Contact us for pricing:

Cutler Hammer Westinghouse Pow-R-Line C Switchboard 1200 Amp 3 Phase 480/277 Volt CBC-1233-B Fusible Main Panel NEMA 1 w/ GF R&G

Cutler-Hammer / Westinghouse Pow-R-Line C 1200 amp, three phase, four wire, NEMA 1. Pringle fusible main: CBC-1233-B with ground fault. Circuit breaker type distribution panel R&G. Used electrically OK.
SKU: M-246
Contact us for pricing:

Cutler-Hammer 3000 Amp 480/277 Volt 3 Phase 4 Wire QA3033CBC Main Fusible Panel w/ GFI NEMA 1 (M-147)

Cutler-Hammer; 3000 amp, 480/277 volt, three phase, four wire. QA3033CBC main fusible switch Pow-R-Line. C 2 - sections with ground fault, with fusible distribution (FDPW), Nema 1, indoor, M-147. Contact EMSCO today to discuss this panel. The distribution can be customized to meet your needs.
SKU: M-147
Contact us for pricing:

Cutler-Hammer Magnum DS Metal Enclosed LV Switchgear 3200A Main-Tie-Main 4W w/GF

Cutler-Hammer Magnum DS metal-enclosed LV switchgear; 3200 amp, main-tie-main, 480/277 VAC, 3 phase, 4 wire with ground fault. Six (6) sections of structure. Cutler-Hammer magnum DS breakers, Three (3) MDS632 - 3200 amp frame, with 3200 amp trip, with LSIG (2 Mains and 1 Tie). Seven (7) MDS620 - 2000 amp frame, with 1200 amp trip, with LSIG (Feeders). All breakers are manually operated.
SKU: SWGR-004

Cutler-Hammer MP-Style 1200 Amp 3 Phase 4 Wire VLB348-ST Main Fusible panel (M-039)

Cutler-Hammer MP-Style; 1200 amp, 480/277 volt, three phase, four wire. VLB348-ST main fusible panel with M50 fusible distribution (IE: Westinghouse/FDP-Style switches). Contact EMSCO today to discuss this panel. The distribution can be customized to meet your needs.
SKU: M-039
Contact us for pricing:

Cutler-Hammer Power Line C 1600 Amp 480/277 Volt 3 Phase 4 Wire Panel

Cutler-Hammer Pow-R-Line C; 1600 amp, 480/277 volt, 3 phase, 4 wire, main-tie-main style panel. Three (3) RDC316T33W (100k) breakers: One (1) with 1600 amp rating plug, One (1) with 800 amp rating plug, One (1) with 800 amp rating plug; Nema-1 enclosure.
SKU: M-219
Contact us for pricing:

Cutler-Hammer Pow-R-Line C Section 2000 Amp 3 Phase 3 Wire 480 Volt RD320T32W Main Circuit Breaker

Cutler-Hammer Pow-R-Line C; 2000 amp, 3 phase, 3 wire, 480 volts RD320T32W circuit breaker main with digi-trip 310 with short time, single section, Nema 1. Contact EMSCO today to discuss this panel. The distribution can be customized to meet your needs.
SKU: M-121
Contact us for pricing:

Cutler-Hammer/Westinghouse Pow-R-Line C Switchboard 3000A 3Ph 4W CBC-3033-B Fusible Main Panel

Cutler-Hammer/Westinghouse Pow-R-Line C; 3000 amp, three phase, four wire. Fusible main: CBC-3033-B with ground fault, RDC frame, 2000 amp digi-trip. RMS 310 cat# RES2000LS, 2000 amp rating plug cat# 20RES20T. Contact EMSCO today to discuss this panel. The distribution can be customized to meet your needs.
SKU: M-278
Contact us for pricing:

Eaton/Cutler-Hammer Pow-R-Line C Switchboard 1600A 3ph 4w CRD316T106W Main-Tie-Main Breaker Panel

Eaton/Cutler-Hammer Pow-R-Line C; 1600 amp, 3 phase, 4 wire, 3200 amp. Neutral ground fault section 1: main breaker - CRD316T106W, digi-trip, OPTIM 1050 programmable trip unit, (Cat# P106LSIG) with LSIG functions. 1600 amp rating plug (0RPR16A150), clipper power system, 400KA surge protection device, section 2: C series breaker distribution section, 6- CHKD3400T106W (4- 225 amp rated 2- 200 amp rated), 1- CHKD3250T106W (225 amp rated), 1- CHKD3125T106W (100 amp rated), 1- HFDE3080 with ground fault, 80 amp section, 3: tie breaker (CRD316T106W), digi-trip, OPTIM 1050 programmable trip unit (Cat# P106LSIG) with LSIG functions, 1600 amp rating plug (0RPR16A150). Breaker interface module II, section 4: C series breaker distribution, section 2- CHKD3400T106W (1- 400 amp rated 1- 225 amp rated), 4- CHKD3250T106W (4- 125 amp rated), 1- HFDE3070 with ground fault, 70 amp, section 5: C series breaker distribution section. Sold 2- CHKD3400T106W (2- 225 amp rated), 2- CHKD3250T106W (125 amp rated), 1- CHKD3125T106W (4- 100 amp rated), section : main breaker - CRD316T106W Sold digi-trip, OPTIM 1050 programmable trip unit, (Cat# P106LSIG) with LSIG functions. 1600 amp rating plug (0RPR16A150), clipper power system, 400KA surge protection device panel. Contact EMSCO today to discuss this panel. The distribution can be customized to meet your needs.
SKU: M-159
Contact us for pricing:

EMI 3000A 3Ph 4W Boltswitch VLB3412 Fusible Main (M-252)

Electro-Mechanical Industries; 3000 amp, 480/277 volt, three phase, four wire. Boltswitch cat # VLB3412 bolted pressure contact switch single section. Used electrically OK.
SKU: M-252
Contact us for pricing:

Erickson Electric Panel 4000 Amp Main Switch SL-3616-G6 w/ Ground Fault Nema 1

Erickson Electric Panel; boltswitch fusible main, cat# SL-3613-G6, 4000 amp, three phase, four wire, 480/277 volt with ground fault with SPB breaker distribution. (8) SPB-100 breakers manually operated with 400-800 amp rated trip units, Nema 1 rated. Loc: P-134
SKU: M-227
Contact us for pricing:

FPE 2000 Amp 480/277 Volt 3 Phase 4 Wire VL3610-ST Main Fusible Panel w/ GFI NEMA 1 (M-132)

Federal Pacific Electronic FA1 Switchboard; 2000 amp, 480/277 volt, three phase, four wire. Boltswitch bolted pressure contact switch cat # VL3610-ST, fusible main switch. Panel with ground fault with type GLR-T ground relay, Nema 1 indoor. Contact EMSCO today to discuss this panel. The distribution can be customized to meet your needs.
SKU: M-132
Contact us for pricing:

GE AV Line 1600 Amp 3 Phase 4 Wire 480Y/277V TP1616SS Main Breaker w/ Ground Fault Panel

General Electric AV Line; 1600 amp, 480/277 volt, 3 phase, 4 wire. TP1616SS power break main with MicroVersaTrip plus trip unit (C216LSIGR) with ground fault (LSIG Functions) panel with breaker distribution. Contact EMSCO today to discuss this panel. The distribtution can be customized to meet your needs.
SKU: M-104
Contact us for pricing:

EMSCO has been specializing in used and refurbished low voltage switchgear options for over 72 years. Need help identifying the low voltage switchgear you need to replace, use our website to find it.