Air Circuit Breakers

While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

5HK BBC Air Circuit Breaker 1200A 4.76KV EO/DO

BBC 5HK Power Circuit Breaker; 1200 amp, 4.76 KV. Electric operated, draw-out, closing volts: 125-VDC. Used sold electrically OK.
SKU: 5HK-EO-DO-#22771

K-1600S BBC Air Breaker 1600A 600V MO/DO LIG

BBC K-1600S Power Circuit Breaker; 1600 amps, 600 volts. Manually operated, draw-out, red insulators, solid state trip, type SS with LIG functions. Used electrically OK.
SKU: K-1600S-MO-DO-LIG-#22782

K-1600S BBC Air Breaker 1600A 600V MO/DO LIG

BBC K-1600S Power Circuit Breaker; 1600 amps, 600 volts. Manually operated, draw-out, black Insulators, solid state trip, type SS with LIG functions. Used electrically OK.
SKU: K-1600S-MO-DO-LIG-#22783

K-1600S BBC Air Breaker 600V 1600A EO/DO LSI RED

BBC K-1600S Power Circuit Breaker; 1600 amps, 600 volts, red back plate. Electrically operated, draw-out, solid state trip, type SS with LSI functions. Used electrically OK.
SKU: K-1600S-EO-DO-#23086

K-DON1600S ITE/BBC 1600A EO/DO Air Breaker LSI

ITE/BBC K-Don 1600S Air Circuit Breaker; 1600 amp, 600 volt, red insulators, type-SS trip with L-S-I functions. Electrically operated, draw-out, 120 volt. Used electrically OK.
SKU: K-DON1600S EMSCO#20291

K-DON1600S ITE/BBC 1600A 600V EO/DO Air Breaker LSI

ITE/BBC K-Don 1600S Air Circuit Breaker; 1600 amp, 600 volt, red insulators, OD-3 trip with L-S-I functions. Electrically operated, draw-out, 120 volt. Used electrically OK.
SKU: K-DON1600S EMSCO#20292

K-DON 1600S ITE/BBC 1600A 600V EO/ST Air Breaker LSI

ITE/BBC K-Don 1600S Fused Power Circuit Breaker; 1600 amp, 600 volt. Electrically-operated, draw-out, trip: Digitrip 510 with L-S-I functions. Used Electrically OK.
SKU: K-DON1600S EMSCO#20949

LK16 ITE/BBC 1600A 600V 120VAC EO/DO Power Circuit Breaker LSI

ITE/BBC LK16 Brown Boveri A.C. Low Voltage Power Circuit Breaker; 1600 amp frame, 1600 amp sensors, 600 volt AC. Electrically operated, draw-out, charge: 120 VAC, close: 120 VAC, trip: 120 VAC, Micro-power Shield Type MPS-5 with LSI functions. Used electrically OK.
SKU: LK-16 # 20637

LK16 ITE/BBC 1600A 600V MO/DO LSG Air Circuit Breaker

ITE/BBC LK16 Brown Boveri A.C. Low Voltage Power Circuit Breaker; 1600 amp frame, 1600 amp sensors, 600 volt AC. Manually operated, draw-out, Micro-power Shield Type MPS-4G with LSG functions. Used electrically OK.
SKU: LK-16 # 20900

LK20 ITE/BBC 2000A 600V EO/DO Air Breaker LS

ITE/BBC LK20 Low Voltage Power Circuit Breaker; 2000 amp rated, 2000 amp CT, 600 volt. Electrically operated, draw-out, 125 volt DC, control trip: MPS-4 with LS functions. Used Electrically OK.
SKU: LK20 #21397

LK20 ITE/BBC 2000A MO/DO Air Breaker LS

ITE/BBC LK20 low voltage power circuit breaker; 2000 amp frame, 2000 amp C.T. Manually operated, draw-out, 125 VDC trip, Micro-power shield type MPS 4 "LS" functions. Used electrically OK.
SKU: LK20 EMSCO #20888

LK20 ITE/BBC 2000A MO/DO Air Breaker LS

ITE/BBC LK20 Low Voltage Power Circuit Breaker; 2000 amp rated, 2000 amp CT, 600 volt. Manually operated, draw-out, trip: MPS-4 with LS functions. Used Electrically OK.
SKU: LK20 #21398

LK20 BBC 2000A 600V MO/DO Air Breaker

BBC LK20 Low Voltage Circuit Breaker; 2000 amp rated, no CT, 600 volt. Manually operated, draw-out, no trip unit. Used Electrically OK.
SKU: LK20 #21403

LK25 ITE/BBC 2500A 600V MO/DO Power Circuit Breaker LSG

ITE/BBC LK25 Brown Boveri A.C. low voltage power circuit breaker; 2500 amp frame, 2500 amp sensors, 600 volt AC. Manually operated, draw-out, solid state trip device #LSS4 with LSG functions. Sold used as is.
SKU: LK25 EMSCO #21393

LK25 ITE/BBC 2500A 600V MO/DO Power Circuit Breaker LSIG

ITE/BBC LK25 Brown Boveri A.C. low voltage power circuit breaker; 2500 amp frame, 2500 amp sensors, 600 volt AC. Manually operated, draw-out, solid state trip device #LSS4 with LSIG functions. Sold used as is.
SKU: LK25 EMSCO #20862

LK25 ITE/BBC 2500A 600V MO/DO Air Breaker LSG

ITE/BBC LK25 Low Voltage Power Circuit Breaker; 2500 amp, 600 volt. Manually operated, draw-out, trip: LSS4 with L-S-G. Used Electrically OK.
SKU: LK25 #20898

LK25 ITE/BBC 2500A 600V MO/DO Air Breaker LSG

ITE/BBC LK25 Low Voltage Power Circuit Breaker; 2500 amp, 600 volt. Manually operated, draw-out, trip: LSS4 with L-S-G. Used Electrically OK.
SKU: LK25 #20899

LK-25 BBC/ITE 2500A 600V AC Low Voltage Air Circuit Breaker MO/DO LSG

BBC/ITE LK-25 Brown Boveri AC Low Voltage Power Circuit Breaker; 2500 amp frame, 2500 amp sensors, 600 volt AC. Manually operated, draw-out, Solid State Trip Device Type LSS 4 with LSG functions. Sold Used As Is.
SKU: LK25 EMSCO #20674

LK42 ABB/BBC 4200A 600V EO/DO Air Circuit Breaker LSG

ABB/BBC LK42 Brown Boveri A.C. Low Voltage Power Circuit Breaker; 4200 amp frame, 4200 amp sensors, 600 volt AC. Electrically operated, draw-out, charge: 240 VAC, close: 240 VAC, trip: 240 VDC, Micro-power Shield Type MPS-4G with LSG functions. Used electrically OK.
SKU: LK-42 # 21379

LK42 ITE/BBC 4200A 600V MO/DO Air Circuit Breaker LS

ITE/BBC LK42 Brown Boveri A.C. Low Voltage Power Circuit Breaker; 4200 amp frame, 4200 amp sensors, 600 volt AC. Manual operated, draw-out, Trip Unit Type LSS-4 with LS functions. Used Electrically OK.
SKU: LK-42 # 21392

Used and Refurbished Air Circuit Breakers

Air Circuit Breakers (ACB’s) use air to extinguish electrical sparks. When a fault occurs, these circuit breakers disrupt the circuit by releasing a burst of compressed air, extinguishing the arc. This isolates the defective section of the system, preventing damage. High-pressure air cools the electrical arc.

Inventory Selection of Air Circuit Breakers to Match and Replace Yours

Our inventory features a wide range of air circuit breaker types to match and replace your existing electrical equipment seamlessly, ensuring compatibility and optimal performance for different applications. Whether you need a specific voltage rating, current capacity, or unique design, we have options that suit your needs.

New and Refurbished Air Circuit Breakers -- It's Your Choice

We offer customers the flexibility to choose between new and refurbished ACB’s. New circuit breakers ensure the latest technology and warranties, while refurbished breakers provide cost-effective solutions without compromising quality, backed by thorough inspections and testing.

Electrical testing equipment Certifies Quality and Performance

Our products undergo rigorous electrical testing using the newest test equipment to guarantee quality, safety, and optimal performance. Each air circuit breaker is thoroughly inspected, ensuring it meets industry standards and specifications.

Specifications Based on Your Power Requirements

To specify the right air circuit breaker, consider power requirements such as voltage, current rating, breaking capacity, and the type of application. In most cases, air circuit breakers are used where there’s high risk of fire or explosion. Air Breakers are typically used for low voltages up to 15KV.

Our expert team can guide you through selecting the most suitable breaker for your specific power needs.

What Type of Air Circuit Breaker Do You Need?

Air Breaker Type

How the Breaker Type Works

Applications

Plain Break Air Breaker

Utilizes a pair of contacts within a chamber filled with air to interrupt the electrical circuit. When the contacts separate, an arc forms and is extinguished by the surrounding air.

Commonly used in low-voltage applications like residential and commercial settings, protecting against overcurrents and short circuits.

Magnetic Blowout Air Breaker

Uses a magnetic field to drive the arc away from the contacts, ensuring quick interruption and extinguishing of the arc. The magnetic force redirects the arc into a chute, effectively extinguishing it.

Often found in industrial and heavy-duty settings due to their capability to handle high fault currents, making them ideal for heavy machinery and large-scale equipment protection.

Air Chute Breaker

Uses a series of parallel plates to create a chute for the arc. When the contacts open, the arc is diverted into the chute, where it is elongated, cooled, and extinguished before being directed toward the exhaust vent.

Commonly applied in medium-voltage power distribution systems, particularly in substations, to protect transformers and other critical power equipment from faults and overloads.

Air Blast Breaker

Relies on a high-pressure air blast to extinguish the arc. The compressed air directed towards the arc causes rapid cooling and interruption, ensuring efficient breaking of the circuit.

Primarily utilized in high-voltage applications like power stations and critical infrastructure such as data centers and hospitals, offering reliable protection against high fault currents and maintaining system integrity.