While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

ITE FCI Series 6 Switchboard | 1600 Amp Main Lug Only | 480Y/277V 3-Phase 4-Wire | NEMA 1 R&G

ITE FCI Series 6 Switchboard; 1600 amp, main lug only, 480Y/277 volt, 3 phase, 4 wire, NEMA 1 indoor rated. With (2) V7 distribution switch panels. Reconditioned & guaranteed with a one-year warranty.
SKU: M647
Contact us for pricing:

Siemen FC I Series 6 Switchboard | 2000 Amp Main Lug Only | 480Y/277V 3-Phase 4-Wire | NEMA 1 R&G

Siemens FC I Series 6 Switchboard; 2000 amp main lug only, 480Y/277 volt, 3 phase, 4 wire, NEMA 1 indoor. With (3) fusible distribution panels. Reconditioned & guaranteed with a one-year warranty.
SKU: M602
Contact us for pricing:

Siemens FC II Series 6 Switchboard CBC-3033-B | 3000 Amp Fusible Main | 480Y/277V 3-Phase 4-Wire | NEMA 1 R&G

Siemens FC II Series 6 Switchboard; 3000 amp fusible main switch- cat # CBC-3033-B, 480Y/277 volt, 3 phase, 4 wire, ground fault, NEMA 1 indoor. With (2) ITE vacu-break switch fusible distribution panels. Reconditioned & guaranteed with a one-year warranty.
SKU: M537
Contact us for pricing:

Siemens FC II Series 6 Switchboard FP3034-B | 3000 Amp Main Fusible | 480Y/277V 3-Phase 4-Wire | NEMA 1 R&G

Siemens FC II Series 6 Switchboard; 3000 amp main fusible switch- cat # FP3034-B, 480Y/277 volt, 3 phase, 4 wire, ground fault, NEMA 1 indoor. With (6) fusible switch distribution panels. Reconditioned & guaranteed with a one-year warranty.
SKU: M520
Contact us for pricing:

Siemens FC II Switchboard QA-3033-CBC | 3000 Amp Main Fusible | 480Y/277V 3-Phase 4-Wire | NEMA 1 R&G

Siemens FC II Switchboard; 3000 amp fusible main- cat # QA-3033-CBC, 480Y/277 volt, three phase, four wire, ground fault, NEMA 1 indoor rated, C.T. cabinet. Reconditioned & guaranteed with a one year warranty.
SKU: M090
Contact us for pricing:

Siemens SB1 Switchboard | 3000 Amp Main Lug Only | 480Y/277V 3-Phase 4-Wire | NEMA 1 R&G

Siemens SB1 Switchboard; 3000 amp main lug only, 480Y/277 volt, 3 phase, 4 wire, NEMA 1 indoor rated. With (2) sections of Sentron breaker distribution panels. Reconditioned & guaranteed with a one-year warranty.
SKU: M679
Contact us for pricing:

Siemens SB3 Switchboard | 2500 Amp Main Lug Only | 480Y/277V 3-Phase 4-Wire | NEMA 1 R&G

Siemens SB3 Switchboard; 2500 amp main lug only, 480Y/277 volt, 3 phase, 4 wire, NEMA 1 indoor. With (1) breaker distribution panel. Reconditioned & guaranteed with a one year warranty.
SKU: M603
Contact us for pricing:

Siemens SB3 Switchboard CBC-1233-S | 1200 Amp Fusible Main | 480Y/277V 3-Phase 4-Wire | NEMA 1 R&G

Siemens SB3 Switchboard; 1200 amp fusible main switch- cat # CBC-1233-S, 480Y/277 volt, 3 phase, 4 wire, ground fault, NEMA 1 indoor. Reconditioned & guaranteed with a one-year warranty.
SKU: M359
Contact us for pricing:

Siemens SB3 Switchboard SBS4025 | 2500 Amp Main Breaker | 480Y/277V 3-Phase 4-Wire | NEMA 1 R&G

Siemens SB3 Switchboard; 2500 amp main breaker- cat # SBS4025, 480Y/277 volt, 3 phase, 4 wire, LSIG functions, ground fault, NEMA 1 indoor rated. With (2) Distribution panels. Reconditioned & guaranteed with a one-year warranty.
SKU: M609
Contact us for pricing:

Siemens SB3 Switchboard SBS4032 | 3000 Amp Main Breaker | 480Y/277V 3-Phase 4-Wire | NEMA 1 R&G

Siemens SB3 Switchboard; 3000 amp main breaker- cat # SBS4032, 480Y/277 volt, 3 phase, 4 wire, LSIG functions, ground fault, NEMA 1 indoor rated. With (1) Sentron breaker distribution panel. Reconditioned & guaranteed with a one-year warranty.
SKU: M705
Contact us for pricing:

Siemens SB3 Switchboard SBS4040 | 4000 Amp Main Breaker | 480/277V 3-Phase 4-Wire | NEMA 1 R&G

Siemens SB3 Switchboard; 4000 amp main breaker-cat # SBS4040, 480/277 volt, 3 phase, 4 wire, LSIG functions, ground fault, NEMA 1 indoor rated. With (2) sections of breaker distribution. Reconditioned & guaranteed with a one-year warranty.
SKU: M646
Contact us for pricing:

Siemens SB3 Switchboard WLL2F330 | 3000 Amp Main Breaker | 480Y/277V 3-Phase 4-Wire | NEMA 3R R&G

Siemens SB3 Switchboard; 3000 amp main breaker- cat # WLL2F330, 480Y/277 volt, 3 phase, 4 wire, LSIG functions, ground fault, NEMA 3R outdoor rated. With (1) section of breaker distribution. Reconditioned & guaranteed with a one-year warranty.
SKU: M638
Contact us for pricing:

Square D QED Power Style Switchboard BP03620E | 1600 Amp Main Fusible | 480Y/277V 3-Phase 4-Wire | NEMA 1 R&G

Square D QED Power Style Switchboard; 1600 amp main fusible switch- cat # BP03620E, 480Y/277 volt, ground fault indicator, 3 phase, 4 wire, NEMA 1 indoor. Reconditioned & guaranteed with a one-year warranty.
SKU: M726
Contact us for pricing:

Upgrade Low Voltage Switchgear: New, Refurbished, Obsolete

We don’t just sell Low Voltage Switchgear. We provide tailored solutions by understanding your situation as a trusted partner in identifying what you need. Asking questions like:

What are the Voltage Rating Requirements?

Let’s make sure the switchgear's voltage rating matches the requirements of the electrical system it will be installed in. Low voltage switchgear typically operates at voltages up to 1000V AC or 1500V DC. Beyond this, consider Medium Voltage switchgear.

What is the Maximum Current Rating?

It’s important to know the maximum current that the switchgear can handle safely. This should align with the expected load and short-circuit currents in the system.

Where is the Operating Environment?

Evaluate the environmental conditions where the switchgear will be installed, including temperature, humidity, dust, and corrosive elements. Choose switchgear with appropriate ingress protection (IP) ratings and environmental certifications.

What Type of Protection is Needed?

By knowing this, we can decide whether the application requires protection against overload, short circuit, or both. Select switchgear with built-in protection features such as circuit breakers, fuses, or protective relays as needed.

How Much Space Do You Have:

Consider the physical dimensions and layout of the installation site to ensure the switchgear fits properly and allows for future expansion if necessary.

Which Safety Standards Need to Be Met?

Verifying the switchgear complies with relevant safety standards and certifications such as IEC, ANSI, UL, or other local regulations. This way the equipment meets minimum safety requirements and performance standards.

What About Reliability and Durability?

Look for switchgear from reputable manufacturers known for producing reliable and durable equipment. Consider factors such as component quality, design robustness, and maintenance requirements.

Is Remote Monitoring and Control Needed?

If remote monitoring and control are desired, choose switchgear with compatible communication interfaces (such as Modbus, Profibus, or Ethernet) and software capabilities for seamless integration into the overall control system.

Have You Considered Arc Flash Mitigation?

Evaluate the switchgear's ability to minimize the risk and severity of arc flash incidents through design features such as arc-resistant construction, fast fault-clearing times, and proper equipment labeling.

What About Cost and Total Ownership?

Assess the initial purchase cost along with long-term maintenance, operating costs, and potential energy savings. Consider the total cost of ownership over the switchgear's lifecycle to make an informed investment decision.

 

How Can We Help?

Let us help you choose the right Low Voltage Switchgear Solution with confidence. You have customized low voltage switchgear needs? We'll match voltage levels, load capacity, and fault current ratings, to name a few considerations. Your switchgear has special demands, so our solutions balance upfront costs with long-term value, with each unit undergoing testing to lower your total cost over its lifespan.