Low Voltage Switchgear

While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

ITE/Siemens 2000 Amp 480Y/277 Volt Pringle #CBC-2033-B Main Fusible Panel w/ GFI NEMA 1 R&G

ITE/Siemens FC-1 type panel; 2000 amp rated, 480Y/277 volt, three phase, four wire. Pringle #CBC-2033-B fusible main switch, bottom feed with ground fault, distribution can be added (breaker or fusible), Nema 1 indoor indoor rated. Reconditioned & guaranteed with a one year warranty. Contact EMSCO today to discuss this panel. The distribution can be customized to meet your needs.
SKU: M268
Contact us for pricing:

Siemen Switchboard 2000 Amp Main Lug Only 480Y/277 Volt NEMA 1 R&G

Siemens Switchboard; 2000 amp, main lug only, 480Y/277 volt, 3 phase, 4 wire. With fusible distribution, Nema 1 indoor. Reconditioned & guaranteed with a one year warranty.
SKU: M602
Contact us for pricing:

Siemens 1600 Amp 480Y/277 Volt 3 Phase 4 Wire QA-1633-CBC Main Fusible Panel NEMA 1 R&G

Siemens QA-1633-CBC Main Fusible Panel: 1600 amp, 480Y/277 volt, three phase, four wire, GFI with ground fault, sensor relay, NEMA 1 indoor. Recondition & guaranteed with a one year warranty.
SKU: M230
Contact us for pricing:

Siemens 3000 Amp CBC-3033-B Fusible Main Switchboard 480Y/277 Volt 3Ph 4W GFI NEMA 1 R&G

Siemens fusible switchboard; 3000 amp Pringle switch fusible main, cat# CBC-3033-B, 480 volt, 3 phase, 4 wire, ground fault, NEMA 1 indoor. With ITE vacu-break switch fusible distribution. Reconditioned & guaranteed with a one-year warranty.
SKU: M537
Contact us for pricing:

Siemens 3000 Amp CBC-3033-B Fusible Main Switchboard 480Y/277 Volt 3Ph 4W GFI NEMA 1 R&G

Siemens fusible switchboard; 3000 amp Pringle switch fusible main, cat# CBC-3033-B, 480 volt, 3 phase, 4 wire, ground fault, NEMA 1 indoor. With Pringle mains & ITE vacu-break switch fusible distribution. Reconditioned & guaranteed with a one-year warranty.
SKU: M540
Contact us for pricing:

Siemens 3000 Amp Fusible Main Switchboard 480Y/277 Volt 3Ph 4W GFI W/ Distribution NEMA 1 R&G

Siemens fusible switchboard; 3000 amp Pringle switch fusible main, cat# FP3034-B, 480 volt, 3 phase, 4 wire, ground fault, NEMA 1 indoor. With 2000 amp fusible distribution Pringle switch, & 6 total distribution sections. Reconditioned & guaranteed with a one-year warranty.
SKU: M520
Contact us for pricing:

Siemens 3000 Amp QA-3033-CBC Fusible Main Switchboard 480Y/277 Volt 3Ph 4W GFI NEMA 1 R&G

Siemens fusible switchboard; 3000 amp Pringle switch fusible main, QA-3033-CBC, 480 volt, 3 phase, 4 wire, ground fault, NEMA 1 indoor. With Pringle switch & ITE vacu-break switch fusible distribution. Reconditioned & guaranteed with a one-year warranty.
SKU: M539
Contact us for pricing:

Siemens 3000A 3 Phase 4 Wire 480Y/277V QA-3033-CBC Fusible Main Panel W/ GF NEMA 1 R&G

Siemens 3000 amp, 480Y/277 volt, three phase, four wire. Pringle fused main, QA-3033-CBC with ground fault with C.T. cabinet 2 - sections, Nema 1 indoor rated. Reconditioned & guaranteed with a one year warranty. Contact EMSCO today to discuss this panel. The distribution can be customized to meet your needs.
SKU: M090
Contact us for pricing:

Siemens ITE FCI Switchboard 1600 Amp 480Y/277 Volt 3 Ph 4 W MLO NEMA 1 R&G

Siemens ITE FCI Switchboard; main lug only, 1600 amp max, 480Y/277 volt, 3 phase, 4 wire, NEMA 1 indoor rated. With V7 distribution switches. Reconditioned & guaranteed with a one-year warranty.
SKU: M647
Contact us for pricing:

Siemens SB3 Switchboard 1200 Amp CBC-1233-S Fusible Main 480Y/277 Volt W/ Ground Fault NEMA 1 R&G

Siemens SB3 Switchboard; 1200 amp, CBC-1233-S fusible main, 480Y/277 volt with ground fault, Nema 1 indoor. Reconditioned & guaranteed with a one year warranty.
SKU: M359
Contact us for pricing:

Siemens SB3 Switchboard 2500 Amp 480Y/277 Volt 3 Ph 4W NEMA 1 R&G

Siemens SB3 Switchboard; 2500 amp, cat# SBS4025, 480Y/277 volt, 3 phase, 4 wire, LSIG functions, ground fault, NEMA 1 indoor rated. Reconditioned & guaranteed with a one-year warranty.
SKU: M609
Contact us for pricing:

Siemens SB3 Switchboard 3000 Amp Main Breaker 480Y/277 Volt 3 Ph 4 W NEMA 3R R&G

Siemens SB3 Switchboard; 3000 amp main breaker; 480Y/277 volt, 3 phase, 4 wire, LSIG functions, NEMA 3R outdoor rated. With 1 section of breaker distribution. Reconditioned & guaranteed with a one-year warranty.
SKU: M638
Contact us for pricing:

Siemens Switchboard 2500 Amp Main Lug Only 480Y/277 Volt NEMA 1 R&G

Siemens Switchboard; 2500 amp, main lug only, 480Y/277 volt, 3 phase, 4 wire. With breaker distribution, Nema 1 indoor. Reconditioned & guaranteed with a one year warranty.
SKU: M603
Contact us for pricing:

Siemens Switchboard 3000 Amp Main Lug Only 480Y/277 Volt NEMA 1 R&G

Siemens Switchboard; 3000 amp, main lug only, 480Y/277 volt, 3 phase, 4 wire. With fusible distribution, Nema 1 indoor. Reconditioned & guaranteed with a one year warranty.
SKU: M604
Contact us for pricing:

Siemens Switchboard 4000 Amp SBS4040 Main Breaker 480/277 Volt 3 Ph 4 W NEMA 1 R&G

Siemens Switchboard; 4000 amp main breaker, type SBS4040, 480/277 volt, 3 phase, 4 wire, NEMA 1 indoor rated, LSIG functions. With 2 sections of breaker distribution. Reconditioned & guaranteed with a one-year warranty.
SKU: M646
Contact us for pricing:

Upgrade Low Voltage Switchgear: New, Refurbished, Obsolete

We don’t just sell Low Voltage Switchgear. We provide tailored solutions by understanding your situation as a trusted partner in identifying what you need. Asking questions like:

What are the Voltage Rating Requirements?

Let’s make sure the switchgear's voltage rating matches the requirements of the electrical system it will be installed in. Low voltage switchgear typically operates at voltages up to 1000V AC or 1500V DC. Beyond this, consider Medium Voltage switchgear.

What is the Maximum Current Rating?

It’s important to know the maximum current that the switchgear can handle safely. This should align with the expected load and short-circuit currents in the system.

Where is the Operating Environment?

Evaluate the environmental conditions where the switchgear will be installed, including temperature, humidity, dust, and corrosive elements. Choose switchgear with appropriate ingress protection (IP) ratings and environmental certifications.

What Type of Protection is Needed?

By knowing this, we can decide whether the application requires protection against overload, short circuit, or both. Select switchgear with built-in protection features such as circuit breakers, fuses, or protective relays as needed.

How Much Space Do You Have:

Consider the physical dimensions and layout of the installation site to ensure the switchgear fits properly and allows for future expansion if necessary.

Which Safety Standards Need to Be Met?

Verifying the switchgear complies with relevant safety standards and certifications such as IEC, ANSI, UL, or other local regulations. This way the equipment meets minimum safety requirements and performance standards.

What About Reliability and Durability?

Look for switchgear from reputable manufacturers known for producing reliable and durable equipment. Consider factors such as component quality, design robustness, and maintenance requirements.

Is Remote Monitoring and Control Needed?

If remote monitoring and control are desired, choose switchgear with compatible communication interfaces (such as Modbus, Profibus, or Ethernet) and software capabilities for seamless integration into the overall control system.

Have You Considered Arc Flash Mitigation?

Evaluate the switchgear's ability to minimize the risk and severity of arc flash incidents through design features such as arc-resistant construction, fast fault-clearing times, and proper equipment labeling.

What About Cost and Total Ownership?

Assess the initial purchase cost along with long-term maintenance, operating costs, and potential energy savings. Consider the total cost of ownership over the switchgear's lifecycle to make an informed investment decision.

 

How Can We Help?

Let us help you choose the right Low Voltage Switchgear Solution with confidence. You have customized low voltage switchgear needs? We'll match voltage levels, load capacity, and fault current ratings, to name a few considerations. Your switchgear has special demands, so our solutions balance upfront costs with long-term value, with each unit undergoing testing to lower your total cost over its lifespan.