Westinghouse

Please note that our available online inventory is only a sampling of our available in-stock inventory. If you cannot locate the product you need, please call us at 1-800-328-1842. Our sales team will be happy to find it for you.

150DHP500 Westinghouse 15KV 1200A EO/DO Air Circuit Breaker

Westinghouse 150DHP500 air circuit breaker; 1200 amp, 15 KV, three pole. Control: 125 volt DC, electrically operated, draw-out. Sold used as-is.
SKU: 150DHP500 - EMSCO # 19556

150DHP500 Westinghouse 15KV 1200A EO/DO Air Circuit Breaker

Westinghouse 150DHP500 air circuit breaker; 1200 amp, 15 KV, three pole, control: 48 volt DC, electrically operated, draw-out. Sold used as-is.
SKU: 150DHP500 - EMSCO # 19557

150DHP500 Westinghouse 15KV 1200A EO/DO Air Circuit Breaker

Westinghouse 150DHP500 air circuit breaker; 1200 amp, 15 KV rated, three pole. Control: 48 volt DC electrically operated, draw-out. Sold used as is.
SKU: 150DHP500-EMSCO#19929

150DHP500 Westinghouse 15KV 1200A EO/DO Air Circuit Breaker

Westinghouse 150DHP500 air circuit breaker; 1200 amp, 15 KV rated, three pole. Control: 48 volt DC, electrically operated, draw-out. Sold used as is.
SKU: 150DHP500 - EMSCO #19933

150DHP500 Westinghouse 15KV 1200A EO/DO Air Circuit Breaker

Westinghouse 150DHP500 air circuit breaker; 1200 amp, 15 KV rated, three pole. Control: 48 volt DC, electrically operated, draw-out. Used as is.
SKU: 150DHP500 - EMSCO #19934

150DHP500 Westinghouse 15KV 1200A EO/DO Air Circuit Breaker

Westinghouse 150DHP500 circuit breaker; 1200 amp, 15 KV, three pole, control: 48 volt DC, electrically operated, draw-out, sold used as-is.
SKU: 150DHP500 - EMSCO#19558

150DHP500 Westinghouse 15KV 1200A EO/DO Porcel Line Air Breaker

Westinghouse 150DHP500 Porcel Line Breaker; 1200 amp rated; KV: 13.8 max. design KV: 15, BIL-KV: 95, cycles: 60, rated MVA 500, max. amps 25,000, MOM. amps 40,000. Electrically operated, draw-out, closing voltage range: 105-130 VDC, trip voltage : 125 VDC. Used as-is.
SKU: 150DHP500 EMSCO# 19551

150DHP500 Westinghouse 15KV 1200A EO/DO Porcel Line Air Breaker

Westinghouse 150DHP500 Porcel Line Breaker; 1200 amp rated, KV: 13.8 max. design KV: 15, BIL-KV: 95, cycles : 60, rated MVA 500, max. amps 25,000, mom. amps 60,000. Electrically Operated, draw-out, closing voltage range: 40-50 VDC, trip voltage : 48 VDC, motor volts: 48 VDC. Used as-is.
SKU: 150DHP500 EMSCO# 19552

150DHP500 Westinghouse Air Breaker 1200A 15KV EO/DO

Westinghouse 150DHP500 Air Breaker; 1200 amp, 15 KV, electrically operated, draw-out, #22735, closing range: 40-50 DC, trip voltage: 48 DC. Used electrically OK.
SKU: 150DHP500-EO-DO-#22735

150DHP500 Westinghouse Air Breaker 1200A 15KV EO/DO

Westinghouse 150DHP500 Air Breaker; 1200 amp, 15 KV, electrically operated, draw-out, #22736, closing range: 40-50 DC, trip voltage: 48 DC. Used electrically OK.
SKU: 150DHP500-EO-DO-#22736

150DHP500 Westinghouse Air Breaker 1200A 15KV EO/DO

Westinghouse 150DHP500 Air Breaker; 1200 amp, 15 KV, electrically operated, draw-out, #22737, closing range: 40-50 DC, trip voltage: 48 DC. Used electrically OK.
SKU: 150DHP500-EO-DO-#22737

150DHP500 Westinghouse Air Breaker 1200A 15KV EO/DO

Westinghouse 150DHP500 Air Breaker; 1200 amp, 15 KV, electrically operated, draw-out, #22738, closing range: 40-50 DC, trip voltage: 48 DC. Used electrically OK.
SKU: 150DHP500-EO-DO-#22738

150DHP500 Westinghouse Air Breaker 1200A 15KV EO/DO

Westinghouse 150DHP500 Air Breaker; 1200 amp, 15 KV, electrically operated, draw-out, #22739, closing range: 40-50 DC, trip voltage: 48 DC. Used electrically OK.
SKU: 150DHP500-EO-DO-#22739

150DHP500 Westinghouse Air Breaker 1200A 15KV EO/DO

Westinghouse 150DHP500 Air Breaker; 1200 amp, 15 KV, electrically operated, draw-out, #22740, closing range: 40-50 DC, trip voltage: 48 DC. Used electrically OK.
SKU: 150DHP500-EO-DO-#22740

150DHP500 Westinghouse Air Breaker 1200A 15KV EO/DO

Westinghouse 150DHP500 Air Breaker; 1200 amp, 15 KV, electrically operated, draw-out, #22741, closing range: 40-50 DC, trip voltage: 48 DC. Used electrically OK.
SKU: 150DHP500-EO-DO-#22741

150DHP500 Westinghouse Air Breaker 1200A 15KV EO/DO

Westinghouse 150DHP500 Air Breaker; 1200 amp, 15 KV, electrically operated, draw-out, #22742, closing range: 40-50 DC, trip voltage: 48 DC. Used electrically OK.
SKU: 150DHP500-EO-DO-#22742

150VCP-T 16 Cutler Hammer 1200A 15KV EO/DO Vacuum Circuit Breaker w/ Cubicle

Cutler Hammer Vacuum Circuit Breaker; 150 VCP-T 16 1200 amp, 15 KV RMS, 60 Hz, 600 amp RMS. Continuous current Digitrip 520V, 5V, LSIG with 600A Rating Plug. 95 kV Peak Lightning Impulse Withstand Voltage Operating Duty, Cycle: O-0.3s-CO-15s-CO, Interr. Time: 50 RMS, Short Circuit Current: 16 KA RMS, D.C component: 54%, Short Time Current Duration: 2 sec. Electrically operated, Motor volts: 208-254 VAC 1.8A, Close Voltage: 208-254 VAC 1.8A, Trip-1 Voltage: 240 VAC 50/60hz, Capacitor Trip, draw-out with Cubicle: Type VCP-T/T-VAC Cassette. Used Electrically Okay.
SKU: 150VCPT16#22255

150VCP-W500 Westinghouse 1200A 15KV EO/DO Vacuum Circuit Breaker

Cutler Hammer / Westinghouse Vacuum Circuit Breaker; 150VCP-W500, 1200 amp, 15 KV, 60 Hz. Rtd S-C Current: 18 KA, K-Factor: 1.30 Ind, Interr. Time: 5 Cycles, C&L Current: 37 KA. Electrically operated, Motor volts: 125 AC/DC, Close Current: 6.6A, Voltage Range: 104-127 VAC, Trip-1 Amps: 6.6, Voltage Range: 20-56 VDC, draw-out. Used Electrically Okay.
SKU: 150VCPW500#20960

150VCP-W500 Westinghouse 1200A 15KV EO/DO Vacuum Circuit Breaker

Cutler Hammer / Westinghouse Vacuum Circuit Breaker; 150VCP-W500, 1200 amp, 15KV, 60 Hz. Rtd S-C Current: 18 KA, K-Factor 1.30 Ind, Interr. Time: 5 Cycles, C&L Current: 37 KA. Electrically operated, Motor volts: 125 AC/DC, Close Current: 6.6A, Voltage Range: 104-127 VAC, Trip-1 Amps: 6.6, Voltage Range: 20-56 VDC, draw-out. Used Electrically Okay.
SKU: 150VCPW500#20962

150VCP-W500 Westinghouse 1200A 15KV EO/DO Vacuum Circuit Breaker

Cutler Hammer / Westinghouse Vacuum Circuit Breaker; 150VCP-W500 1200 amp, 15 KV, 60 Hz. Rtd S-C Current: 18 KA, K-Factor: 1.30 Ind, Interr. Time: 5 Cycles, C&L Current: 37 KA. Electrically operated, Motor Volts: 125 AC/DC, Close Current: 6.6A, Voltage Range: 104-127 VAC, Trip-1 Amps: 6.6, Voltage Range: 20-56 VDC, draw-out. Used Electrically Okay.
SKU: 150VCPW500#20963