Vacuum Breakers

Please note that our available online inventory is only a sampling of our available in-stock inventory. If you cannot locate the product you need, please call us at 1-800-328-1842. Our sales team will be happy to find it for you.

150 VCP-18WR500 Westinghouse Replacement for GE FK-255 1200A 15KV EO/DO Vacuum Circuit Breaker

Westinghouse Vacuum Circuit Breaker 150VCP-W500 Replacement Unit for GE FK-255 FK-255-VUR; 1200 amp, 15KV, 60 Hz, BIL: 95KV, Rtd S-C Current: 18 KA, K-Factor: 1.30 Ind, Interr. Time: 5 Cycles, C&L Current: 62 Crest. Electrically operated, Motor Volts: 125V AC/DC, Close Amps: 6.6, Volt Range: 100-140 DC, Trip-1 Amps: 6.6A, Voltage Range: 70-140 VDC, Draw-out. Used Electrically Okay.
SKU: 150VCP-18WR500 #20621

150 VCP-W 500 Westinghouse Vacuum Breaker 1200A 15KV EO/DO

150 VCP-W 500 Westinghouse Vacuum Breaker; 1200 amps, 15 KV. Electrically operated, draw-out, short circuit amps: 18 KA, motor volts: 125 AC/DC, close amps: 6.6, volt range: 104-127 AC. Used Electrically OK.
SKU: 150VCP-W500-EO-DO-#22703

150 DHP-VR-1000 Cutler-Hammer Vacuum Breaker 1200A 15KV EO/DO

150 DHP-VR-1000 Cutler-Hammer Vacuum Breaker; 1200 amps, 15 KV. Electrically operated, draw-out, 125 VDC motor volts.
SKU: 150DHP-VR-1000-#22877

150 DHP-VR-1000 Cutler-Hammer Vacuum Breaker 1200A 15KV EO/DO

150 DHP-VR-1000 Cutler-Hammer Vacuum Breaker; 1200 amps, 15 KV. Electrically operated, draw-out, 125 VDC motor volts.
SKU: 150DHP-VR-1000-#22876

150 DHP 500U-SF6VRF Westinghouse FS-6 Retrofit Vacuum Conversion 15KV 1200A

150 DHP 500U-SF6VRF Westinghouse FS-6 Retrofit Vacuum Conversion; 1200 amps, 15 KV, Short circuit amps: 37 KA, Closing volts: 125 VDC, Charging motor: 125 VDC.
SKU: 150DHP500U-SF6VRF-#22750

V5D8233Y000 Sq D VR 2000 Amp 15KV EO/DO Breaker

Square D Medium Voltage Circuit Breaker Type VR Catalog #V5D8233Y000; 2000 amp, 15 KV Rated. Electrically operated, draw-out, Close Coil Voltage Range: 100-140 VDC, Tripping Coil Voltage Range: 70-140 VDC. Used Electrically OK.
SKU: V5D8233Y000 #20519

FKR-255 GE converted to Merlin Gerin Fluarc FG 2 15KV 1200A Vacuum Breaker

FKR-255 GE converted to Merlin Gerin Fluarc FG 2; 15 KV, 1200 amp vacuum breaker. Electrically operated, draw-out, rated short circuit current: 37 KA.
SKU: Fluarc-FG2-EO/DO-#22785

FKR-255 GE converted to Merlin Gerin Fluarc FG 2 15KV 1200A Vacuum Breaker EO/DO

FKR-255 GE converted to Merlin Gerin Fluarc FG 2; 1200 amps, 15 KV, vacuum breaker. Electrically operated, draw-out, rated short circuit current: 37 KA.
SKU: Fluarc-FG2-EO/DO-#22786

FKR-255 GE converted to Merlin Gerin Fluarc FG 2 15KV 1200A Vacuum Breaker EO/DO

FKR-255 GE converted to Merlin Gerin Fluarc FG 2; 15 KV, 1200 amp, vacuum breaker. Electrically operated, draw-out, rated short circuit current: 37 KA.
SKU: Fluarc-FG2-EO/DO-#22788

FKR-255 GE converted to Merlin Gerin Fluarc FG 2 15KV 1200A Vacuum Breaker

FKR-255 GE converted to Merlin Gerin Fluarc FG 2; 15 KV, 1200 amp, vacuum breaker. Electrically operated, draw-out, rated short circuit current: 37 KA. Used Electrically OK.
SKU: Fluarc-FG2-EO/DO-#22789

FKR-255 GE converted to Merlin Gerin Fluarc FG 2 15KV 1200A Vacuum Breaker

FKR-255 GE converted to Merlin Gerin Fluarc FG 2; 15 KV, 1200 amp, vacuum breaker. Electrically operated, draw-out, rated short circuit current: 37 KA. Used Electrically OK.
SKU: Fluarc-FG2-EO/DO-#22790

FKR-255 GE converted to Merlin Gerin Fluarc FG 2 15KV 1200A Vacuum Breaker

FKR-255 GE converted to Merlin Gerin Fluarc FG 2; 15 KV, 1200 amp, vacuum breaker. Electrically operated, draw-out, rated short circuit current: 37 KA. Used Electrically OK.
SKU: Fluarc-FG2-EO/DO-#22791

FKR-255 GE converted to Merlin Gerin Fluarc FG 2 15KV 1200A Vacuum Breaker EO/DO

FKR-255 GE converted to Merlin Gerin Fluarc FG 2; 15 KV, 1200 amp, vacuum breaker. Electrically operated, draw-out, rated short circuit current: 37 KA. Used Electrically OK.
SKU: Fluarc-FG2-EO/DO-#22792

150 VCP-18WR500 Westinghouse Replacement for GE FK-255 1200A 15KV EO/DO Vacuum Circuit Breaker

Westinghouse Vacuum Circuit Breaker 150VCP-W500 Replacement Unit for GE FK-255 FK-255-VUR; 1200 amp, 15KV, 60 Hz. BIL: 95 KV, Rtd S-C Current: 18 KA, K-Factor: 1.30 Ind, Interr. Time: 5 cycles, C&L Current: 62 Crest. Electrically operated, Motor volts: 125 volt AC/DC, Close amps: 6.6 volt, Range: 100-140 DC, Trip-1 Amps: 6.6A, Voltage range: 70-140 VDC, draw-out. Used Electrically Okay.
SKU: 150VCP-18WR500 #20622

150 VCP-18WR500 Westinghouse Replacement for GE FK-255 1200A 15KV EO/DO Vacuum Circuit Breaker

Westinghouse 150 VCP-18WR500 Vacuum Circuit Breaker; 150VCP-W500 Replacement Unit for GE FK-255. FK-255-VUR. 1200 amp, 15 KV, 60 Hz, BIL: 95 KV, Rtd S-C Current: 18 KA, K-Factor: 1.30 Ind, Interr. Time: 5 Cycles, C&L Current: 62 Crest. Electrically operated, Motor Volts: 125 volt AC/DC, Close Amps: 6.6, Volt Range: 100-140 DC, Trip-1 Amps: 6.6A, Voltage Range: 70-140 VDC, draw-out. Used Electrically Okay.
SKU: 150VCP-18WR500 #20628

150 VCP-18WR500 Westinghouse Replacement for GE FK-255 1200A 15KV EO/DO Vacuum Circuit Breaker

Westinghouse Vacuum Circuit Breaker; 150VCP-W500 Replacement Unit for GE FK-255 FK-255-VUR. 1200 amp, 15 KV, 60 Hz, BIL: 95 KV, Rtd S-C Current: 18 KA, K-Factor: 1.30 Ind, Interr Time: 5 Cycles, C&L Current: 62 Crest. Electrically operated, Motor volts: 125 volt AC/DC, Close Amps: 6.6, Volt Range: 100-140 DC, Trip-1 Amps: 6.6, Voltage Range: 70-140 VDC, draw-out. Used Electrically Okay.
SKU: 150VCP-18WR500 #20629

150 VCP-W 500 Westinghouse Vacuum Breaker 1200A 15KV EO/DO

Westinghouse 150 VCP-W 500 Vacuum Breaker; 1200 amps, 15 KV. Electrically operated, draw-out, short circuit amps: 18 KA, motor volts: 125 AC/DC, close amps: 6.6, volt range: 104-127 AC. Used Electrically OK.
SKU: 150VCP-W500-EO-DO-#22731

150VCP-T 16 Cutler Hammer 1200A 15KV EO/DO Vacuum Circuit Breaker w/ Cubicle

Cutler Hammer Vacuum Circuit Breaker; 150 VCP-T 16 1200 amp, 15 KV RMS, 60 Hz, 600 amp RMS. Continuous current Digitrip 520V, 5V, LSIG with 600A Rating Plug. 95 kV Peak Lightning Impulse Withstand Voltage Operating Duty, Cycle: O-0.3s-CO-15s-CO, Interr. Time: 50 RMS, Short Circuit Current: 16 KA RMS, D.C component: 54%, Short Time Current Duration: 2 sec. Electrically operated, Motor volts: 208-254 VAC 1.8A, Close Voltage: 208-254 VAC 1.8A, Trip-1 Voltage: 240 VAC 50/60hz, Capacitor Trip, draw-out with Cubicle: Type VCP-T/T-VAC Cassette. Used Electrically Okay.
SKU: 150VCP-T16 #22255

150VCP-W500 Cutler-Hammer 1200A 15KV EO/DO Vacuum Circuit Breaker

Cutler-Hammer Vacuum Circuit Breaker 150VCP-W500; 1200 amp, 15KV, 60 Hz. Rtd S-C Current: 18 KA, Volt Range K-Factor: 1.30 Ind, Interr. Time: 5 Cycles, C&L Current: 62 kA. Peak. Electrically operated, Motor Volts: 48 VDC, Close Current: 15.5A, Voltage Range: 38-56 VDC, Trip-1 Current: 15.5A, Voltage Range: 28-56 VDC, Trip-2 Current: Cap Trip Voltage Range: 240V AC, draw-out. Used Electrically Okay.
SKU: 150VCP-W500 #20522

150VCP-W500 Westinghouse 1200A 15KV EO/DO Vacuum Circuit Breaker

Cutler Hammer / Westinghouse Vacuum Circuit Breaker; 150VCP-W500, 1200 amp, 15 KV, 60 Hz. Rtd S-C Current: 18 KA, K-Factor: 1.30 Ind, Interr. Time: 5 Cycles, C&L Current: 37 KA. Electrically operated, Motor volts: 125 AC/DC, Close Current: 6.6A, Voltage Range: 104-127 VAC, Trip-1 Amps: 6.6, Voltage Range: 20-56 VDC, draw-out. Used Electrically Okay.
SKU: 150VCP-W500 #20960

Used and Refurbished Vacuum Breakers

EMSCO has been specializing in used and refurbished vacuum breaker options for over 72 years. Need help identifying the vacuum breakers you need to replace, use our website to find it.