Molded & Insulated Case Circuit Breakers

Currently shopping by:
  • Fixed Mount or Draw Out: Fixed Mount
Remove Filter
While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

PHF3616001386 Square D Breaker 2000 Amp 600 VAC M/O F/M

Square D PHF3616001386 circuit breaker; 2000 amp frame, 600 volt AC, 3 pole. With 1600 amp rating tower, shunt trip- 24 VDC, auxiliary switch- 15.1A @ 120-250 VAC, .5A @125 VDC, .25A @ 250 VDC, manually operated (M/O), fixed mount (F/M), used tested with report.
SKU: MCCB1759

PHF2036 Square D Breaker 2000 Amp 600 VAC M/O F/M

Square D PHF2036 circuit breaker; 2000 amp, 600 volt AC, 3 pole. With 800 amp rating tower, manually operated (M/O), fixed mount (F/M), used tested with report.
SKU: MCCB1645

PHF2036 Square D Breaker 2000 Amp 600 VAC M/O F/M

Square D PHF2036 circuit breaker; 2000 amp, 600 volt AC, 3 pole. With 1000 amp rating tower cat.# PA-31000-RC, manually operated (M/O), fixed mount (F/M), used tested with report.
SKU: MCCB1651

PHF2036 Square D Breaker 2000 Amp 600 VAC M/O F/M

Square D PHF2036 circuit breaker; 2000 amp, 600 volt AC, 3 pole. With 800 amp rating tower, manually operated (M/O), fixed mount (F/M), used tested with report.
SKU: MCCB1642

PAF2036 Square D Breaker 2000 Amp 600 VAC M/O F/M

Square D PAF2036 breaker; 2000 amp, 600 volt AC, 3 pole, 1200 amp rating tower, manually operated (M/O), fixed mount (F/M), used tested with report.
SKU: MCCB1806
Contact us for pricing:

PAF361600F Square D Breaker 1600 Amp 600 VAC M/O F/M

Square D PAF-361600-F circuit breaker; 1600 amp, 600 volt AC, 3 pole. With 1400 amp trip unit, manually operated (M/O), fixed mount (F/M), used tested with report.
SKU: MCCB1572

PAF362000DC1226 Square D "DC" Breaker 2000 Amp 500 VDC M/O F/M

Square D PAF362000DC1226 "DC" breaker ** 2000 amp, 500 volt DC, 3 pole. With auxiliary switch, under voltage trip- 24 VDC, manually operated (M/O), fixed mount (F/M), used tested with report. ** Missing Handle
SKU: MCCB1595

Square D (Schneider) Masterpact NW50H Circuit Breaker 5000 Amp 600 VAC E/O F/M

Square D (Schneider) NW50H MasterPact circuit breaker: cat.#YG3LLX64A3SCBBXXXXY002 (Schneider) cat.# 244-9977, 5000 amp, three pole, 600 volt AC, 5000 amp rated. With Micrologic 6.0P trip unit with LSIG functions, ground fault protection, 100ka @ 480 volt, Modbus communication, spring charging motor -  24 VDC, shunt trip - 24 VAC/24 VDC, closing coil - 24 VAC/24 VDC, electrically operated (E/O), fixed mount (F/M), used tested with report.
SKU: MCCB1532

Square D (Schneider) Masterpact NW50H Circuit Breaker 5000 Amp 600 VAC E/O F/M

Square D (Schneider) NW50H MasterPact breaker: cat# YG3LLX64A3SCBBXXXXY002 (Schneider), cat.# 244-9977, 5000 amp, 5000 amp rated, 600 volt AC, three pole. With Micrologic 6.0P trip unit with LSIG functions, ground fault protection, 100ka @ 480 volt, Modbus communication, spring charging motor- 24 VDC, shunt trip - 24 VAC/24 VDC, closing coil - 24 VAC/24 VDC, electrically operated (E/O), fixed-mount (F/M), used tested with report.
SKU: MCCB1533

PB31600PRF Westinghouse Tri-Pac Breaker 1200 Amp 600 VAC M/O F/M

Westinghouse PB31600PRF Tri-Pac breaker **1200 amp, 600 volt AC, 3 pole. With 1200 amp trip unit cat.# 5683D87G18, manually operated (M/O), fixed mount (F/M), used tested with report ** broken handle.
SKU: MCCB1549

PB32500F Westinghouse Breaker 2500 Amp 600 VAC M/O F/M

Westinghouse PB32500F Selectronic circuit breaker; 2500 amp, 600 volt AC, 3 pole. With 1800 amp rating plug, manually operated (M/O), fixed mount (F/M), used tested with report.
SKU: MCCB1654

PB32500F Westinghouse Breaker 2500 Amp 600 VAC M/O F/M

Westinghouse PB32500F Selectronic breaker; 2500 amp, 600 volt AC, 3 pole. With 1200 amp rating plug, shunt trip- 120 VAC, manually operated (M/O), fixed mount (F/M), used tested with report.
SKU: MCCB1657

PC32000FM Westinghouse Breaker 2000 Amp 600 VAC M/O F/M

Westinghouse PC32000FM circuit breaker; cat# PC32000FM, 2000 amp, 600 volt AC, 3 pole. With 2000 amp rating plug, shunt trip, (3) auxiliary switches, manually operated (M/O), fixed mount (F/M), used tested with report.
SKU: MCCB1738

PHF2036 Square D Breaker 2000 Amp 600 VAC M/O F/M

Square D PHF2036 circuit breaker; 2000 amp, 600 VAC, 3 pole, manually operated, fixed mount, used tested with report.
SKU: MCCB1634

PHF2036 Square D Breaker 2000 Amp 600 VAC M/O F/M

Square D PHF2036 circuit breaker; 2000 amp, 600 volt AC, 3 pole. With 800 amp rating tower, manually operated (M/O), fixed mount (F/M), used tested with report.
SKU: MCCB1643

PHF2036 Square D Breaker 2000 Amp 600 VAC M/O F/M

Square D PHF2036 circuit breaker; 2000 amp, 600 volt AC, 3 pole. With 800 amp rating tower, manually operated (M/O), fixed mount (F/M), used tested with report.
SKU: MCCB1644

RD316T35W Cutler-Hammer Breaker RD 65K 1600 Amp 600 VAC MO/FM

Cutler-Hammer RD316T35W Breaker Type RD 65K; 1600 amp, 600 VAC, 3 pole. Digitrip RMS310 cat# RES1600LSG with 1600 amp rating plug cat# 16RES16T, auxiliary switch cat# A2X6RPK. Manually operated, fixed-mount. Used tested with report.
SKU: MCCB1829

SPB100 Cutler-Hammer Breaker 3000 Amp 600 VAC 3 Pole MO/FM LSIG

Cutler-Hammer SPB100 Breaker; 3000 amp, 600 volt AC, 3 pole, manually operated (M/O), fixed mount (F/M). With Digitrip RMS510 cat # S56LSIG (D), LSIG functions, ground fault, 3000 amp rating plug cat # RP6S30A300, shunt trip cat # SPBST125D, auxiliary switch cat# SPBAUX304, used tested with report.
SKU: MCCB1831
Contact us for pricing:

TP88SS GE Power Break Breaker 800 Amp 600 VAC LSIG MO/FM

General Electric TP88SS Power Break Circuit Breaker; 800 amp, 600 volt AC, 3 pole. With Micro Versa Trip RMS-9 cat# TS20LSIGT2, LSIG functions, ground fault, 600 amp rating plug cat# TR8S600, breaker carriage style # PB16SM, manually operated (M/O), fixed mount (F/M), used tested with report.
SKU: MCCB1833
Contact us for pricing:

TPSS4612SGB GE Power Break Breaker 1200 Amp 600 VAC LSIG MO/FM

General Electric TPSS4612SGB Power Break Circuit Breaker; 1200 amp, 600 volt AC, 3 pole. With Solid state Versa Trip, LSIG functions, ground fault, manually operated (M/O), fixed mount (F/M). Used tested with report.
SKU: MCCB1834
Contact us for pricing:

New, Used, and Tested Molded & Insulated Case Circuit Breakers

EMSCO has been specializing in used and refurbished molded & insulated case circuit breakers for over 72 years.


Why Choose EMSCO for Molded Case or Insulated Case Circuit Breakers?

Want to match and replace your existing breakers? End the hassle of retrofitting your electrical system. Our extensive inventory includes a variety of Molded Case Circuit Breakers (MCCBs) and Insulated Case Circuit Breakers that are designed to seamlessly match and replace your existing breakers by brand, amp rating, voltage, frame size, or model.

 

New and Refurbished Products in Stock

We understand that budgets and preferences differ, so we give you the option of selecting between new and refurbished MCCBs or Insulated Case Breakers, both of which are readily available in our inventory. Choose brand-new circuit breakers for maximum performance and longevity, or look into our refurbished options, which have been rigorously tested and reconditioned to meet industry standards.

 

Popular Brands and Common Configurations

Our shelves are stocked with breakers from the most trusted and popular brands in the industry, ensuring you have access to dependable products. You'll find common configurations, such as different frame sizes and voltage ratings, making it simple to find the right circuit protection for your application.

 

Avoiding Costly Operational Downtime

Downtime can be an expensive situation. Our circuit protection products are designed for high performance and durability. You can avoid costly operational downtime due to electrical failures by using our fully-tested Molded Case or Insulated Case breakers. Our products provide reliable power and superior equipment protection.

 

Electrical Testing Equipment Certifying Quality and Performance

When it comes to the dependability and safety of your electrical systems, we leave nothing to chance. Our breakers are rigorously tested using current testing equipment to ensure that they meet or exceed industry standards. This ensures that your electrical installations are safe and efficient.

  • Overcurrent Protection: We verify that your breakers provide accurate overcurrent protection, guaranteeing the safety of your electrical systems.
  • Trip Time: We measure the time it takes for breakers to respond to overcurrent conditions, ensuring it operates within the specified trip time.
  • Short-Circuit Withstand Capacity: Our testing evaluates the breaker’s ability to withstand short-circuit currents, preventing damage and maintaining safety.
  • Interrupting Capacity: We determine the MCCB's capability to interrupt fault currents, ensuring the utmost protection for your electrical system.

 

Molded Case Circuit Breaker Specifications

A sample table of ampere ratings, corresponding voltage ratings, and frame sizes for molded case circuit breakers is shown below. Please keep in mind that frame sizes and ratings can differ between manufacturers and models. For precise details on a specific MCCB, always refer to the manufacturer's specifications.

 

Frame Size

Ampere Rating

Voltage Rating

A

15A

120V, 240V

A

20A

120V, 240V

B

30A

120V, 240V, 480V

B 50A 120V, 240V, 480V
C 60A 240V, 480V
C 100A 240V, 480V
D 150A 240V, 480V, 600V
D 200A 240V, 480V, 600V
E 250A 240V, 480V, 600V
E 300A 240V, 480V, 600V
F 400A 240V, 480V, 600V
F 600A 240V, 480V, 600V
G 800A 240V, 480V, 600V
G 1200A 240V, 480V, 600V
H 1600A 240V, 480V, 600V

 

This table is a sample representation of frame sizes, ampere ratings, and voltage ratings for Molded Case Circuit Breakers, not an exhaustive list.

 

Molded case circuit breakers (MCCBs) and insulated case circuit breakers (ICCBs) are two distinct types of circuit protection devices used in electrical systems. Both serve the purpose of interrupting electrical currents in case of faults or overloads, but they differ in construction, application, and performance characteristics. Need Help Now? Call 800-328-1842.