Molded & Insulated Case Circuit Breakers

While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

GE Power Break TC2020TTR Circuit Breaker 2000 Amp 600 Volt AC

General Electric Power Break TC2020TTR Circuit Breaker; 2000 amp, 600 volt AC, 3 pole. With MicroVersaTrip plus trip unit cat# C220LSIG, LSIG functions, ground fault, 2000 amp rating plug cat# TR20B2000. Used tested with report.
SKU: MCCB2053
Contact us for pricing:

General Electric Power Break TCYY9640 Circuit Breaker 4000 Amp 600 Volt AC 500 Volt DC M/O F/M Surplus

General Electric Power Break TCYY9640 Circuit Breaker; 4000 amp, 600 volt AC, 500 volt DC, 3 pole, manually operated (M/O), fixed-mount (F/M). New Surplus
SKU: MCCB2103
Contact us for pricing:

General Electric PowerBreak TCYY9640 Circuit Breaker 4000 Amp 600 Volt AC 500 Volt DC M/O F/M Surplus

General Electric PowerBreak Circuit Breaker; cat# TCYY9640, 4000 amp, 600 volt AC, 500 volt DC, 3 pole, manually operated (M/O), fixed-mount (F/M). New Surplus.
SKU: MCCB2102
Contact us for pricing:

KDC2100 Cutler-Hammer Circuit Breaker

Cutler-Hammer KDC2100 circuit breaker; 100 amp, 600 volt, two pole, 100 kAlC @ 480 volt AC, used electrically OK.
SKU: KDC2100
Contact us for pricing:

KDC2125 Cutler-Hammer Circuit Breaker

Cutler-Hammer KDC2125 circuit breaker; 125 amp, 600 volt, two pole, 100 kAlC @ 480 volt AC, used electrically OK.
SKU: KDC2125
Contact us for pricing:

KDC2150 Cutler-Hammer Circuit Breaker

Cutler-Hammer KDC2150 circuit breaker; 150 amp, 600 volt, two pole, 100 kAlC @ 480 volt AC, used electrically OK.
SKU: KDC2150
Contact us for pricing:

KDC2175 Cutler-Hammer Circuit Breaker

Cutler-Hammer KDC2175 circuit breaker; 175 amp, 600 volt, two pole, 100 kAlC @ 480 volt AC, used electrically OK.
SKU: KDC2175
Contact us for pricing:

KDC2200 Cutler-Hammer Circuit Breaker

Cutler-Hammer KDC2200 circuit breaker; 200 amp, 600 volt, two pole, 100 kAlC @ 480 volt AC, used electrically OK.
SKU: KDC2200
Contact us for pricing:

KDC2225 Cutler-Hammer Circuit Breaker

Cutler-Hammer KDC2225 circuit breaker; 225 amp, 600 volt, two pole, 100 kAlC @ 480 volt AC, used electrically OK.
SKU: KDC2225
Contact us for pricing:

KDC2250 Cutler-Hammer Circuit Breaker

Cutler-Hammer KDC2250 circuit breaker; 250 amp, 600 volt, two pole, 100 kAlC @ 480 volt AC, used electrically OK.
SKU: KDC2250
Contact us for pricing:

KDC2300 Cutler-Hammer Circuit Breaker

Cutler-Hammer KDC2300 circuit breaker; 300 amp, 600 volt, two pole, 100 kAlC @ 480 volt AC, used electrically OK.
SKU: KDC2300
Contact us for pricing:

KDC2350 Cutler-Hammer Circuit Breaker

Cutler-Hammer KDC2350 circuit breaker; 350 amp, 600 volt, two pole, 100 kAlC @ 480V AC, used electrically OK.
SKU: KDC2350
Contact us for pricing:

KDC2400 Cutler-Hammer Circuit Breaker

Cutler-Hammer KDC2400 circuit breaker; 400 amp, 600 volt, two pole, 100 kAlC @ 480 volt AC, used electrically OK.
SKU: KDC2400
Contact us for pricing:

KDC3100 Cutler-Hammer Circuit Breaker

Cutler-Hammer KDC3100 circuit breaker; 100 amp, 600 volt, three pole, 100 kAlC @ 480 volt AC, line & load side lugs. Used tested with report.
SKU: KDC3100
Contact us for pricing:

KDC3125 Cutler-Hammer Circuit Breaker

Cutler-Hammer KDC3125 circuit breaker; 125 amp, 600 volt, three pole, 100 kAlC @ 480 volt AC, line & load side lugs. Used tested with report.
SKU: KDC3125
Contact us for pricing:

KDC3150 Cutler-Hammer Circuit Breaker

Cutler-Hammer KDC3150 circuit breaker; 150 amp, 600 volt, three pole, 100 kAlC @ 480 volt AC, line & load side lugs. Used tested with report.
SKU: KDC3150
Contact us for pricing:

KDC3175 Cutler-Hammer Circuit Breaker

Cutler-Hammer KDC3175 circuit breaker; 175 amp, 600 volt, three pole, 100 kAlC @ 480 volt AC, line & load side lugs. Used tested with report.
SKU: KDC3175
Contact us for pricing:

KDC3200 Cutler-Hammer Circuit Breaker

Cutler-Hammer KDC3200 circuit breaker; 200 amp, 600 volt, three pole, 100 kAlC @ 480 volt AC, line & load side lugs. Used tested with report.
SKU: KDC3200
Contact us for pricing:

KDC3225 Cutler-Hammer Circuit Breaker

Cutler-Hammer KDC3225 circuit breaker; 225 amp, 600 volt, three pole, 100 kAlC @ 480 volt AC, line & load side lugs. Used tested with report.
SKU: KDC3225
Contact us for pricing:

KDC3250 Cutler-Hammer Circuit Breaker

Cutler-Hammer KDC3250 circuit breaker; 250 amp, 600 volt, three pole, 100 kAlC @ 480 volt AC, line & load side lugs. Used tested with report.
SKU: KDC3250
Contact us for pricing:

New, Used, and Tested Molded & Insulated Case Circuit Breakers

EMSCO has been specializing in used and refurbished molded & insulated case circuit breakers for over 72 years.


Why Choose EMSCO for Molded Case or Insulated Case Circuit Breakers?

Want to match and replace your existing breakers? End the hassle of retrofitting your electrical system. Our extensive inventory includes a variety of Molded Case Circuit Breakers (MCCBs) and Insulated Case Circuit Breakers that are designed to seamlessly match and replace your existing breakers by brand, amp rating, voltage, frame size, or model.

New and Refurbished Products in Stock

We understand that budgets and preferences differ, so we give you the option of selecting between new and refurbished MCCBs or Insulated Case Breakers, both of which are readily available in our inventory. Choose brand-new circuit breakers for maximum performance and longevity, or look into our refurbished options, which have been rigorously tested and reconditioned to meet industry standards.

Popular Brands and Common Configurations

Our shelves are stocked with breakers from the most trusted and popular brands in the industry, ensuring you have access to dependable products. You'll find common configurations, such as different frame sizes and voltage ratings, making it simple to find the right circuit protection for your application.

Avoiding Costly Operational Downtime

Downtime can be an expensive situation. Our circuit protection products are designed for high performance and durability. You can avoid costly operational downtime due to electrical failures by using our fully-tested Molded Case or Insulated Case breakers. Our products provide reliable power and superior equipment protection.

Electrical Testing Equipment Certifying Quality and Performance

When it comes to the dependability and safety of your electrical systems, we leave nothing to chance. Our breakers are rigorously tested using current testing equipment to ensure that they meet or exceed industry standards. This ensures that your electrical installations are safe and efficient.

  • Overcurrent Protection: We verify that your breakers provide accurate overcurrent protection, guaranteeing the safety of your electrical systems.
  • Trip Time: We measure the time it takes for breakers to respond to overcurrent conditions, ensuring it operates within the specified trip time.
  • Short-Circuit Withstand Capacity: Our testing evaluates the breaker’s ability to withstand short-circuit currents, preventing damage and maintaining safety.
  • Interrupting Capacity: We determine the MCCB's capability to interrupt fault currents, ensuring the utmost protection for your electrical system.

Molded Case Circuit Breaker Specifications

A sample table of ampere ratings, corresponding voltage ratings, and frame sizes for molded case circuit breakers is shown below. Please keep in mind that frame sizes and ratings can differ between manufacturers and models. For precise details on a specific MCCB, always refer to the manufacturer's specifications.

Frame Size

Ampere Rating

Voltage Rating

A

15A

120V, 240V

A

20A

120V, 240V

B

30A

120V, 240V, 480V

B50A120V, 240V, 480V
C60A240V, 480V
C100A240V, 480V
D150A240V, 480V, 600V
D200A240V, 480V, 600V
E250A240V, 480V, 600V
E300A240V, 480V, 600V
F400A240V, 480V, 600V
F600A240V, 480V, 600V
G800A240V, 480V, 600V
G1200A240V, 480V, 600V
H1600A240V, 480V, 600V

This table is a sample representation of frame sizes, ampere ratings, and voltage ratings for Molded Case Circuit Breakers, not an exhaustive list.

Molded case circuit breakers (MCCBs) and insulated case circuit breakers (ICCBs) are two distinct types of circuit protection devices used in electrical systems. Both serve the purpose of interrupting electrical currents in case of faults or overloads, but they differ in construction, application, and performance characteristics. Need Help Now? Call 800-328-1842.