Air Circuit Breakers

While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

15-GHK-500 ABB 15KV 1200A Air Circuit Breaker EO/DO

ABB 15-GHK-500 air circuit breaker; 1200 amp, 15 KV rated, three pole. Electrically operated, draw-out, close: 240 VAC, charge: 240 VAC, trip: 250 VDC, date: 08/89. Sold used as-is.
SKU: 15GHK500-EMSCO#19615

15GHK500 ABB 15KV 1200A EO/DO Air Circuit Breaker

ABB 15GHK500 Power circuit breaker; rated KV: 13.8, max KV: 15, impulse KV: 125, frequency: 60 rated, continuous current: 1200, K-Factor: 1.3 rated, Sym. short-circuit KA: 19.2, asymmetrical rating factor: 1.2. Electrically operated, draw-out, control voltage: charge: 240 VAC, close: 240 VAC, trip: 250 VDC, rated interr. time 3 cycles. Sold used as-is.
SKU: 15GHK500#19620

15-GHK-500 ABB 15KV 1200A EO/DO Air Circuit Breaker

ABB 15-GHK-500 air circuit breaker; 1200 amp, 15 KV rated, three pole. Electrically operated, draw-out, close: 240 VAC, charge: 240 VAC, trip: 250 VDC, date: 08/89. Sold used as-is.
SKU: 15GHK500-EMSCO#19616

15-GHK-500 ABB 15KV 1200A EO/DO Air Circuit Breaker

ABB 15-GHK-500 air circuit breaker; 1200 amp, 15 KV rated, three-pole. Electrically operated, draw-out, close: 240 VAC, charge: 240 VAC, trip: 250 VDC, date: 08/89. Sold used as-is.
SKU: 15GHK500-EMSCO#19617

15-GHK-500 ABB 15KV 1200A EO/DO Air Circuit Breaker

ABB 15-GHK-500 air circuit breaker; 1200 amp, 15 KV rated, three pole. Electrically operated, draw-out, close: 240 VAC, charge: 240 VAC, trip: 250 VDC, date: 08/89. Sold used as-is.
SKU: 15GHK500-EMSCO#19618

15GHK500 ABB/ITE 15KV 1200A EO/DO Air Circuit Breaker

ABB / ITE 15GHK500 Power Circuit Breaker; rated KV: 13.8, max KV: 15, impulse KV: 125, frequency: 60, rated continuous current: 1200, K-Factor: 1.3 rated Sym. short-circuit KA: 19.2, asymmetrical rating factor: 1.2. Electrically operated, draw-out, control voltage: charge: 240 VAC, close: 240 VAC, trip: 250 VDC, rated Interr. time 3 cycles. Sold used as-is.
SKU: 15GHK500 #19619

AM5-100 ABB 5KV CONVERSION EO/DO Air Circuit Breaker

ABB AM5-100 Vacuum circuit breaker; 5 HK, 1200 amp, 5 KV rated, three pole. Charge: 125 VDC, close: 125 VDC, electrically operated/draw-out, date: 09/99. Sold used as-is.
SKU: AM5-100 EMSCO#19593

AM5-100 ABB 5KV CONVERSION EO/DO Air Circuit Breaker

ABB AM5-100 vacuum circuit breaker; 5 HK, 1200 amp, 5 KV rated, three pole. Charge: 125 VDC, close: 125 VDC, electrically operated, draw-out, date: 09/99. Sold used as-is.
SKU: AM5-100 EMSCO#19594

Used ABB 15GHK500 Power Circuit Breaker - 13.8 KV Rated Voltage | EMSCO

For sale is a used ABB 15GHK500 Power Circuit Breaker, which is electrically operated and draw-out. The breaker has a rated voltage of 13.8 KV and a maximum voltage of 15 KV, with an impulse voltage of 125 KV. It operates at a frequency of 60 Hz and has a rated continuous current of 1200 A, with a K-Factor of 1.3. The breaker is rated for symmetrical short-circuit KA of 19.2 and an asymmetrical rating factor of 1.2. Its control voltage for charging is 240 VAC, for closing is 240 VAC, and for tripping is 250 VDC. The rated interruption time for the breaker is 3 cycles. Please note that this breaker is sold as-is.
SKU: 15GHK500 #19621

ABB 6 Terminal Simple Ground & Test Unit 3000A 5-15KV

ABB 6 Terminal Simple Ground & Test Unit; 3000 amp, 5-15 KV #23127, 3000 amps, 5-15 KV. Electrically operated, draw-out, serial# 1VAFACB48106004G09. Sold used electrically OK.
SKU: ABB-G&T-#23127

5HK ABB 5KV 1200A EO/DO Air Circuit Breaker

ABB 5HK air circuit breaker; 1200 amp, 5 KV rated, three pole, control: 48 Volt DC, electrically operated, draw-out. Sold used as-is.
SKU: 5HK - EMSCO # 19580

5HK ABB 5KV 1200A EO/DO Air Circuit Breaker

ABB 5HK air circuit breaker; 1200 amp, 5 KV rated, three pole, control: 48 volt DC, electronically operated, draw-out. Sold used as-is.
SKU: 5HK - EMSCO # 19579

K1600S ABB 1600A/1600A 600V Red MO/DO Air Breaker LI

ABB K1600S Power Circuit breaker; 1600 amp, 1600 amp CT. Red insulator, manually operated, draw-out, ABB type SS trip unit - solid state with LI functions. Sold Used As Is.
SKU: K1600S EMSCO #20990

K1600S ABB 1600A/1600A 600V Red MO/DO Air Breaker LI

ABB K1600S Power Circuit Breaker; 1600 Amp, 1600 Amp CT. Red Insulator, Manually operated/ draw-out, ABB Type SS Trip Unit - Solid State with LI Functions. Sold Used As Is.
SKU: K1600S EMSCO #20991

K-1600S ABB 1600A 600V Air Circuit Breaker EO/DO LSG

ABB K-1600S Power Circuit Breaker; 1600 amp frame, 1600 amp rated. Electrically operated, draw-out, 115 volt DC control, micro power-shield MPS-C-4G with LSG functions, red insulators. Used Electrically OK.
SKU: K1600S #20993

K-DON 1600S ABB 1600A 600V Fused Air Circuit Breaker EO/DO LSG

ABB K-Don 1600S Fused Power Circuit Breaker; 1600 amp frame, 600 volt, 1600 amp sensors. Gould A4BY2000, 2000 amp fuses power shield solid state trip, type SS4G with LSG functions. Ground fault intentionally defeated, electrically operated, draw-out, 115 volt DC, red insulators. Used Electrically OK.
SKU: K-DON1600S #20389

K-DON800M ABB 800A EO/DO Air Breaker LI

ABB K-DON-800M Fused Power Circuit Breaker; 800 amp, 600 volt. Electrically-operated, draw-out, trip: MP5-C-3 with L-I functions. Used Electrically OK.
SKU: K-DON800M #20954

K-DON800M ABB 800A EO/DO Air Breaker LI

ABB K-DON800M Fused Power Circuit Breaker; 800 amp, 600 volt. Electrically-operated, draw-out, trip: MP5-C-3 with L-I functions. Used electrically OK.
SKU: K-DON800M #20955

LK08 ABB 800A 600V EO/DO 120VAC LSI Air Circuit Breaker LSI

ABB ASEA LK08 Brown Boveri A.C. Low Voltage Power Circuit Breaker; 800 amp frame, 800 amp sensors, 600 volt AC. Electrically operated/ draw-out, charge: 120 VAC, close: 120 VAC, trip: 120 VAC, Micropower Shield Type MPS-5 with LSI functions. Used Electrically OK.
SKU: LK-08 # 20640

LK42 ABB/BBC 4200A 600V EO/DO Air Circuit Breaker LSG

ABB/BBC LK42 Brown Boveri A.C. Low Voltage Power Circuit Breaker; 4200 amp frame, 4200 amp sensors, 600 volt AC. Electrically operated, draw-out, charge: 240 VAC, close: 240 VAC, trip: 240 VDC, Micro-power Shield Type MPS-4G with LSG functions. Used electrically OK.
SKU: LK-42 # 21379

Used and Refurbished Air Circuit Breakers

Air Circuit Breakers (ACB’s) use air to extinguish electrical sparks. When a fault occurs, these circuit breakers disrupt the circuit by releasing a burst of compressed air, extinguishing the arc. This isolates the defective section of the system, preventing damage. High-pressure air cools the electrical arc.

Inventory Selection of Air Circuit Breakers to Match and Replace Yours

Our inventory features a wide range of air circuit breaker types to match and replace your existing electrical equipment seamlessly, ensuring compatibility and optimal performance for different applications. Whether you need a specific voltage rating, current capacity, or unique design, we have options that suit your needs.

New and Refurbished Air Circuit Breakers -- It's Your Choice

We offer customers the flexibility to choose between new and refurbished ACB’s. New circuit breakers ensure the latest technology and warranties, while refurbished breakers provide cost-effective solutions without compromising quality, backed by thorough inspections and testing.

Electrical testing equipment Certifies Quality and Performance

Our products undergo rigorous electrical testing using the newest test equipment to guarantee quality, safety, and optimal performance. Each air circuit breaker is thoroughly inspected, ensuring it meets industry standards and specifications.

Specifications Based on Your Power Requirements

To specify the right air circuit breaker, consider power requirements such as voltage, current rating, breaking capacity, and the type of application. In most cases, air circuit breakers are used where there’s high risk of fire or explosion. Air Breakers are typically used for low voltages up to 15KV.

Our expert team can guide you through selecting the most suitable breaker for your specific power needs.

What Type of Air Circuit Breaker Do You Need?

Air Breaker Type

How the Breaker Type Works

Applications

Plain Break Air Breaker

Utilizes a pair of contacts within a chamber filled with air to interrupt the electrical circuit. When the contacts separate, an arc forms and is extinguished by the surrounding air.

Commonly used in low-voltage applications like residential and commercial settings, protecting against overcurrents and short circuits.

Magnetic Blowout Air Breaker

Uses a magnetic field to drive the arc away from the contacts, ensuring quick interruption and extinguishing of the arc. The magnetic force redirects the arc into a chute, effectively extinguishing it.

Often found in industrial and heavy-duty settings due to their capability to handle high fault currents, making them ideal for heavy machinery and large-scale equipment protection.

Air Chute Breaker

Uses a series of parallel plates to create a chute for the arc. When the contacts open, the arc is diverted into the chute, where it is elongated, cooled, and extinguished before being directed toward the exhaust vent.

Commonly applied in medium-voltage power distribution systems, particularly in substations, to protect transformers and other critical power equipment from faults and overloads.

Air Blast Breaker

Relies on a high-pressure air blast to extinguish the arc. The compressed air directed towards the arc causes rapid cooling and interruption, ensuring efficient breaking of the circuit.

Primarily utilized in high-voltage applications like power stations and critical infrastructure such as data centers and hospitals, offering reliable protection against high fault currents and maintaining system integrity.