While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

AKR-10D-30S GE Air Breaker 600V 800A MO/DO LSIG

General Electric AKR-10D-30S low voltage power circuit breaker; 600 volt, 800 amp. Manually operated, draw-out, Micro versa trip plus LSIG functions. Used electrically OK.
SKU: AKR-10D-30S-#22928

AKR-10D-50H 1600A 600V MO/DO Air Breaker LSIG

General Electric AKR-10D-50H low voltage power circuit breaker; 1600 amp, 600 volt. Manually-operated, draw-out, RMS9 Trip: L-S-I-G. Used E-OK.
SKU: AKR-10D-50H #22214

AKR-10D-50H 1600A 600V MO/DO Air Breaker LSIG

General Electric AKR-10D-50H low voltage power circuit breaker; 1600 amp, 600 volt. Manually-operated, draw-out, RMS9 trip: L-S-I-G. Used E-OK.
SKU: AKR-10D-50H #22215

AKR-3D-75 GE Air Breaker 3200A Frame EO/DO MVT+ LSG

General Electric AKR-3D-75 low voltage power circuit breaker; 3200 amp frame, 600 volt AC class. Electrically operated, draw-out, Micro-Versa Trip Plus trip with LSG, part #TT32LSG, 3200 amp rating plug, C.T. closing trip: 120 VAC, operating range: 104-127 VAC. Used electrically OK.
SKU: AKR-3D-75 EMSCO#19613

AKR-4A-30 800A 600V EO/DO Air Breaker LI

General Electric AKR-4A-30 low voltage power circuit breaker; 800 amp, 600 volt. Electrically-operated, draw-out, type ECS trip: L-I. Used E-OK.
SKU: AKR-4A-30 #22248

AKR-4A-30 GE 800A 600V EO/DO Air Breaker LI

General Electric ARK-4A-30 low voltage power circuit breaker; AKR-4A-30 800 amp, 600 volt. Electrically-operated 240 volt AC, draw-out, type ECS trip unit with LI, 600 amp trip. Used E-OK.
SKU: AKR-4A-30 #21814

AKR-4A-30-1 GE Air Breaker 800A EO/DO LI

General Electric ARK-4A-30-1 low voltage power circuit breaker; 800 amp, 600 volt. Electrically-operated, 240 volt AC, draw-out, type ECS trip unit with LI functions, 600 amp trip. Used E-OK.
SKU: AKR-4A-30-1 #22217

AKR-4A-30-1 GE 800A FRAME 600V MO/DO Air Breaker LI

General Electric AKR-4A-30-1 low voltage power circuit breaker; 800 amp frame, 600 volt AC. Draw-out, 600 amp current sensor, GE type ECS trip unit, LI functions.
SKU: AKR-4A-30-1 #16701

AKR-4A-30-1 GE 800A FRAME MO/DO AIR BREAKER

General Electric AKR-4A-30-1 low voltage power circuit breaker; 800 amp frame, 600 volt AC. Manually Operated, draw-out, 600 amp current sensor, GE type ECS trip unit, LI functions.
SKU: AKR-4A-30-1 #16702

AKR-4A-30-1 GE Air Breaker 800A FRAME 600V MO/DO LI

General Electric AKR-4A-30-1 low voltage power circuit breaker; 800 amp frame, 600 volt AC. Manually operated, draw-out, 600 amp current sensor, GE type ECS trip unit, LI functions. Used electrically OK.
SKU: AKR-4A-30-1 #16703

AKR-4A-30-1 GE Air Breaker 800A FRAME 600V MO/DO LI

General Electric AKR-4A-30-1 low voltage power circuit breaker; 800 amp frame, 600 volt AC. Manually operated, draw-out, 600 amp current sensor, GE type ECS trip unit, LI functions. Used electrically OK.
SKU: AKR-4A-30-1 #19997

AKR-4A-30-1 GE Air Breaker 800A 600V MO/DO LI

General Electric AKR-4A-30-1 low voltage power circuit breaker; 800 amp, 600 volt. Manually operated, draw-out, ECS trip with LI functions. Used electrically OK.
SKU: AKR-4A-30-1-MO-DO-LI-#21951

AKR-4A-30-1 GE 600V 800A MO/DO Air Breaker LI

General Electric AKR-4A-30-1 low voltage power circuit breaker; 600, 800A. Manually operated, draw-out, ECS trip with LI functions. Used electrically OK.
SKU: AKR-4A-30-1 Emsco#22690

AKR-4A-30H-1 GE Air Breaker 800A Frame 600V MO/DO LI

General Electric AKR-4A-30H-1 low voltage power circuit breaker; 800 amp frame, 600 volt AC. Manually operated, draw-out, LI functions. Used electrically OK.
SKU: AKR-4A-30H-1 #19252

AKR-4A-30H-1 GE Air Breaker 800A Frame 600V MO/DO LI

General Electric AKR-4A-30H-1 low voltage power circuit breaker; 800 amp frame, 600 volt AC. Manually operated, draw-out, LI functions. Used electrically OK.
SKU: AKR-4A-30H-1 #19253

AKR-4A-30H-1 GE Air Breaker 800A Frame 600V MO/DO LI

General Electric AKR-4A-30H-1 low voltage power circuit breaker; 800 amp frame, 600 volt AC. Manually operated, draw-out, LI functions. Used electrically OK.
SKU: AKR-4A-30H-1 #19254

AKR-4A-30H-1 GE 800A Frame 600V MO/DO Air Breaker LI

General Electric AKR-4A-30H-1 low voltage power circuit breaker; 800 amp frame, 600 volt AC. Manually operated, draw-out, LI functions. Used electrically OK.
SKU: AKR-4A-30H-1 #19255

AKR-4A-30H-1 GE Air Breaker 800A 600V MO/DO LI

General Electric AKR-4A-30H-1 low voltage power circuit breaker; 800 amp, 600 volt. Manually operated, draw-out, ECS trip, LI functions. Used electrically OK.
SKU: AKR-4A-30H-1-MO-DO-LI-#21950

AKR-4A-50 GE 1600A Frame 1200A Rated 600V MO/DO Air Breaker LI

General Electric AKR-7D-50 low voltage power circuit breaker; 1600 amp frame, 600 volt. Manually operated, draw-out, type ECS trip with LI functions with 1200 amp trip. Used electrically OK.
SKU: AKR-7D-50 EMSCO #22184

AKR-4A-50 GE 1600A Frame 1200A Rated 600V MO/DO Air Breaker LI

General Electric AKR-7D-50 low voltage power circuit breaker; 1600 amp frame, 600 volt. Manually operated, draw-out type ECS trip with LI functions with 1200 amp trip. Used electrically OK.
SKU: AKR-7D-50 EMSCO #22185

Used and Refurbished Air Circuit Breakers

Air Circuit Breakers (ACB’s) use air to extinguish electrical sparks. When a fault occurs, these circuit breakers disrupt the circuit by releasing a burst of compressed air, extinguishing the arc. This isolates the defective section of the system, preventing damage. High-pressure air cools the electrical arc.

Inventory Selection of Air Circuit Breakers to Match and Replace Yours

Our inventory features a wide range of air circuit breaker types to match and replace your existing electrical equipment seamlessly, ensuring compatibility and optimal performance for different applications. Whether you need a specific voltage rating, current capacity, or unique design, we have options that suit your needs.

New and Refurbished Air Circuit Breakers -- It's Your Choice

We offer customers the flexibility to choose between new and refurbished ACB’s. New circuit breakers ensure the latest technology and warranties, while refurbished breakers provide cost-effective solutions without compromising quality, backed by thorough inspections and testing.

Electrical testing equipment Certifies Quality and Performance

Our products undergo rigorous electrical testing using the newest test equipment to guarantee quality, safety, and optimal performance. Each air circuit breaker is thoroughly inspected, ensuring it meets industry standards and specifications.

Specifications Based on Your Power Requirements

To specify the right air circuit breaker, consider power requirements such as voltage, current rating, breaking capacity, and the type of application. In most cases, air circuit breakers are used where there’s high risk of fire or explosion. Air Breakers are typically used for low voltages up to 15KV.

Our expert team can guide you through selecting the most suitable breaker for your specific power needs.

What Type of Air Circuit Breaker Do You Need?

Air Breaker Type

How the Breaker Type Works

Applications

Plain Break Air Breaker

Utilizes a pair of contacts within a chamber filled with air to interrupt the electrical circuit. When the contacts separate, an arc forms and is extinguished by the surrounding air.

Commonly used in low-voltage applications like residential and commercial settings, protecting against overcurrents and short circuits.

Magnetic Blowout Air Breaker

Uses a magnetic field to drive the arc away from the contacts, ensuring quick interruption and extinguishing of the arc. The magnetic force redirects the arc into a chute, effectively extinguishing it.

Often found in industrial and heavy-duty settings due to their capability to handle high fault currents, making them ideal for heavy machinery and large-scale equipment protection.

Air Chute Breaker

Uses a series of parallel plates to create a chute for the arc. When the contacts open, the arc is diverted into the chute, where it is elongated, cooled, and extinguished before being directed toward the exhaust vent.

Commonly applied in medium-voltage power distribution systems, particularly in substations, to protect transformers and other critical power equipment from faults and overloads.

Air Blast Breaker

Relies on a high-pressure air blast to extinguish the arc. The compressed air directed towards the arc causes rapid cooling and interruption, ensuring efficient breaking of the circuit.

Primarily utilized in high-voltage applications like power stations and critical infrastructure such as data centers and hospitals, offering reliable protection against high fault currents and maintaining system integrity.