Air Circuit Breakers

While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

5-GMI-250-2000-58 Siemens 2000A 5KV AC High Voltage Air Circuit Breaker EO/DO

Siemens 5-GMI-250-2000-58 AC high voltage circuit breaker; rated max. volts: 4.76 kV, volt range factor: 1.24K Bil. kV, 60 rated short circuit kA: 29, close latch kA 58, interrupting time: 5 cycles. Electrically operated, motor: 100-140 VDC, 2.5 amps. nominal close: 100-140 VDC, 3.8 amps. nominal trip: 70-140 VDC, 3.8 amps. nominal draw-out, used electrically OK.
SKU: 5-GMI-250-2000-58 #20693

5-GMI-350-3000-78 Siemens 3000A 5KV AC High Voltage Air Circuit Breaker EO/DO New Surplus

Siemens Part # 5-GMI-350-3000-78 GMI AC high voltage circuit breaker; 5 KV max, 3000 amp. Electrically operated, draw-out, 100-140 VDC control voltage, MFG date 02/2009. New Surplus
SKU: 5-GMI-350-3000-78 EMSCO #20935

AM5-100 ABB 5KV CONVERSION EO/DO Air Circuit Breaker

ABB AM5-100 Vacuum circuit breaker; 5 HK, 1200 amp, 5 KV rated, three pole. Charge: 125 VDC, close: 125 VDC, electrically operated/draw-out, date: 09/99. Sold used as-is.
SKU: AM5-100 EMSCO#19593

AM5-100 ABB 5KV CONVERSION EO/DO Air Circuit Breaker

ABB AM5-100 vacuum circuit breaker; 5 HK, 1200 amp, 5 KV rated, three pole. Charge: 125 VDC, close: 125 VDC, electrically operated, draw-out, date: 09/99. Sold used as-is.
SKU: AM5-100 EMSCO#19594

V5D3153Y000 A SQ D VR 1200 AMP 5KV EO/DO Air Circuit Breaker

Square D #V5D3153Y000 A medium voltage circuit breaker; type VR, 12000 amp, 4.76 KV (4760 volt) rated. Electrically operated, draw-out, closing coil: 104-127 VAC, 6.8 amp, tripping coil: 70-140 VDC, 0.7 amp in outdoor house, used electrically OK.
SKU: V5D3153Y000 #22155

VB 4.16-250-1 G.E. 5KV 1200A EO/DO Air Circuit Breaker

General Electric VB 4.16-250-1 Power VAC circuit breaker; 1200 amp, 5 KV rated, electrically operated, draw-out. Close coil: 230 VAC, trip coil: 325 VDC, Mech type: ML-17. Used as is.
SKU: VB 4.16-250-1-EMSCO #19568

VB1 4.16-250-2 G.E. 5KV 1200A EO/DO Air Circuit Breaker

General Electric VB1 4.16-250-2 Power VAC circuit breaker; 1200 amp, 5 KV rated, electrically operated, draw-out. Close coil: 125 VDC, trip coil: 125 volt DC, mech type: ML-18. Used as is.
SKU: VB1 4.16-250-2-EMSCO #19583

VB1 4.16-250-2 G.E. 5KV 1200A EO/DO Air Circuit Breaker

General Electric VB1 4.16-250-2 Power VAC circuit breaker; 1200 amp, 5 KV rated, electrically operated, draw-out. Close coil: 125 VDC, trip coil: 125 VDC, mech type: ML-18. Used as is.
SKU: VB1 4.16-250-2-EMSCO #19584

VB1 4.16-250-2 G.E. 5KV 1200A EO/DO Air Circuit Breaker

General Electric VB1 4.16-250-2 Power VAC circuit breaker; 1200 amp, 5 KV rated, electrically operated, draw-out. Close coil: 125 VDC, trip coil: 125 VDC, mech type: ML-18. Used as is.
SKU: VB1 4.16-250-2-EMSCO #19585

VB1 4.16-250-2 G.E. 5KV 1200A EO/DO Air Circuit Breaker

General Electric VB1 4.16-250-2; Power VAC circuit breaker; 1200 amp, 5 KV rated, electrically operated, draw-out. Close coil: 125 VDC, trip coil: 125 VDC, mech type: ML-18 *. Note: partially broken orange phenolic piece *
SKU: VB1 4.16-250-2-EMSCO #19586

VB1 4.16-250-2 G.E. 5KV 1200A EO/DO Air Circuit Breaker

General Electric VB1 4.16-250-2 Power VAC circuit breaker; 1200 amp, 5 KV rated, electric operated, draw-out. Close coil: 48 VDC, trip coil: 48 volt DC, mech type: ML-18, date: 12/92. Used as is.
SKU: VB1 4.16-250-2-EMSCO #19589

VB1 4.16-250-2 G.E. 5KV 1200A EO/DO Air Circuit Breaker

General Electric VB1 4.16-250-2 Power VAC circuit breaker; 1200 amp, 5 KV rated, electrically operated, draw-out. Close coil: 48 VDC, trip coil: 48 volt DC, mech type: ML-18, date: 12/92. Used as is.
SKU: VB1 4.16-250-2-EMSCO #19591

VB1 4.16-250-2 G.E. 5KV 1200A EO/DO Air Circuit Breaker

General Electric VB1 4.16-250-2 Power VAC circuit breaker; 1200 amp, 5 KV rated, electrically operated, draw-out. Close coil: 48 VDC, trip coil: 48 VDC, mech type: ML-18, date: 12/92. Used as is.
SKU: VB1 4.16-250-2-EMSCO #19592

VB-13.8-750-3 General Electric 15KV 1200A EO/DO Air Circuit Breaker

General Electric VB-13.8-750-3 power VAC circuit breaker; 1200 amp, 15 KV, three pole, control: 125 volt DC, electrically operated, draw-out. Sold used as is.
SKU: VB-13.8-750-3 - EMSCO # 19554

VB1-4.16-250-2 GE 5KV 1200A EO/DO Air Circuit Breaker

General Electric VB1-4.16-250-2 power VAC circuit breaker; 1200 amp, 5 KV, three pole, control: 125 volt DC, electrically operated, draw-out. Sold used as-is.
SKU: VB1-4.16-250-2 - EMSCO # 19601

50DH250E WESTINGHOUSE 5KV 1200A EO/DO Air Circuit Breaker

Westinghouse 50DH250E air circuit breaker; 1200 amp, 5 KV rated electrically operated, draw-out, closing voltage: 125 volt DC, date: 02/73, used as is.
SKU: 50DH250E -EMSCO #19941

50DH250E WESTINGHOUSE 5KV 1200A EO/DO Air Circuit Breaker

Westinghouse 50DH250E air circuit breaker; 1200 amp, 5 KV rated, electrically operated, draw-out. Closing voltage: 125 volt DC (3), three bent stab fingers, used as is.
SKU: 50DH250E-EMSCO #19940

50DHP350 Westinghouse Air Breaker 3000A 5KV EO/DO

Westinghouse 50DHP350 Air Breaker; 3000 amp, 5 KV, electrically operated, draw-out, motor volts: 230 AC, closing volts: 190-250 AC. Used sold electrically OK.
SKU: 50-DHP-350-EO-DO-#22756

50DHP350 Westinghouse Air Breaker 3000A 5KV EO/DO

Westinghouse 50DHP350 Air Breaker; 3000 amp, 5 KV, electrically operated, draw-out, closing volts: 190-250 AC. Used sold electrically OK.
SKU: 50-DHP-350-EO-DO-#21955

50DH250E WESTINGHOUSE 5KV 1200A EO/DO Air Breaker

Westinghouse 50DH250E air circuit breaker; 1200 amp, 5 KV rated. Electrically operated, draw-out, closing voltage: 125 volt DC, used as is.
SKU: 50DH250E-EMSCO #19937

Used and Refurbished Air Circuit Breakers

Air Circuit Breakers (ACB’s) use air to extinguish electrical sparks. When a fault occurs, these circuit breakers disrupt the circuit by releasing a burst of compressed air, extinguishing the arc. This isolates the defective section of the system, preventing damage. High-pressure air cools the electrical arc.

Inventory Selection of Air Circuit Breakers to Match and Replace Yours

Our inventory features a wide range of air circuit breaker types to match and replace your existing electrical equipment seamlessly, ensuring compatibility and optimal performance for different applications. Whether you need a specific voltage rating, current capacity, or unique design, we have options that suit your needs.

New and Refurbished Air Circuit Breakers -- It's Your Choice

We offer customers the flexibility to choose between new and refurbished ACB’s. New circuit breakers ensure the latest technology and warranties, while refurbished breakers provide cost-effective solutions without compromising quality, backed by thorough inspections and testing.

Electrical testing equipment Certifies Quality and Performance

Our products undergo rigorous electrical testing using the newest test equipment to guarantee quality, safety, and optimal performance. Each air circuit breaker is thoroughly inspected, ensuring it meets industry standards and specifications.

Specifications Based on Your Power Requirements

To specify the right air circuit breaker, consider power requirements such as voltage, current rating, breaking capacity, and the type of application. In most cases, air circuit breakers are used where there’s high risk of fire or explosion. Air Breakers are typically used for low voltages up to 15KV.

Our expert team can guide you through selecting the most suitable breaker for your specific power needs.

What Type of Air Circuit Breaker Do You Need?

Air Breaker Type

How the Breaker Type Works

Applications

Plain Break Air Breaker

Utilizes a pair of contacts within a chamber filled with air to interrupt the electrical circuit. When the contacts separate, an arc forms and is extinguished by the surrounding air.

Commonly used in low-voltage applications like residential and commercial settings, protecting against overcurrents and short circuits.

Magnetic Blowout Air Breaker

Uses a magnetic field to drive the arc away from the contacts, ensuring quick interruption and extinguishing of the arc. The magnetic force redirects the arc into a chute, effectively extinguishing it.

Often found in industrial and heavy-duty settings due to their capability to handle high fault currents, making them ideal for heavy machinery and large-scale equipment protection.

Air Chute Breaker

Uses a series of parallel plates to create a chute for the arc. When the contacts open, the arc is diverted into the chute, where it is elongated, cooled, and extinguished before being directed toward the exhaust vent.

Commonly applied in medium-voltage power distribution systems, particularly in substations, to protect transformers and other critical power equipment from faults and overloads.

Air Blast Breaker

Relies on a high-pressure air blast to extinguish the arc. The compressed air directed towards the arc causes rapid cooling and interruption, ensuring efficient breaking of the circuit.

Primarily utilized in high-voltage applications like power stations and critical infrastructure such as data centers and hospitals, offering reliable protection against high fault currents and maintaining system integrity.