While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

5-GMI-250-2000-58 Siemens 2000A 5KV AC High Voltage Air Circuit Breaker EO/DO

Siemens 5-GMI-250-2000-58 AC high voltage circuit breaker; rated max. volts: 4.76 kV, volt range factor: 1.24K Bil. kV, 60 rated short circuit kA: 29, close latch kA 58, interrupting time: 5 cycles. Electrically operated, motor: 100-140 VDC, 2.5 amps. nominal close: 100-140 VDC, 3.8 amps. nominal trip: 70-140 VDC, 3.8 amps. nominal draw-out, used electrically OK.
SKU: 5-GMI-250-2000-58 #20693

5-GMI-350-3000-78 Siemens 3000A 5KV AC High Voltage Air Circuit Breaker EO/DO New Surplus

Siemens Part # 5-GMI-350-3000-78 GMI AC high voltage circuit breaker; 5 KV max, 3000 amp. Electrically operated, draw-out, 100-140 VDC control voltage, MFG date 02/2009. New Surplus
SKU: 5-GMI-350-3000-78 EMSCO #20935

VV-1500 Siemens AC High-Voltage Air Circuit Breaker 1200A 38KV EO/DO

Siemens Type VV-1500 AC High-Voltage circuit breaker; rated max. volts: 38,000, rated amps: 1200, cycle: 60, voltage range K factor: 1.65, interrupting time cycle: 3, impulse level kV: 150, for use in IV-34 type switch gear. Electrically operated, draw out, with stored energy operator: type 515-4V, motor: 125 VDC, close voltage: 90-130 DC, trip voltage: 70-14 DC, close current (Nom.) 4.0 amps, trip current (Nom.) 4.0 amps, motor current (Nom.) 7.0 amps. Used electrically Okay.
SKU: VV-1500 #20239

VV-1500 Siemens AC High-Voltage Air Circuit Breaker 1200A 38KV EO/DO

Siemens Type VV-1500 AC High-Voltage circuit breaker; rated max. volts: 38,000, rated amps: 1200, cycle: 60, voltage range K factor: 1.65, interrupting time cycle: 3, impulse level kV: 150, for use in IV-34 type switchgear. Electrically operated, draw-out, with stored energy operator: type 515-4V motor: 125 VDC, close voltage: 90-130 DC, trip voltage: 70-14 DC, close current (Nom.) 4.0 amps, trip current (Nom.) 4.0 amps, motor current (Nom.) 7.0 amps. Used electrically Okay.
SKU: VV-1500 #20240

VV-1500 Siemens AC High-Voltage Air Circuit Breaker 1200A 38KV EO/DO

Siemens Type VV-1500 AC High-Voltage circuit breaker; rated max. volts: 38,000, rated amps: 1200, cycle: 60, voltage range K factor: 1.65, interrupting time cycle: 3, impulse level kV: 150, for use in IV-34 type switchgear. Electrically operated, draw-out, with stored energy operator: type 515-4V motor: 125 VDC, close voltage: 90-130 DC, trip voltage: 70-14 DC, close current (Nom.) 4.0 amps, trip current (Nom.) 4.0, amps motor current (Nom.) 7.0 amps. Used electrically Okay.
SKU: VV-1500 #20241

VV-1500 Siemens AC High-Voltage Air Circuit Breaker 1200A 38KV EO/DO

Siemens Type VV-1500 AC High-Voltage circuit breaker; rated max. volts: 38,000, rated amps: 1200, cycle: 60, voltage range K factor: 1.65, interrupting time cycle: 3, impulse level kV: 150, for use in IV-34 type switchgear. Electrically operated, draw-out, with stored energy operator: type 515-4V. Motor: 125 VDC, close voltage: 90-130 DC, trip voltage: 70-14 DC, close current (Nom.) 4.0 amps, trip current (Nom.) 4.0 amps, motor current (Nom.) 7.0 amps. Used electrically Okay.
SKU: VV-1500 #20242

RLX-1600 Siemens 1600A 600V Air Breaker MO/DO LS

Siemens RLX-1600 Type RL Low Voltage Air Circuit Breaker; 1600 amp frame, 600 volt. Static trip III RMS-TS-TZ-C with LS functions, Manually operated, draw-out, 1600:0.5 CT's. Used Electrically OK.
SKU: RLX-1600 EMSCO# 202567

RLX-1600 Siemens 1600A 600V Air Breaker MO/DO LS

Siemens RLX-1600 Low Voltage Air Circuit Breaker; 800 amp frame, 600 volt. Static trip III with LS functions. Manually operated, draw-out, 1600/0.5 CT's. Used Electrically OK.
SKU: RLX-1600 EMSCO# 21231

RLX-1600 Siemens 1600A 600V Air Breaker MO/DO LS

Siemens RLX-1600 Low Voltage Air Circuit Breaker; type RL, 800 amp frame, 600 volt. Static trip III with LS functions. Manually operated, draw-out, 1600/0.5 CT's. Used Electrically OK.
SKU: RLX-1600 EMSCO# 21232

RLX-1600 Siemens 1600A 600V Air Breaker MO/DO LS

Siemens RLX-1600 Type RL Low Voltage Air Circuit Breaker; 1600 amp frame, 600 volt. Static trip III RMS-TS-TZ-C with LS functions. Manually operated, draw-out, 1600:0.5 CT's. Used electrically OK.
SKU: RLX-1600 EMSCO# 202566

RLX-1600 Siemens 1600A 600V Air Breaker MO/DO LS

Siemens RLX-1600 Low Voltage Air Circuit Breaker; type RL, 1600 amp frame, 600 volt. Static trip III RMS-TS-TZ-C with LS functions. Manually operated, draw-out, 1600:0.5 CT's. Used electrically OK.
SKU: RLX-1600 EMSCO# 202564

RLX-1600 Siemens 1600A 600V Air Breaker MO/DO LS

Siemens RLX-1600 Type RL Low Voltage Air Circuit Breaker; 1600 amp frame, 600 volt. Static trip III RMS-TS-TZ-C with LS functions. Manually operated, draw-out, 1600:0.5 CT's. Used Electrically OK.
SKU: RLX-1600 EMSCO# 202565

RLF-800 Siemens 800A Frame 600A Rated 600V Fused Air Breaker EO/DO LSIG

Siemens Low Voltage Power Circuit Breaker Type RLF-800; 800 amp frame, 600 volt. Digitrip RMS/R 800 #RH86CLSIG with LSIG functions, 600 amp rating plug #PR6A08A060. Electrically operated, draw-out, Motor Volts: 120 VAC, Close Volts: 120 VAC, Trip Volts: 120 VAC, Type Q-11 Auxiliary Switch Potential Transformer Module #PRTAPTM, 400/800:5 amp CT's, 600 amp fuses. Used Electrically OK.
SKU: RLF800 #20571

RL-4000 Siemens 4000A 600V Air Breaker EO/DO LSG

Siemens RL-4000 Low Voltage Power Circuit Breaker; 4000 amp frame, 600 volt, 4000 amp current sensors, 2000 amp Grd. sensors (when used). Static Trip III - RMS-TSG-TZ-C with LSG functions. Electrically operated, draw-out, motor volts: 120 VAC, close volts: 120 VAC, trip volts: 120 VAC, type Q-11 auxiliary switch, 4000/.5 CT's. Used Electrically OK.
SKU: RL4000 EMSCO# 20529

RL-4000 Siemens 4000A 600V Air Breaker EO/DO LSG

Siemens RL-4000 Low Voltage Power Circuit Breaker; 4000 amp frame, 4000 amp current sensors, 2000 amp Grd. sensors (when used). Static Trip III - RMS-TSG-TZ-C with LSG functions. Electrically operated, draw-out, motor volts: 120 VAC, close volts: 120 VAC, trip volts: 120 VAC, type Q-11 auxiliary switch, 4000/.5 CT's. Used Electrically OK.
SKU: RL4000 EMSCO# 20530

RLF800 Siemens 800A Frame/800A Rating Plug Fused Air Breaker EO/DO LSIG

Siemens RLF800 AC fused low voltage power circuit breaker; 800 amp frame, 800 amp rating plug (#PR6A08A080). Electrically operated, draw-out, motor volts: 120 VAC, close volts: 120 VAC, trip volts: 120 VAC. Digitrip RMS/R 800, trip unit #RH86CLSIG (LSIG functions), potential transformer module #PRTAPTM, type Q-11 auxiliary switch 800:5 amp C.T.'s. Used electrically OK.
SKU: RLF800 EMSCO #21290

RL-1600 Siemens Air Breaker 1600A MO/DO LSIG 800A Sensor New Surplus

Siemens RL-1600 Air Breaker; 1600 amp, 600 volt. Manually operated, draw-out, Siemens Static III Trip with LSIG functions, 800 amp sensor rating. New surplus take-out.
SKU: RL-1600-MO-DO-LSIG-#21957

RL-3200 Siemens Air Breaker 3200A 600V MO/DO LSG

Siemens RL-3200 Air Breaker; 3200 amp, 600 volt. Manually operated, draw-out, Siemens Static Trip III with LSG functions. Used electrically OK.
SKU: RL-3200-MO-DO-LSG-#22349

RL-3200 Siemens 3200A 600V Air Breaker MO/DO LSIG

Siemens RL-3200 Low Voltage Power Circuit Breaker; 3200 amp frame, 600 volt. Static Trip III with LSIG functions. Manually operated, draw-out, 3200 amp CT with cell. Used electrically OK.
SKU: RL3200 EMSCO# 21390

RL-4000 Siemens 4000A 600V Air Breaker EO/DO LSG

Siemens Type RL Low Voltage Power Circuit Breaker RL-4000; 4000 amp Frame, 600 volt, 4000 amp current sensors. 2000 amp Grd. Sensors (when used), Static Trip III - RMS-TSG-TZ-C LSG functions. Electrically operated, draw-out, Motor Volts: 120 VAC, Close Volts: 120 VAC, Trip Volts: 120 VAC, Type Q-11 Auxiliary Switch 4000/.5 CT's. Used Electrically OK.
SKU: RL4000 EMSCO# 21351

Used and Refurbished Air Circuit Breakers

Air Circuit Breakers (ACB’s) use air to extinguish electrical sparks. When a fault occurs, these circuit breakers disrupt the circuit by releasing a burst of compressed air, extinguishing the arc. This isolates the defective section of the system, preventing damage. High-pressure air cools the electrical arc.

Inventory Selection of Air Circuit Breakers to Match and Replace Yours

Our inventory features a wide range of air circuit breaker types to match and replace your existing electrical equipment seamlessly, ensuring compatibility and optimal performance for different applications. Whether you need a specific voltage rating, current capacity, or unique design, we have options that suit your needs.

New and Refurbished Air Circuit Breakers -- It's Your Choice

We offer customers the flexibility to choose between new and refurbished ACB’s. New circuit breakers ensure the latest technology and warranties, while refurbished breakers provide cost-effective solutions without compromising quality, backed by thorough inspections and testing.

Electrical testing equipment Certifies Quality and Performance

Our products undergo rigorous electrical testing using the newest test equipment to guarantee quality, safety, and optimal performance. Each air circuit breaker is thoroughly inspected, ensuring it meets industry standards and specifications.

Specifications Based on Your Power Requirements

To specify the right air circuit breaker, consider power requirements such as voltage, current rating, breaking capacity, and the type of application. In most cases, air circuit breakers are used where there’s high risk of fire or explosion. Air Breakers are typically used for low voltages up to 15KV.

Our expert team can guide you through selecting the most suitable breaker for your specific power needs.

What Type of Air Circuit Breaker Do You Need?

Air Breaker Type

How the Breaker Type Works

Applications

Plain Break Air Breaker

Utilizes a pair of contacts within a chamber filled with air to interrupt the electrical circuit. When the contacts separate, an arc forms and is extinguished by the surrounding air.

Commonly used in low-voltage applications like residential and commercial settings, protecting against overcurrents and short circuits.

Magnetic Blowout Air Breaker

Uses a magnetic field to drive the arc away from the contacts, ensuring quick interruption and extinguishing of the arc. The magnetic force redirects the arc into a chute, effectively extinguishing it.

Often found in industrial and heavy-duty settings due to their capability to handle high fault currents, making them ideal for heavy machinery and large-scale equipment protection.

Air Chute Breaker

Uses a series of parallel plates to create a chute for the arc. When the contacts open, the arc is diverted into the chute, where it is elongated, cooled, and extinguished before being directed toward the exhaust vent.

Commonly applied in medium-voltage power distribution systems, particularly in substations, to protect transformers and other critical power equipment from faults and overloads.

Air Blast Breaker

Relies on a high-pressure air blast to extinguish the arc. The compressed air directed towards the arc causes rapid cooling and interruption, ensuring efficient breaking of the circuit.

Primarily utilized in high-voltage applications like power stations and critical infrastructure such as data centers and hospitals, offering reliable protection against high fault currents and maintaining system integrity.