Air Circuit Breakers

While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

AK-2A-75 GE 3000A Frame/3000 Amp Trip Unit 600V EO/DO Air Breaker LSI

General Electric AK-2A-75 low voltage power circuit breaker; 3000 amp frame, 3000 amp trip, 600 volt. SB-12 auxiliary switch, electrically operated, closing voltage, 230 volt, draw-out, versa-trip with LSI. Sold used electrically OK.
SKU: AK-2A-75 EMSCO #21835

AK-2A-75 GE 3000A Frame/3000Amp Trip Unit 600V EO/DO Air Breaker LS

General Electric AK-2A-75 low voltage power circuit breaker; 3000 amp frame, 3000 amp trip, 600 volt. SB-12 auxiliary switch, electrically operated, closing voltage: 230 volt, draw-out, RMS-9 with LS. Sold used electrically OK.
SKU: AK-3A-75 EMSCO #21898

AK-2A-75-1 GE 3000A Frame/3000A Trip Unit 600V EO/DO Air Breaker

General Electric AK-2A-75-1 low voltage power circuit breaker; 3000 amp frame, 3000 amp trip, 600 volt. SB-12 auxiliary switch, electrically operated, closing voltage 230 volt, draw-out, RMS-9 with LSI functions. Sold used electrically OK.
SKU: AK-2A-75-1 EMSCO #21897

AK-3A-100 GE Air Breaker 600V 4000A MO/DO LS

General Electric AK-3A-100 low voltage A.C. power circuit breaker; 600 volt, 4000 amp. Manually operated, draw-out, power sensor trip with LS functions. Used electrically OK.
SKU: AK-3A-100-MO-DO-#22927

AK3A-25 GE 600A Frame 600A Rated 600V MO/DO Air Breaker LS

General Electric AK3A-25 low voltage power circuit breaker; 600 amp frame, 600 amp sensors, 600 volt. Manually operated, draw-out, 125 volt DC shunt trip, power sensor trip unit type PS-1A with LS functions. Sold used electrically OK.
SKU: AK-3A-25 EMSCO #20846

AK3A-25 GE 600A Frame 600A Rated 600V MO/DO Air Breaker LS

General Electric AK3A-25 low voltage power circuit breaker; 600 amp frame, 600 amp sensors, 600 volt. Manually operated, draw-out, 125 volt DC shunt trip power sensor trip unit type PS-1A with LS functions.
SKU: AK-3A-25 EMSCO #20848

AK3A-25 GE 600A Frame 600A Rated 600V MO/DO Air Breaker LS

General Electric AK3A-25 low voltage power circuit breaker; 600 amp frame, 600 amp sensors, 600 volt. Manually operated, draw-out, 125 volt DC shunt trip, power sensor trip unit type PS-1A with LS functions. Sold used electrically OK.
SKU: AK-3A-25 EMSCO #20849

AK-3A-25 GE 600A Frame 600A Rated 600V MO/DO Air Breaker LS

General Electric AK-3A-25 low voltage power circuit breaker; 600 amp frame, 600 amp sensors, 600 volt. Manually operated, draw-out, power sensor trip unit type PS-1A with LS functions. Sold used electrically OK.
SKU: AK-3A-25 EMSCO #21065

AK-3A-25 GE 600A Frame 600A Rated 600V MO/DO Air Breaker LS

General Electric AK-3A-25 low voltage power circuit breaker; 600 amp frame, 600 amp sensors, 600 volt. Manually operated, draw-out, power sensor trip unit type PS-1A with LS functions. Sold used electrically OK.
SKU: AK-3A-25 EMSCO #21066

AK-3A-25 GE 600A Frame 600A Rated 600V MO/DO Air Breaker LS

General Electric AK-3A-25 low voltage power circuit breaker; 600 amp frame, 600 amp sensors, 600 volt. Manually operated, draw-out, power sensor trip unit type PS-1A with LS functions. Sold used electrically OK.
SKU: AK-3A-25 EMSCO #21067

AK-3A-25 GE 600A Frame 70A Rated 600V MO/DO Air Breaker LS

General Electric AK-3A-25 low voltage power circuit breaker; 600 amp frame, 70 amp sensors, 600 volt. Manually operated, draw-out, power sensor trip unit type PS-1A with LS functions. Sold used electrically OK.
SKU: AK-3A-25 EMSCO #21062

AK-3A-25 GE 600A Frame 70A Rated 600V MO/DO Air Breaker LS

General Electric AK-3A-25 low voltage power circuit breaker; 600 amp frame, 70 amp sensors, 600 volt. Manually operated, draw-out, power sensor trip unit type PS-1A with LS functions. Sold used electrically OK.
SKU: AK-3A-25 EMSCO #21064

AK-3A-50 GE 1600A Frame 1600A Rated 600V EO/DO Air Breaker LS

General Electric AK-3A-50 low voltage A.C. power circuit breaker; 1600 amp frame, 1600 amp sensors 600 volt. Electrically operated, closing voltage 120 VDC, operating voltage 90-150, draw-out power sensor trip unit type PS-1 with LS. Sold used electrically OK.
SKU: AK-3A-50 EMSCO #21460

AK-3A-75 GE Air Breaker 3000A 600V EO/DO LS

General Electric AK-3A-75 low voltage power circuit breaker; 3000 amp, 600 volt. Electrically operated, draw-out, power sensor 3000 amp trip, LS functions, 230 closing volts. Used electrically OK.
SKU: AK-3A-75-EO-DO-LS-#22381

AKR-4A-50 GE Air Breaker 1600A 600V EO/DO LS

General Electric AKR-4A-50 low voltage power circuit breaker; 1600 amp, 600 volt. Electrically operated, draw-out, 120 VAC, ECS trip with LS functions. Used electrically OK.
SKU: AKR-4A-50-EO-DO-LS-#21926

AKR-4A-50 GE Air Breaker 1600A 600V EO/DO LS

General Electric AKR-4A-50 low voltage power circuit breaker; 1600 amp, 600 volt. Electrically operated, draw-out, 120 VAC ECS trip with LS functions. Used electrically OK.
SKU: AKR-4A-50-EO-DO-LS-#21927

AKR-4A-50 GE Air Breaker 1600A 600V EO/DO LS

General Electric AKR-4A-50 low voltage power circuit breaker; 1600 amp, 600 volt. Electrically operated, draw-out, 120 VAC ECS trip with LS functions. Used electrically OK.
SKU: AKR-4A-50-EO-DO-LS-#21928

AKR-4C-75 GE Air Breaker 3200A 600V EO/DO LS

General Electric AKR-4C-75 low voltage power circuit breaker; 3200 amp, 600 volt, 3200 amp sensor. Electrically operated, draw-out, ECS trip: LS functions, 120 volt closing voltage. Used E-OK.
SKU: AKR-4C-75 #22166

AKR-6D-75 GE 3200A Frame 3200A Rated 600V EO/DO Air Breaker LS

General Electric AKR-6D-75 low voltage power circuit breaker; 3200 amp frame, 600 volt, 3200 amp sensors. Electrically operated, closing voltage- 120 volt AC, operating range 104-127 volt, draw-out, Micro Versa Trip (TA9VT32MLA1) with LS functions. Used electrically OK.
SKU: AKR-6D-75 EMSCO #21741

AKR-5C-75 GE AIR BREAKER 3200A FRAME EO/DO LS

General Electric AKR-5C-75 low voltage power circuit breaker; 3200 amp frame, 3200 amp CT. Electric operated, draw-out, type ECS trip, LS functions, closing voltage: 120, range: 104-127 Vac. Used electrically OK.
SKU: AKR-5C-75 EMSCO #21072

Used and Refurbished Air Circuit Breakers

Air Circuit Breakers (ACB’s) use air to extinguish electrical sparks. When a fault occurs, these circuit breakers disrupt the circuit by releasing a burst of compressed air, extinguishing the arc. This isolates the defective section of the system, preventing damage. High-pressure air cools the electrical arc.

Inventory Selection of Air Circuit Breakers to Match and Replace Yours

Our inventory features a wide range of air circuit breaker types to match and replace your existing electrical equipment seamlessly, ensuring compatibility and optimal performance for different applications. Whether you need a specific voltage rating, current capacity, or unique design, we have options that suit your needs.

New and Refurbished Air Circuit Breakers -- It's Your Choice

We offer customers the flexibility to choose between new and refurbished ACB’s. New circuit breakers ensure the latest technology and warranties, while refurbished breakers provide cost-effective solutions without compromising quality, backed by thorough inspections and testing.

Electrical testing equipment Certifies Quality and Performance

Our products undergo rigorous electrical testing using the newest test equipment to guarantee quality, safety, and optimal performance. Each air circuit breaker is thoroughly inspected, ensuring it meets industry standards and specifications.

Specifications Based on Your Power Requirements

To specify the right air circuit breaker, consider power requirements such as voltage, current rating, breaking capacity, and the type of application. In most cases, air circuit breakers are used where there’s high risk of fire or explosion. Air Breakers are typically used for low voltages up to 15KV.

Our expert team can guide you through selecting the most suitable breaker for your specific power needs.

What Type of Air Circuit Breaker Do You Need?

Air Breaker Type

How the Breaker Type Works

Applications

Plain Break Air Breaker

Utilizes a pair of contacts within a chamber filled with air to interrupt the electrical circuit. When the contacts separate, an arc forms and is extinguished by the surrounding air.

Commonly used in low-voltage applications like residential and commercial settings, protecting against overcurrents and short circuits.

Magnetic Blowout Air Breaker

Uses a magnetic field to drive the arc away from the contacts, ensuring quick interruption and extinguishing of the arc. The magnetic force redirects the arc into a chute, effectively extinguishing it.

Often found in industrial and heavy-duty settings due to their capability to handle high fault currents, making them ideal for heavy machinery and large-scale equipment protection.

Air Chute Breaker

Uses a series of parallel plates to create a chute for the arc. When the contacts open, the arc is diverted into the chute, where it is elongated, cooled, and extinguished before being directed toward the exhaust vent.

Commonly applied in medium-voltage power distribution systems, particularly in substations, to protect transformers and other critical power equipment from faults and overloads.

Air Blast Breaker

Relies on a high-pressure air blast to extinguish the arc. The compressed air directed towards the arc causes rapid cooling and interruption, ensuring efficient breaking of the circuit.

Primarily utilized in high-voltage applications like power stations and critical infrastructure such as data centers and hospitals, offering reliable protection against high fault currents and maintaining system integrity.