Air Circuit Breakers

While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

150DHP500 Westinghouse 15KV 1200A EO/DO Porcel Line Air Breaker

Westinghouse 150DHP500 Porcel Line Breaker; 1200 amp rated, KV: 13.8 max. design KV: 15, BIL-KV: 95, cycles : 60, rated MVA 500, max. amps 25,000, mom. amps 60,000. Electrically Operated, draw-out, closing voltage range: 40-50 VDC, trip voltage : 48 VDC, motor volts: 48 VDC. Used as-is.
SKU: 150DHP500 EMSCO# 19552

15HK ITE 15KV 1200A EO/DO Air Circuit Breaker

ITE 15HK air circuit breaker; 1200 amp, 15KV rated, three pole. Control: 125 volt DC, electrically operated, draw-out. Sold used as-is **** No label on unit.
SKU: 15HK - EMSCO #19581

5-HK-3000 ITE Air Circuit Breaker - 5KV 3000A EO/DO

ITE Type: 5-HK-3000 Power circuit breaker; 4,160 VAC nominal, 4,760 VAC max, 3000 amp. Electrically operated, draw-out, 230 VAC, control voltage for charge and close, 48 VDC control voltage for trip. MFG Date 11/67, sold used electrically OK.
SKU: 5-HK-3000

75H-3 FPE Air Breaker 600V 3200A Electric Operated/Stationary Mount 120VAC

FPE 75H-3 Air Breaker; 600 volt, 3200 amp. Electric operated, stationary mount, 120 VAC, used sold electrically OK.
SKU: 75H-3 Emsco #22682

75H-3 FPE Air Breaker 600V 3200A Electric Operated/Stationary Mount 120VAC

FPE 75H-3 Air Breaker; 600 volt, 3200 amp. Electric operated, stationary mount, 120 VAC, #22683, used sold electrically OK.
SKU: 75H-3 Emsco #22683

AK-1-25 GE 600A Frame 600A Rated 600V MO/DO Air Circuit Breaker

General Electric AK-1-25 Air circuit breaker; 600 amp frame, 600 volt, 600 amp rated. Manually operated, draw-out series, over current tripping device, type EC-1, instantaneous function. Sold used electrically OK.
SKU: AK-1-25 EMSCO #21762

AE1B GE 600V 600A MO/DO LSI Function Air Breaker

General Electric AE1B Air Breaker; 600 volt, 600 amp, three pole. Manually operated, draw-out, LSI function, with door. Siemens-Allis LimiTrip trip, type- LTI, LSI functions. Sold used electrically OK.
SKU: AE1B EMSCO #21915

ABB 6 Terminal Simple Ground & Test Unit 3000A 5-15KV

ABB 6 Terminal Simple Ground & Test Unit; 3000 amp, 5-15 KV #23127, 3000 amps, 5-15 KV. Electrically operated, draw-out, serial# 1VAFACB48106004G09. Sold used electrically OK.
SKU: ABB-G&T-#23127

AE1B GE 600V 600A MO/DO LSI Function Air Breaker

General Electric AE1B Air Breaker; 600 volt, 600 amp. Manually operated, draw-out, LSI function, with door, 600 volts, 600 amps, three poles. Siemens-Allis LimiTrip trip, type- LTI, LSI functions. Used sold electrically OK. EMSCO #21909
SKU: AE1B EMSCO #21909

AE1B GE 600V 600A MO/DO LSI Function Air Breaker

General Electric AE1B; 600 volt, 600 amp, three pole. Manually operated, draw-out, LSI function, with door. Siemens-Allis LimiTrip trip, type- LTI, LSI functions. Used sold electrically OK. EMSCO #21910
SKU: AE1B EMSCO #21910

AE1B GE 600V 600A MO/DO LSI Function Air Breaker

General Electric AE1B Air Breaker; 600 volt, 600 amp, three pole. Manually operated, draw-out, with door. Siemens-Allis LimiTrip, trip type- LTI, LSI functions. Used sold electrically OK.
SKU: AE1B EMSCO #21914

50H-3 Federal Pioneer Air Breaker 2000A 600V MO/DO

Federal Pioneer 50H-3 Air circuit breaker; 2000 amp frame, 2000 amp trip, 600 volt, three pole. AC pro trip, type T361-V2, manually operated (120 volt AC), draw-out. Used electrically OK.
SKU: 50H-3 EMSCO#20804

50DHP350 Westinghouse Air Breaker 3000A 5KV EO/DO

Westinghouse 50DHP350 Air Breaker; 3000 amp, 5 KV, electrically operated, draw-out, motor volts: 230 AC, closing volts: 190-250 AC. Used sold electrically OK.
SKU: 50-DHP-350-EO-DO-#22756

50DHP350 Westinghouse Air Breaker 3000A 5KV EO/DO

Westinghouse 50DHP350 Air Breaker; 3000 amp, 5 KV, electrically operated, draw-out, closing volts: 190-250 AC. Used sold electrically OK.
SKU: 50-DHP-350-EO-DO-#21955

50DH250E WESTINGHOUSE 5KV 1200A EO/DO Air Breaker

Westinghouse 50DH250E air circuit breaker; 1200 amp, 5 KV rated. Electrically operated, draw-out, closing voltage: 125 volt DC, used as is.
SKU: 50DH250E-EMSCO #19937

50H-3 Federal Pioneer Air Breaker 2000A 600V MO/DO

Federal Pioneer 50H-3 Air circuit breaker; 2000 amp frame, 2000 amp trip, 600 volt, three pole. AC pro trip, type T361-V2, manual operated (120 volt AC), draw-out. Used electrically OK.
SKU: 50H-3 EMSCO#21046

50H-3 Federal Pioneer Air Breaker 2000A 600V MO/DO

Federal Pioneer 50H-3 Air circuit breaker; 2000 amp frame, 2000 amp trip, 600 volt, 800/1200/2000 amp CT, three pole. AC pro trip, manually operated, draw-out. Used electrically OK.
SKU: 50H-3 EMSCO#21396

50H-3 Federal Pioneer Air Breaker 2000A 600V MO/DO

Federal Pioneer 50H-3 Air circuit breaker; 2000 amp frame, 2000 amp trip, 600 volt, 800/1200/2000 amp CT, three pole. AC pro trip, manually operated, draw-out. Used electrically OK.
SKU: 50H-3 EMSCO#21441

50DHP250 WESTINGHOUSE 5KV 2000A EO/DO Air Circuit Breaker

Westinghouse 50DHP250 air circuit breaker; 2000 amp, 5 KV rated, electrically operated, draw-out. Used as is.
SKU: 50DHP250 - EMSCO # 19943

50DHP250 Westinghouse Air Breaker 2000A 5KV EO/DO

Westinghouse 50DHP250 Air Breaker; 2000 amp, 5 KV. Electrically operated, draw-over, closing volts: 190-250 AC, motor volts: 230 AC. Used sold electrically OK.
SKU: 50-DHP-250-EO-DO-#22770

Used and Refurbished Air Circuit Breakers

Air Circuit Breakers (ACB’s) use air to extinguish electrical sparks. When a fault occurs, these circuit breakers disrupt the circuit by releasing a burst of compressed air, extinguishing the arc. This isolates the defective section of the system, preventing damage. High-pressure air cools the electrical arc.

Inventory Selection of Air Circuit Breakers to Match and Replace Yours

Our inventory features a wide range of air circuit breaker types to match and replace your existing electrical equipment seamlessly, ensuring compatibility and optimal performance for different applications. Whether you need a specific voltage rating, current capacity, or unique design, we have options that suit your needs.

New and Refurbished Air Circuit Breakers -- It's Your Choice

We offer customers the flexibility to choose between new and refurbished ACB’s. New circuit breakers ensure the latest technology and warranties, while refurbished breakers provide cost-effective solutions without compromising quality, backed by thorough inspections and testing.

Electrical testing equipment Certifies Quality and Performance

Our products undergo rigorous electrical testing using the newest test equipment to guarantee quality, safety, and optimal performance. Each air circuit breaker is thoroughly inspected, ensuring it meets industry standards and specifications.

Specifications Based on Your Power Requirements

To specify the right air circuit breaker, consider power requirements such as voltage, current rating, breaking capacity, and the type of application. In most cases, air circuit breakers are used where there’s high risk of fire or explosion. Air Breakers are typically used for low voltages up to 15KV.

Our expert team can guide you through selecting the most suitable breaker for your specific power needs.

What Type of Air Circuit Breaker Do You Need?

Air Breaker Type

How the Breaker Type Works

Applications

Plain Break Air Breaker

Utilizes a pair of contacts within a chamber filled with air to interrupt the electrical circuit. When the contacts separate, an arc forms and is extinguished by the surrounding air.

Commonly used in low-voltage applications like residential and commercial settings, protecting against overcurrents and short circuits.

Magnetic Blowout Air Breaker

Uses a magnetic field to drive the arc away from the contacts, ensuring quick interruption and extinguishing of the arc. The magnetic force redirects the arc into a chute, effectively extinguishing it.

Often found in industrial and heavy-duty settings due to their capability to handle high fault currents, making them ideal for heavy machinery and large-scale equipment protection.

Air Chute Breaker

Uses a series of parallel plates to create a chute for the arc. When the contacts open, the arc is diverted into the chute, where it is elongated, cooled, and extinguished before being directed toward the exhaust vent.

Commonly applied in medium-voltage power distribution systems, particularly in substations, to protect transformers and other critical power equipment from faults and overloads.

Air Blast Breaker

Relies on a high-pressure air blast to extinguish the arc. The compressed air directed towards the arc causes rapid cooling and interruption, ensuring efficient breaking of the circuit.

Primarily utilized in high-voltage applications like power stations and critical infrastructure such as data centers and hospitals, offering reliable protection against high fault currents and maintaining system integrity.