Air Circuit Breakers

While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

VB1-4.16-250-2 GE 5KV 1200A EO/DO Air Circuit Breaker

General Electric VB1-4.16-250-2 power VAC circuit breaker; 1200 amp, 5 KV, three pole, control: 125 volt DC, electrically operated, draw-out. Sold used as-is.
SKU: VB1-4.16-250-2 - EMSCO # 19601

VV-1500 Siemens AC High-Voltage Air Circuit Breaker 1200A 38KV EO/DO

Siemens Type VV-1500 AC High-Voltage circuit breaker; rated max. volts: 38,000, rated amps: 1200, cycle: 60, voltage range K factor: 1.65, interrupting time cycle: 3, impulse level kV: 150, for use in IV-34 type switch gear. Electrically operated, draw out, with stored energy operator: type 515-4V, motor: 125 VDC, close voltage: 90-130 DC, trip voltage: 70-14 DC, close current (Nom.) 4.0 amps, trip current (Nom.) 4.0 amps, motor current (Nom.) 7.0 amps. Used electrically Okay.
SKU: VV-1500 #20239

VV-1500 Siemens AC High-Voltage Air Circuit Breaker 1200A 38KV EO/DO

Siemens Type VV-1500 AC High-Voltage circuit breaker; rated max. volts: 38,000, rated amps: 1200, cycle: 60, voltage range K factor: 1.65, interrupting time cycle: 3, impulse level kV: 150, for use in IV-34 type switchgear. Electrically operated, draw-out, with stored energy operator: type 515-4V motor: 125 VDC, close voltage: 90-130 DC, trip voltage: 70-14 DC, close current (Nom.) 4.0 amps, trip current (Nom.) 4.0 amps, motor current (Nom.) 7.0 amps. Used electrically Okay.
SKU: VV-1500 #20240

VV-1500 Siemens AC High-Voltage Air Circuit Breaker 1200A 38KV EO/DO

Siemens Type VV-1500 AC High-Voltage circuit breaker; rated max. volts: 38,000, rated amps: 1200, cycle: 60, voltage range K factor: 1.65, interrupting time cycle: 3, impulse level kV: 150, for use in IV-34 type switchgear. Electrically operated, draw-out, with stored energy operator: type 515-4V motor: 125 VDC, close voltage: 90-130 DC, trip voltage: 70-14 DC, close current (Nom.) 4.0 amps, trip current (Nom.) 4.0, amps motor current (Nom.) 7.0 amps. Used electrically Okay.
SKU: VV-1500 #20241

VV-1500 Siemens AC High-Voltage Air Circuit Breaker 1200A 38KV EO/DO

Siemens Type VV-1500 AC High-Voltage circuit breaker; rated max. volts: 38,000, rated amps: 1200, cycle: 60, voltage range K factor: 1.65, interrupting time cycle: 3, impulse level kV: 150, for use in IV-34 type switchgear. Electrically operated, draw-out, with stored energy operator: type 515-4V. Motor: 125 VDC, close voltage: 90-130 DC, trip voltage: 70-14 DC, close current (Nom.) 4.0 amps, trip current (Nom.) 4.0 amps, motor current (Nom.) 7.0 amps. Used electrically Okay.
SKU: VV-1500 #20242

100H-3 Federal Pioneer Air Breaker 4000A EO/DO LSIG w/cell

Federal Pioneer 100H-3 air circuit breaker; 4000 amp, electrically operated, draw-out. LSIG with cell #21903, 4000 amps, 600 volts, three poles, 120 VAC USR RMS over current relay LSIG functions, $8500 without cell. Used electrically OK.
SKU: 100H-3-EO/DO-LSIG-Emsco#21903

100H-3 Federal Pioneer 4000A Air Breaker EO/DO LSIG

Federal Pioneer 100H-3 air circuit breaker; 4000 amp, electrically operated, draw-out, LSIG with cell #21904, 4000 amps, 600 volts, three poles, 120 VAC USR RMS over current relay LSIG functions, $8500 without cell. Used electrically OK.
SKU: 100H-3-EO/DO-LSIG-Emsco#21904

100H-3 Federal Pioneer 4000A EO/DO Air Breaker LSIG w/cell

Federal Pioneer 100H-3 air circuit breaker; 4000 amp, LSIG with cell #21905, 4000 amps, 600 volts, three poles, 120 VAC, USR RMS over current relay LSIG functions, $8500 without cell. Electrically operated, draw-out. Used electrically OK.
SKU: 100H-3-EO/DO-LSIG-Emsco#21905

150 DHP 500 Westinghouse Air Breaker 1200A 15KV EO/DO

Westinghouse 150 DHP 500 Air breaker; 1200 amp, 15 KV, electrically operated, draw-out, #22670 closing volts: 90-130 DC. Used electrically OK.
SKU: 150DHP500-EO-DO-#22670

150 DHP 500 Westinghouse Air Breaker 1200A 15KV EO/DO

Westinghouse 150 DHP 500 Air Breaker; 1200 amp, 15 KV, electrically operated, draw-out, #22733 closing range: 40-50 DC, trip voltage: 48 DC. Used electrically OK.
SKU: 150DHP500-EO-DO-#22733

150DHP1000 Westinghouse Air Breaker 2000A 15KV EO/DO

Westinghouse 150DHP1000 Air Breaker; 2000 amp, 15 KV, electrically operated, draw-out, #22887, 125 DC motor volts. Used electrically OK.
SKU: 150DHP1000-#22887

150DHP1000 Westinghouse Air Breaker 2000A 15KV EO/DO

Westinghouse 150DHP1000 Air Breaker; 2000 amp, 15 KV, electrically operated, draw-out, #22883, 125 DC motor volts. Used electrically OK.
SKU: 150DHP1000-#22883

Westinghouse 150DHP1000 Air Breaker - 1200A, 15KV, Electrically Operated, Draw Out

Westinghouse 150DHP1000 Air Breaker; 1200 amp, 15 KV, electrically operated/draw-out, #22888, 125 DC motor volts. Used electrically OK.
SKU: 150DHP1000-#22888

150DHP1000 Westinghouse Air Breaker 1200A 15KV EO/DO

Westinghouse 150DHP1000 Air Breaker; 1200 amp, 15 KV, electrically operated, draw-out, #22886, 125 DC motor volts. Used electrically OK.
SKU: 150DHP1000-#22886

150DHP1000 Westinghouse Air Breaker 1200A 15KV EO/DO

Westinghouse 150DHP1000 Air Breaker; 1200 amp, 15 KV, electrically operated, draw-out, #22882, 125 VDC motor volts. Used electrically OK.
SKU: 150DHP1000-#22882

150DHP1000 Westinghouse Air Breaker 1200A 15KV EO/DO

Westinghouse 150DHP1000 Air Breaker; 1200 amp, 15 KV, electrically operated, draw-out, #22881, 125 VDC motor volts. Used electrically OK.
SKU: 150DHP1000-#22881

150DH1000E Westinghouse Air Breaker 15KV 1200A EO/DO

Westinghouse 150DH1000E Air Breaker; 15 KV, 1200 amp, electrically operated, draw-out, #23009, 125 DC closing volts, SE2A type mechanism. Used electrically OK.
SKU: 150DH1000E-#23009

150DH1000E Westinghouse Air Breaker 15KV 1200A EO/DO

Westinghouse 150DH1000E Air Breaker; 15 KV, 1200 amp, electrically operated, draw-out, #23008, 125 DC closing volts, SE2A type mechanism. Used electrically operated.
SKU: 150DH1000E-#23008

50H-3 Federal Pioneer Air Breaker 2000 Amp 600 Volt MO/DO

Federal Pioneer 50H-3 Air circuit breaker; 2000 amp frame, 2000 amp trip, 600 volt, three pole, AC pro trip type T361-V2, manually operated (120 volt AC), draw-out. Used electrically OK.
SKU: 50H-3 EMSCO#20805

50H-3 Federal Pioneer Air Breaker 2000A 600V MO/DO

Federal Pioneer 50H-3 Air circuit breaker; 2000 amp frame, 2000 amp trip, 600 volt, three pole, AC pro trip type T361-V2, manually operated, (120 volt AC), draw-out. Used electrically OK.
SKU: 50H-3 EMSCO#20806

Used and Refurbished Air Circuit Breakers

Air Circuit Breakers (ACB’s) use air to extinguish electrical sparks. When a fault occurs, these circuit breakers disrupt the circuit by releasing a burst of compressed air, extinguishing the arc. This isolates the defective section of the system, preventing damage. High-pressure air cools the electrical arc.

Inventory Selection of Air Circuit Breakers to Match and Replace Yours

Our inventory features a wide range of air circuit breaker types to match and replace your existing electrical equipment seamlessly, ensuring compatibility and optimal performance for different applications. Whether you need a specific voltage rating, current capacity, or unique design, we have options that suit your needs.

New and Refurbished Air Circuit Breakers -- It's Your Choice

We offer customers the flexibility to choose between new and refurbished ACB’s. New circuit breakers ensure the latest technology and warranties, while refurbished breakers provide cost-effective solutions without compromising quality, backed by thorough inspections and testing.

Electrical testing equipment Certifies Quality and Performance

Our products undergo rigorous electrical testing using the newest test equipment to guarantee quality, safety, and optimal performance. Each air circuit breaker is thoroughly inspected, ensuring it meets industry standards and specifications.

Specifications Based on Your Power Requirements

To specify the right air circuit breaker, consider power requirements such as voltage, current rating, breaking capacity, and the type of application. In most cases, air circuit breakers are used where there’s high risk of fire or explosion. Air Breakers are typically used for low voltages up to 15KV.

Our expert team can guide you through selecting the most suitable breaker for your specific power needs.

What Type of Air Circuit Breaker Do You Need?

Air Breaker Type

How the Breaker Type Works

Applications

Plain Break Air Breaker

Utilizes a pair of contacts within a chamber filled with air to interrupt the electrical circuit. When the contacts separate, an arc forms and is extinguished by the surrounding air.

Commonly used in low-voltage applications like residential and commercial settings, protecting against overcurrents and short circuits.

Magnetic Blowout Air Breaker

Uses a magnetic field to drive the arc away from the contacts, ensuring quick interruption and extinguishing of the arc. The magnetic force redirects the arc into a chute, effectively extinguishing it.

Often found in industrial and heavy-duty settings due to their capability to handle high fault currents, making them ideal for heavy machinery and large-scale equipment protection.

Air Chute Breaker

Uses a series of parallel plates to create a chute for the arc. When the contacts open, the arc is diverted into the chute, where it is elongated, cooled, and extinguished before being directed toward the exhaust vent.

Commonly applied in medium-voltage power distribution systems, particularly in substations, to protect transformers and other critical power equipment from faults and overloads.

Air Blast Breaker

Relies on a high-pressure air blast to extinguish the arc. The compressed air directed towards the arc causes rapid cooling and interruption, ensuring efficient breaking of the circuit.

Primarily utilized in high-voltage applications like power stations and critical infrastructure such as data centers and hospitals, offering reliable protection against high fault currents and maintaining system integrity.