Molded & Insulated Case Circuit Breakers

Currently shopping by:
  • Functions: LIG - Long-Time, Instantaneous, Ground
Remove Filter
While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

TPVVF3608 GE Power Break Breaker 800 Amp 600 VAC M/O D/O

General Electric TPVVF3608 Power Break Circuit Breaker; 800 amp, 600 volt AC, 3 pole. With Micro Versa Trip cat.#TP9V20GA3, LIG functions, ground fault, manually operated (M/O), draw-out (D/O), used tested with report.
SKU: MCCB1367

TPVVF3608 GE Power Break Breaker 800 Amp 600 VAC M/O D/O LIG

General Electric TPVVF3608 Power Break Circuit Breaker; 800 amp, 600 volt AC, 3 pole. With Micro Versa Trip, Cat.#TP9VT20GA3, LIG functions, manually operated (M/O), draw-out (D/O), draw-out carriage assembly, used tested with report.
SKU: MCCB1110

TPVVF3608 GE Power Break Breaker 800 Amp 600 VAC M/O D/O LIG

Generic Electric TPVVF3608 Power Break Circuit Breaker; 800 amp, 600 volt AC, 3 pole. With Micro Versa Trip cat.#TP9VT20GA3, LIG functions, manually operated (M/O), draw-out (D/O), draw-out carriage assembly, used tested with report.
SKU: MCCB1111

TPVVF5610 GE Power Break Breaker 1000 Amp 600 VAC M/O D/O

General Electric TPVVF5610 Power Break Circuit Breaker; 1000 amp, 600 volt AC, 3 pole. With Micro Versa trip cat.#TP9VT20GA3, LIG functions, ground fault, manually operated (M/O), draw-out (D/O), used tested with report.
SKU: MCCB1369

TPVVF5610 GE Power Break Breaker 1000 Amp 600 VAC LIG M/O D/O

General Electric TPVVF5610 Power Break Circuit Breaker; 1000 amp, 600 volt AC, 3 pole. With Micro Versa trip cat.# TP9VT20GA3, LIG functions, ground fault, manually operated (M/O), draw-out (D/O), used tested with report.
SKU: MCCB1370

TPSS7625G GE Power Break Breaker 2500 Amp VersaTrip 600 VAC

General Electric TPSS7625G Power Break Circuit Breaker; 2500 amp, 600 volt AC, 3 pole. With VersaTrip, LIG functions, ground fault, manually operated (M/O), used tested with report.
SKU: MCCB1040

TPVVF3608 GE Power Break Breaker 800 Amp 600 VAC M/O D/O

General Electric TPVVF3608 Power Break Circuit Breaker; 800 amp, 600 volt AC, 3 pole. With Micro Versa Trip cat.#TP9VT20GA3, LIG functions, ground fault, manually operated (M/O), draw-out (D/O), used tested with report.
SKU: MCCB1372

TPVVF3608 GE Power Break Breaker 800 Amp 600 VAC M/O D/O

General Electric TPVVF3608 Power Break Circuit Breaker; 800 amp, 600 volt AC, 3 pole. With Micro Versa Trip cat.#TP9VT20GA3, LIG functions, ground fault, manually operated (M/O), draw-out (D/O), used tested with report.
SKU: MCCB1368

TPVVF3608 GE Power Break Breaker 800 Amp 600 VAC M/O D/O

General Electric TPVVF3608 Power Break Circuit Breaker; 800 amp, 600 volt AC, 3 pole. With Micro Versa Trip cat.#TP9VT20GA3, LIG functions, ground fault, manually operated (M/O), draw-out (D/O), used tested with report.
SKU: MCCB1373

TPSS4612G GE Power Break Breaker 1200 Amp 600 VAC M/O D/O

General Electric TPSS4612G Power Break Circuit Breaker; 1200 amp, 600 volt AC, 3 pole. With solid state Versa Trip, LIG functions, ground fault, 600 volt AC, manually operated (M/O), draw-out (D/O), used tested with report.
SKU: MCCB1109

TPVVF3608 GE Power Break Breaker 800 Amp 600 VAC M/O D/O

General Electric TPVVF3608 Power Break Circuit Breaker; 800 amp, 600 volt AC, 3 pole. With Micro Versa Trip cat.#TP9V20GA3, LIG functions, ground fault, manually operated (M/O), draw-out (D/O), used tested with report.
SKU: MCCB1366

TPVVF3608 GE Power Break Breaker 800 Amp M/O D/O 600 VAC

General Electric TPVVF3608 Power Break Circuit Breaker; 800 amp, 600 volt AC, 3 pole. With Micro Versa Trip cat.#TP9VT20GA3, LIG functions, ground fault, manually operated (M/O), draw-out (D/O), used tested with report.
SKU: MCCB1374

TPSS6616G3BFC GE Power Break Breaker 1600 Amp 600 VAC M/O

General Electric TPSS6616G3BFC Power Break Circuit Breaker; 1600 amp, 600 volt AC, 3 pole. With solid state Versa Trip, LIG functions, ground fault, manually operated (M/O), used tested with report.
SKU: MCCB1137

SPB100 Westinghouse Pow-R-Way Breaker 2500 Amp 600 VAC E/O D/O

Westinghouse SPB100 Pow-R-Way breaker; 2500 amp, 600 volt AC, 3 pole. With Digitrip RMS 600 cat.# T64ALIG, LIG functions, ground fault, 2500 amp rating plug cat.# PD6S25A250, shunt trip cat.# SPBSTEO024D- 24 VDC-8.0 @ .25 sec. DC, E/O (electrically operated)- cat.# SPBEO120A 120 VAC- 1.2 amps, 50/60 Hz, spring release- 120 VAC--2.5 amps, 50/60 Hz. D/O ( draw out), used tested with report.
SKU: MCCB1717

SPB100 Westinghouse Pow-R-Way Breaker 1600 Amp 600 VAC M/O D/O

Westinghouse SPB100 Pow-R-Way breaker; 1600 amp Digitrip RMS 500 trip unit with LIG functions, cat.#T54BLIG with 1600 amp rating plug. Cat.# PD6516A160, 600 volt AC, manually operated (M/O), draw-out (D/O), used tested with report.
SKU: MCCB1500

TC2020SS GE Power Break Breaker 2000 Amp 600 VAC M/O D/O

General Electric TC2020SS Power Break circuit breaker; 2000 amp, 600 volt AC, 3 pole. With Micro Versa Trip RMS-9, LIG, ground fault, 2000 amp rating plug cat.# TR20S2000, manually operated (M/O), draw out (D/O), draw-out carriage cat.# TDOS20, used tested with report.
SKU: MCCB1662

TC2020SS GE Power Break Breaker 2000 Amp 600 VAC M/O D/O

General Electric TC2020SS Power Break circuit breaker; 2000 amp, 600 volt AC, 3 pole. With Micro Versa Trip RMS-9, LIG, ground fault, 2000 amp rating plug cat.# TR20S2000, manually operated (M/O), draw-out (D/O), draw-out carriage cat.# TDOS20, used tested with report.
SKU: MCCB1661

TC2020SS GE Power Break Circuit Breaker 2000 Amp 600 VAC M/O D/O

General Electric TC2020SS Power Break Circuit Breaker; 2000 amp, 600 volt AC, 3 pole. With RMS-9 Micro Versa Trip cat.# TS20LIG, LIG functions, ground fault, 2000 amp rating plug cat.# TR20S2000, manually operated (M/O), draw out (D/O), draw-out carriage cat.# TDOS20, used tested with report.
SKU: MCCB1637

THCVF7616 GE Power Break Breaker 1600 Amp 600 VAC M/O D/O

General Electric THCVF7616 Power Break; 1600 amp, 600 volt AC, 3 pole. With Micro Versa Trip cat.# TP4VT25G, LIG, ground fault, manually operated (M/O), draw-out (D/O), used tested with report.
SKU: MCCB1433

THCVF7616 GE Power Break Breaker 1600 Amp 600 VAC M/O D/O

General Electric THCVF7616 Power Break Circuit Breaker; 1600 amp, 600 volt AC, 3 pole. With Micro Versa Trip cat.# TP4VT25G, LIG functions, ground fault, manually operated (M/O), draw-out (D/O), used tested with report.
SKU: MCCB1434

New, Used, and Tested Molded & Insulated Case Circuit Breakers

EMSCO has been specializing in used and refurbished molded & insulated case circuit breakers for over 72 years.


Why Choose EMSCO for Molded Case or Insulated Case Circuit Breakers?

Want to match and replace your existing breakers? End the hassle of retrofitting your electrical system. Our extensive inventory includes a variety of Molded Case Circuit Breakers (MCCBs) and Insulated Case Circuit Breakers that are designed to seamlessly match and replace your existing breakers by brand, amp rating, voltage, frame size, or model.

New and Refurbished Products in Stock

We understand that budgets and preferences differ, so we give you the option of selecting between new and refurbished MCCBs or Insulated Case Breakers, both of which are readily available in our inventory. Choose brand-new circuit breakers for maximum performance and longevity, or look into our refurbished options, which have been rigorously tested and reconditioned to meet industry standards.

Popular Brands and Common Configurations

Our shelves are stocked with breakers from the most trusted and popular brands in the industry, ensuring you have access to dependable products. You'll find common configurations, such as different frame sizes and voltage ratings, making it simple to find the right circuit protection for your application.

Avoiding Costly Operational Downtime

Downtime can be an expensive situation. Our circuit protection products are designed for high performance and durability. You can avoid costly operational downtime due to electrical failures by using our fully-tested Molded Case or Insulated Case breakers. Our products provide reliable power and superior equipment protection.

Electrical Testing Equipment Certifying Quality and Performance

When it comes to the dependability and safety of your electrical systems, we leave nothing to chance. Our breakers are rigorously tested using current testing equipment to ensure that they meet or exceed industry standards. This ensures that your electrical installations are safe and efficient.

  • Overcurrent Protection: We verify that your breakers provide accurate overcurrent protection, guaranteeing the safety of your electrical systems.
  • Trip Time: We measure the time it takes for breakers to respond to overcurrent conditions, ensuring it operates within the specified trip time.
  • Short-Circuit Withstand Capacity: Our testing evaluates the breaker’s ability to withstand short-circuit currents, preventing damage and maintaining safety.
  • Interrupting Capacity: We determine the MCCB's capability to interrupt fault currents, ensuring the utmost protection for your electrical system.

Molded Case Circuit Breaker Specifications

A sample table of ampere ratings, corresponding voltage ratings, and frame sizes for molded case circuit breakers is shown below. Please keep in mind that frame sizes and ratings can differ between manufacturers and models. For precise details on a specific MCCB, always refer to the manufacturer's specifications.

Frame Size

Ampere Rating

Voltage Rating

A

15A

120V, 240V

A

20A

120V, 240V

B

30A

120V, 240V, 480V

B50A120V, 240V, 480V
C60A240V, 480V
C100A240V, 480V
D150A240V, 480V, 600V
D200A240V, 480V, 600V
E250A240V, 480V, 600V
E300A240V, 480V, 600V
F400A240V, 480V, 600V
F600A240V, 480V, 600V
G800A240V, 480V, 600V
G1200A240V, 480V, 600V
H1600A240V, 480V, 600V

This table is a sample representation of frame sizes, ampere ratings, and voltage ratings for Molded Case Circuit Breakers, not an exhaustive list.

Molded case circuit breakers (MCCBs) and insulated case circuit breakers (ICCBs) are two distinct types of circuit protection devices used in electrical systems. Both serve the purpose of interrupting electrical currents in case of faults or overloads, but they differ in construction, application, and performance characteristics. Need Help Now? Call 800-328-1842.