While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

THSS6620DFCE1 GE Power Break 2000 Amp 600 VAC E/O D/O

General Electric THSS6620DFCE1 Power Break circuit breaker: 2000 amp, 600 volt AC, 3 pole. With AC-Pro, solid state versa trip unit mod.2, LS functions, shunt trip- 24 VDC, auxiliary switch, control voltage- 120 volt AC, electrically operated (E/O), draw-out (D/O), power break, draw-out frame cat.# THDF20. Used tested with report.
SKU: MCCB1537

TC88TTHE1R GE Power Break Breaker 800 Amp 600 VAC W/Aux.'s E/O W/Shunt

General Electric TC88TTHE1R Power Break Circuit Breaker; 800 amp, 600 volt AC, 3 pole. With 800 amp rating plug cat.# TR8B800, Micro Versa Trip cat.# C208LSHMR, auxiliary switch, shunt trip- 48 volt D.C., electrically operated (E/O), control voltage- 120 volt AC, draw-out (D/O), used tested with report.
SKU: MCCB1019

CND3800T33W Cutler-Hammer Circuit Breaker

Cutler-Hammer CND3800T33W circuit breaker; 800 amp, 600 volt, three pole, 50 kAIC @ 480 volt AC with LS. 400, 450, 500, 600, 700 and 800 amp trips available, used tested with report.
SKU: CND3800T33W
Contact us for pricing:

CHND212T33W Cutler-Hammer Circuit Breaker

Cutler-Hammer CHND212T33W circuit breaker; 1200 amp, 600 volt, two pole, 65 kAIC @ 480 volt AC with LS. 600, 700, 800, 900, 1000 and 1200 amp trips available, used electronically OK.
SKU: CHND212T33W
Contact us for pricing:

CHND2800T33W Cutler-Hammer Circuit Breaker

Cutler-Hammer CHND2800T33W circuit breaker; 800 amp, 600 volt, two pole, 65 kAIC @ 480 volt AC with LS. 400, 450, 500, 600, 700 and 800 amp trips available, used electronically OK.
SKU: CHND2800T33W
Contact us for pricing:

SPB100 Westinghouse Pow-R Breaker 2000 Amp 600 VAC E/O

Westinghouse SPB100 Pow-R breaker; 2000 amp, 600 volt AC, 3 pole. With 2000 amp rating plug cat.#PD6S20A200, Digitrip RMS 600 cat.#T63CLS, LS functions, electrically operated (E/O)- cat.#SPBEO120A 120 volt AC, shunt trip- cat.#SPBSTEO024D 24 volt DC, under voltage release cat.#SPBUV024D 24 volt DC, auxiliary switch cat.#SPBAUX304, spring release- 120 volt AC, power relay module 120 volt AC, used tested with report.
SKU: MCCB1159

CHND312T33W Cutler-Hammer Circuit Breaker

Cutler-Hammer CHND312T33W circuit breaker; 1200 amp, 600 volt, three pole, 65 kAIC @ 480 volt AC with LS. 600, 700, 800, 900, 1000 and 1200 amp trips available, used tested with report.
SKU: CHND312T33W
Contact us for pricing:

SPB100 Westinghouse Pow-R Breaker 2000 Amp 600 VAC E/O

Westinghouse SPB100 Pow-R Breaker; 2000 amp, 600 volt AC, 3 pole. With 2000 amp rating plug cat.# PD6S20A200, Digitrip RMS 600 cat.# T63BLS, LS functions, electrically operated (E/O)- cat.#SPBEO120A 120 volt AC, shunt trip- cat.# SPBSTEO024D 24 volt DC, auxiliary switch cat.#SPBAUX304, spring release- 120 volt AC, power relay module 120 volt AC, used tested with report.
SKU: MCCB1160

SPB100 Westinghouse Pow-R Breaker 2000 Amp 600 VAC E/O

Westinghouse SPB100 Pow-R Breaker; 2000 amp, 600 volt AC, 3 pole. With 2000 amp rating plug cat.#PD6S20A200, Digitrip RMS 600 cat.#T63CLS, LS functions, shunt trip cat.#SPBSTEO024D, auxiliary switch cat.#SPBAUX304, under voltage release cat.#SPBUV024D 24 volt DC, power relay module-120 volt AC, spring release- 120 volt AC, electrically operated (E/O) cat.#SPBEO120A- 120 volt AC, used tested with report.
SKU: MCCB1170

CHND3800T33W Cutler-Hammer Circuit Breaker

Cutler-Hammer CHND3800T33W circuit breaker; 800 amp, 600 volt, three pole, 65 kAIC @ 480 volt AC with LS. 400, 450, 500, 600, 700 and 800 amp trips available, used tested with report.
SKU: CHND3800T33W
Contact us for pricing:

CND212T33W Cutler-Hammer Circuit Breaker

Cutler-Hammer CND212T33W circuit breaker; 1200 amp, 600 volt, two pole, 50 kAIC @ 480 volt AC with LS. 600, 700, 800, 900, 1000 and 1200 amp trips available, used electronically OK.
SKU: CND212T33W
Contact us for pricing:

CND2800T33W Cutler-Hammer Circuit Breaker

Cutler-Hammer CND2800T33W circuit breaker; 800 amp, 600 volt, two pole, 50 kAIC @ 480 volt AC with LS. 400, 450, 500, 600, 700 and 800 amp trips available, used electronically OK.
SKU: CND2800T33W
Contact us for pricing:

CND312T33W Cutler-Hammer Circuit Breaker

Cutler-Hammer CND312T33W circuit breaker; 1200 amp, 600 volt, three pole, 50 kAIC @ 480 volt AC with LS. 600, 700, 800, 900, 1000 and 1200 amp trips available, used tested with report.
SKU: CND312T33W

SPB100 Westinghouse Pow-R Breaker 2000 Amp 600 VAC E/O

Westinghouse SPB100 Pow-R breaker; 2000 amp, 600 volt AC, 3 pole. With 2000 amp rating plug cat.#PD6S20A200, Digitrip RMS 600 cat.#T63CLS, LS functions, shunt trip cat.#SPBSTEO024D, auxiliary switch cat.#SPBAUX304, power relay module- 120 VAC, spring release- 120 VAC, electrically operated (E/O)- cat.#SPBEO120A 120 VAC, used tested with report.
SKU: MCCB1169

SPB100 Westinghouse Pow-R Breaker 2000 Amp 600 VAC E/O F/M

Westinghouse SPB100 Pow-R breaker; 2000 amp, 600 volt AC, 3 pole. With Digitrip RMS600 trip unit cat.# T63CLS, 2000 amp rating plug cat.# PD6S20A200, shunt trip cat.# SPBSTEO024D, aux. switch cat.# SPAUX304, electrical operator cat.# SPBEO120A, under voltage release cat.# SPBUV024D, electrically operated (E/O), fixed mount (F/M), used tested with report.
SKU: MCCB1799
Contact us for pricing:

SPB100 Westinghouse Pow-R Breaker 2000 Amp 600 VAC E/O F/M

Westinghouse SPB100 Pow-R breaker; 2000 amp Digitrip RMS600 trip unit, cat.# T63CLS 2000 amp rating plug. Cat.# PD6S20A200 shunt trip, cat.# SPBSTEO024D aux. switch, cat.# SPAUX304 elect. operator, cat.# SPBEO120A 600 VAC electrically operated (E/O), fixed mount (F/M), used tested with report.
SKU: MCCB1800
Contact us for pricing:

SED361600LS Square D Breaker 1600 Amp 600 VAC

Square D SED361600LS breaker; 1600 amp, 600 volt AC, 3 pole. With 1600 amp rating plug cat.# ARP100, micro logic full function series B trip unit, used tested with report.
SKU: MCCB1360

HND212T33W Cutler-Hammer Circuit Breaker

Cutler-Hammer HND212T33W circuit breaker; 1200 amp, 600 volt, two pole, 65 kAIC @ 480 volt AC with LS. 600, 700, 800, 900, 1000 and 1200 amp trips available, used electrically OK.
SKU: HND212T33W
Contact us for pricing:

HND2800T33W Cutler-Hammer Circuit Breaker

Cutler-Hammer HND2800T33W circuit breaker; 800 amp, 600 volt, two pole, 65 kAIC @ 480 volt AC with LS. 400, 450, 500, 600, 700 and 800 amp trips available, used electrically OK.
SKU: HND2800T33W
Contact us for pricing:

HND312T33W Cutler-Hammer Circuit Breaker

Cutler-Hammer HND312T33W circuit breaker; 1200 amp, 600 volt, three pole, 65 kAIC @ 480 volt AC with LS. 600, 700, 800, 900, 1000 and 1200 amp trips available, line & load side lugs. Used tested with report.
SKU: HND312T33W

New, Used, and Tested Molded & Insulated Case Circuit Breakers

EMSCO has been specializing in used and refurbished molded & insulated case circuit breakers for over 72 years.


Why Choose EMSCO for Molded Case or Insulated Case Circuit Breakers?

Want to match and replace your existing breakers? End the hassle of retrofitting your electrical system. Our extensive inventory includes a variety of Molded Case Circuit Breakers (MCCBs) and Insulated Case Circuit Breakers that are designed to seamlessly match and replace your existing breakers by brand, amp rating, voltage, frame size, or model.

New and Refurbished Products in Stock

We understand that budgets and preferences differ, so we give you the option of selecting between new and refurbished MCCBs or Insulated Case Breakers, both of which are readily available in our inventory. Choose brand-new circuit breakers for maximum performance and longevity, or look into our refurbished options, which have been rigorously tested and reconditioned to meet industry standards.

Popular Brands and Common Configurations

Our shelves are stocked with breakers from the most trusted and popular brands in the industry, ensuring you have access to dependable products. You'll find common configurations, such as different frame sizes and voltage ratings, making it simple to find the right circuit protection for your application.

Avoiding Costly Operational Downtime

Downtime can be an expensive situation. Our circuit protection products are designed for high performance and durability. You can avoid costly operational downtime due to electrical failures by using our fully-tested Molded Case or Insulated Case breakers. Our products provide reliable power and superior equipment protection.

Electrical Testing Equipment Certifying Quality and Performance

When it comes to the dependability and safety of your electrical systems, we leave nothing to chance. Our breakers are rigorously tested using current testing equipment to ensure that they meet or exceed industry standards. This ensures that your electrical installations are safe and efficient.

  • Overcurrent Protection: We verify that your breakers provide accurate overcurrent protection, guaranteeing the safety of your electrical systems.
  • Trip Time: We measure the time it takes for breakers to respond to overcurrent conditions, ensuring it operates within the specified trip time.
  • Short-Circuit Withstand Capacity: Our testing evaluates the breaker’s ability to withstand short-circuit currents, preventing damage and maintaining safety.
  • Interrupting Capacity: We determine the MCCB's capability to interrupt fault currents, ensuring the utmost protection for your electrical system.

Molded Case Circuit Breaker Specifications

A sample table of ampere ratings, corresponding voltage ratings, and frame sizes for molded case circuit breakers is shown below. Please keep in mind that frame sizes and ratings can differ between manufacturers and models. For precise details on a specific MCCB, always refer to the manufacturer's specifications.

Frame Size

Ampere Rating

Voltage Rating

A

15A

120V, 240V

A

20A

120V, 240V

B

30A

120V, 240V, 480V

B50A120V, 240V, 480V
C60A240V, 480V
C100A240V, 480V
D150A240V, 480V, 600V
D200A240V, 480V, 600V
E250A240V, 480V, 600V
E300A240V, 480V, 600V
F400A240V, 480V, 600V
F600A240V, 480V, 600V
G800A240V, 480V, 600V
G1200A240V, 480V, 600V
H1600A240V, 480V, 600V

This table is a sample representation of frame sizes, ampere ratings, and voltage ratings for Molded Case Circuit Breakers, not an exhaustive list.

Molded case circuit breakers (MCCBs) and insulated case circuit breakers (ICCBs) are two distinct types of circuit protection devices used in electrical systems. Both serve the purpose of interrupting electrical currents in case of faults or overloads, but they differ in construction, application, and performance characteristics. Need Help Now? Call 800-328-1842.