Molded & Insulated Case Circuit Breakers

Currently shopping by:
  • Manufacturer: Westinghouse
  • Amperage: 90
Remove Filter
While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

EB1090 Westinghouse Circuit Breaker

Westinghouse EB1090 circuit breaker; 90 amp, 120 volt, single pole, used electronically OK.
SKU: EB1090
Contact us for pricing:

EB2090 Westinghouse Circuit Breaker

Westinghouse EB2090 circuit breaker; 90 amp, 240 volt, two pole, used electronically OK.
SKU: EB2090
Contact us for pricing:

EB3090 Westinghouse Circuit Breaker

Westinghouse EB3090 circuit breaker; 90 amp, 240 volt, three pole, load side lugs. Used electronically OK.
SKU: EB3090

EHB1090 Westinghouse Circuit Breaker

Westinghouse EHB1090 circuit breaker; 90 amp, 277 volt, single pole, used electronically OK.
SKU: EHB1090
Contact us for pricing:

EHB2090 Westinghouse Circuit Breaker

Westinghouse EHB2090 circuit breaker; 90 amp, 480 volt, two pole, load side lugs. Used electronically OK.
SKU: EHB2090
Contact us for pricing:

EHB3090 Westinghouse Circuit Breaker

Westinghouse EHB3090 circuit breaker; 90 amp, 480 volt, three pole, line & load side lugs. Used tested with report.
SKU: EHB3090

FB2090 Westinghouse Circuit Breaker

Westinghouse FB2090 circuit breaker; 90 amp, 600 volt, two pole, load side lugs. Used electronically OK.
SKU: FB2090
Contact us for pricing:

FB3090 Westinghouse Circuit Breaker

Westinghouse FB3090 circuit breaker; 90 amp, 600 volt, three pole, load side lugs. Used tested with report.
SKU: FB3090

HFB1090 Westinghouse Circuit Breaker

Westinghouse HFB1090 circuit breaker; 90 amp, 277 volt, single pole, used electrically OK.
SKU: HFB1090
Contact us for pricing:

HFB2090 Westinghouse Circuit Breaker

Westinghouse HFB2090 circuit breaker; 90 amp, 600 volt, two pole, load side lugs. Used electrically OK.
SKU: HFB2090
Contact us for pricing:

HFB3090 Westinghouse Circuit Breaker

Westinghouse HFB3090 circuit breaker; 90 amp, 600 volt, three pole, line & load side lugs. Used tested with report.
SKU: HFB3090

HKB3090 Westinghouse Circuit Breaker

Westinghouse HKB3090 circuit breaker; 90 amp, 600 volt, three pole, line & load side lugs. Used tested with report.
SKU: HKB3090

HKB2090 Westinghouse Circuit Breaker

Westinghouse HKB2090 circuit breaker; 90 amp, 600 volt, two pole, used electrically OK.
SKU: HKB2090
Contact us for pricing:

JB2090 Westinghouse Circuit Breaker

Westinghouse JB2090 circuit breaker; 90 amp, 600 volt, two pole, used electrically OK.
SKU: JB2090
Contact us for pricing:

JB3090 Westinghouse Circuit Breaker

Westinghouse JB3090 circuit breaker; 90 amp, 600 volt, three pole, line & load side lugs. Used tested with report.
SKU: JB3090

KA3090 Westinghouse Circuit Breaker

Westinghouse KA3090 circuit breaker; 90 amp, 600 volt, three pole, used tested with report.
SKU: KA3090

KB2090 Westinghouse Circuit Breaker

Westinghouse KB2090 circuit breaker; 90 amp, 600 volt, two pole, used electrically OK.
SKU: KB2090
Contact us for pricing:

KB3090 Westinghouse Circuit Breaker

Westinghouse KB3090 circuit breaker; 90 amp, 600 volt, three pole, used tested with report.
SKU: KB3090
Contact us for pricing:

LB2090 Westinghouse Circuit Breaker

Westinghouse LB2090 circuit breaker; 90 amp, 600 volt, two pole, used electrically OK.
SKU: LB2090
Contact us for pricing:

LB3090 Westinghouse Circuit Breaker

Westinghouse LB3090 circuit breaker; 90 amp, 600 volt, three pole, line & load side lugs. Used tested with report.
SKU: LB3090

New, Used, and Tested Molded & Insulated Case Circuit Breakers

EMSCO has been specializing in used and refurbished molded & insulated case circuit breakers for over 72 years.


Why Choose EMSCO for Molded Case or Insulated Case Circuit Breakers?

Want to match and replace your existing breakers? End the hassle of retrofitting your electrical system. Our extensive inventory includes a variety of Molded Case Circuit Breakers (MCCBs) and Insulated Case Circuit Breakers that are designed to seamlessly match and replace your existing breakers by brand, amp rating, voltage, frame size, or model.

New and Refurbished Products in Stock

We understand that budgets and preferences differ, so we give you the option of selecting between new and refurbished MCCBs or Insulated Case Breakers, both of which are readily available in our inventory. Choose brand-new circuit breakers for maximum performance and longevity, or look into our refurbished options, which have been rigorously tested and reconditioned to meet industry standards.

Popular Brands and Common Configurations

Our shelves are stocked with breakers from the most trusted and popular brands in the industry, ensuring you have access to dependable products. You'll find common configurations, such as different frame sizes and voltage ratings, making it simple to find the right circuit protection for your application.

Avoiding Costly Operational Downtime

Downtime can be an expensive situation. Our circuit protection products are designed for high performance and durability. You can avoid costly operational downtime due to electrical failures by using our fully-tested Molded Case or Insulated Case breakers. Our products provide reliable power and superior equipment protection.

Electrical Testing Equipment Certifying Quality and Performance

When it comes to the dependability and safety of your electrical systems, we leave nothing to chance. Our breakers are rigorously tested using current testing equipment to ensure that they meet or exceed industry standards. This ensures that your electrical installations are safe and efficient.

  • Overcurrent Protection: We verify that your breakers provide accurate overcurrent protection, guaranteeing the safety of your electrical systems.
  • Trip Time: We measure the time it takes for breakers to respond to overcurrent conditions, ensuring it operates within the specified trip time.
  • Short-Circuit Withstand Capacity: Our testing evaluates the breaker’s ability to withstand short-circuit currents, preventing damage and maintaining safety.
  • Interrupting Capacity: We determine the MCCB's capability to interrupt fault currents, ensuring the utmost protection for your electrical system.

Molded Case Circuit Breaker Specifications

A sample table of ampere ratings, corresponding voltage ratings, and frame sizes for molded case circuit breakers is shown below. Please keep in mind that frame sizes and ratings can differ between manufacturers and models. For precise details on a specific MCCB, always refer to the manufacturer's specifications.

Frame Size

Ampere Rating

Voltage Rating

A

15A

120V, 240V

A

20A

120V, 240V

B

30A

120V, 240V, 480V

B50A120V, 240V, 480V
C60A240V, 480V
C100A240V, 480V
D150A240V, 480V, 600V
D200A240V, 480V, 600V
E250A240V, 480V, 600V
E300A240V, 480V, 600V
F400A240V, 480V, 600V
F600A240V, 480V, 600V
G800A240V, 480V, 600V
G1200A240V, 480V, 600V
H1600A240V, 480V, 600V

This table is a sample representation of frame sizes, ampere ratings, and voltage ratings for Molded Case Circuit Breakers, not an exhaustive list.

Molded case circuit breakers (MCCBs) and insulated case circuit breakers (ICCBs) are two distinct types of circuit protection devices used in electrical systems. Both serve the purpose of interrupting electrical currents in case of faults or overloads, but they differ in construction, application, and performance characteristics. Need Help Now? Call 800-328-1842.