Molded & Insulated Case Circuit Breakers

Currently shopping by:
  • Amperage: 2500 or 3000
  • Ground Fault: No
Remove Filter
While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

TS253F GE Circuit Breaker 2500 Amp 600 VAC M/O

General Electric TS253F circuit breaker: 2500 amp, 600 volt AC, 3 pole, 2000 amp trip, manually operated (M/O), used tested with report.
SKU: MCCB1081

TPS253F GE Circuit Breaker 2500 Amp 600 VAC W/Shunt

General Electric TPS253F circuit breaker; 2500 amp, 600 volt AC, 3 pole. With shunt trip- 120 to 240 volt AC, manually operated (M/O), used tested with report.
SKU: MCCB1070

TPS253F GE Circuit Breaker 2500 Amp 600 VAC W/Shunt

General Electric TPS253F circuit breaker; 2500 amp, 600 volt AC, 3 pole. With shunt trip- 120 to 240 VAC, manually operated (M/O), used tested with report.
SKU: MCCB1071

TP3030TTRE1CR GE Power Break Breaker 3000 Amp 600 VAC E/O

General Electric TP3030TTRE1CR Power Break; 3000 amp with 3000 amp rating plug. Cat.# TR30B3000 Micro Versa Trip, cat.# TT32LI with shunt trip 120 to 240 VAC with auxiliary switch, control voltage 120 VAC, electrically operated (E/O), 600 volt AC, used tested with report.
SKU: MCCB1103

TPMMF76 GE Power Break Breaker 2500 Amp 600 VAC M/O

General Electric TPMMF76 Power Break Circuit Breaker; 2500 amp, 600 volt AC, 3 pole. With 2000 amp trip, shunt trip- 48 volt DC, auxiliary switch, manually operated (M/O), used tested with report.
SKU: MCCB1136

THPMMF76 GE Power Break Breaker 2500 Amp 600 VAC W/Aux. W/Shunt M/O

General Electric THPMMF76 Power Break Circuit Breaker; 2500 amp, 600 volt AC, 3 pole. With 1200 amp trip, auxiliary switch, shunt trip- 48 volt DC, manually operated (M/O), used tested with report.
SKU: MCCB1154

THPMMF76 GE Power Break Breaker 2500 Amp 600 VAC M/O

General Electric THPMMF76 Power Break Circuit Breaker; 2500 amp, 600 volt AC, 3 pole. With 1200 amp trip, shunt trip- 48 volt D.C., auxiliary switch, manually operated (M/O), used tested with report.
SKU: MCCB1078

THPMMF76 GE Power Break Breaker 2500 Amp 600 VAC M/O

General Electric THPMMF76 Power Break; 2500 amp with 2000 amp trip with shunt trip- 48 volt DC, auxiliary switch, 600 volt AC, manually operated (M/O), used tested with report.
SKU: MCCB1124

THPMMF76 GE Power Break Breaker 2500 Amp 600 Volt AC M/O F/M

General Electric THPMMF76 Power Break Circuit Breaker; 2500 amp, 600 volt AC, 3 pole. With 2000 amp trip unit, shunt trip- 48 volt DC, auxiliary switch, manually operated (M/O), fixed mount (F/M), used tested with report.
SKU: MCCB1426

THPMMF76 GE Power Break Breaker 2500 Amp 600 VAC M/O F/M

General Electric THPMMF76 Power Break Circuit Breaker; 2500 amp, 600 volt AC, 3 pole. With 2000 amp trip unit, shunt trip- 48 volt DC, auxiliary switch, manually operated (M/O), fixed mount (F/M), used tested with report.
SKU: MCCB1425

THPMMF76 GE Power Break Breaker 2500 Amp 600 VAC M/O F/M

General Electric THPMMF76 Power Break Circuit Breaker; 2500 amp, 600 volt AC. 3 pole. With 2000 amp trip unit, shunt trip- 48 volt DC, auxiliary switch, manually operated (M/O), fixed mount (F/M), used tested with report.
SKU: MCCB1423

THPMMF7 GE Power Break Breaker 2500 Amp 600 VAC M/O

General Electric THPMMF7 Power Break Circuit Breaker; 2500 amp, 600 volt AC, 3 pole. With 2000 amp trip, shunt trip- 48 volt DC, auxiliary switch, manually operated (M/O), used tested with report.
SKU: MCCB1130

THPMMF7 GE Power Break Breaker 2500 Amp 600 VAC M/O

General Electric THPMMF7 Power Break Circuit Breaker; 2500 amp, 600 volt AC, 3 pole. With 2000 amp trip, shunt trip- 48 VDC, auxiliary switch, manually operated (M/O), used tested with report
SKU: MCCB1129

SSD30D330 GE Power Break II Circuit Breaker 3000 Amp 600 VAC E/O D/O

General Electric SSD30D330 Power Break II circuit breaker; 3000 amp, Entelliguard TU trip unit, cat.# GB530L3XXXRXXXX with auxiliary switch- 240 VAC- 125/250 VDC, shunt trip- 24 VAC, 50/60Hz. 24 VDC. Cat.# SPST024, 600 VAC, electrically operated (E/O), 120 VAC, 50/60 Hz. cat.# SPE120, remote close, 120 VAC, 50/60Hz. cat.# SPRC120, draw-out (D/O), used tested with report *Missing trip cover & upper hinge broken off*.
SKU: MCCB1519

SSD30D330 GE Power Break II Circuit Breaker 3000 Amp 600 VAC E/O D/O

General Electric SSD30D330 Power Break II circuit breaker; 3000 amp, Entelliguard TU trip unit, cat.# GB530L3XXXRXXXX with auxiliary switch, 240 VAC, 125/250 VDC with shunt trip 24 VAC, 50/60Hz. 24 VDC. Cat.# SPST024 600 VAC electrically operated (E/O), 120 VAC, 50/60 Hz. cat.# SPE120, remote close, 120 VAC, 50/60Hz. cat.# SPRC120, draw-out (D/O), used tested with report.
SKU: MCCB1521

SSD30D330 GE Power Break II Circuit Breaker 3000 Amp 600 VAC E/O D/O

General Electric SSD30D330 Power Break II circuit breaker; 3000 amp Entelliguard TU trip unit, cat.# GB530L3XXXRXXXX with 3000 amp rating plug. Cat.# GTP3000U3064 with auxiliary switch 240 VAC, 125/250 VDC, 600 VAC, electrically operated (E/O), 120 VAC, 50/60 Hz. cat.# SPE120 remote close, 120 VAC, 50/60Hz. cat.# SPRC120 draw-out (D/O), used tested with report. *Missing Trip Cover* *Electrically Operated Switch Broken*
SKU: MCCB1523

SCB2500 Westinghouse Breaker 2500 Amp 600 VAC Non-Auto M/O F/M

Westinghouse SCB2500 circuit breaker; non-auto, 2500 amp, 600 volt AC, 3 pole. With shunt trip- 120 VAC, 60 HZ, manually operated (M/O), fixed mount (F/M), used tested with report.
SKU: MCCB1459

SED363000LSES504 Square D Breaker 3000 Amp 600 VAC E/O D/O

Square D SED363000LSES504 breaker; series 3A, 3000 amp with 3000 amp rating plug cat.#RP100 with shunt trip 24 VDC, shunt close, 120 VAC, 50/60 HZ with alarm switches, 120/240 VAC, 50/60 HZ with 4 auxiliary switches 125 VDC, 120 VAC, 50/60 HZ, 600 VAC, electrically operated (E/O), spring charging motor, 120 VAC, 50/60 HZ spring charge contact 125-250 VAC, 50/60 HZ, draw-out (D/O), used tested with report.
SKU: MCCB1272

SEF362500LS Square D Breaker 2500A 3P 600 VAC M/O F/M

Square D SEF362500LS breaker S3B, type SEF, 2500 amp, three pole, 600 VAC Micro logic, series B trip unit with LSI functions, manually operated (M/O), fixed mount (F/M), used with test report.
SKU: MCCB1816

TPMMF768 GE Power Break 2500 Amp 600 VAC

General Electric TPMMF768 Power Break Circuit Breaker; 2500 amp, 600 volt AC, 3 pole. With 2000 amp trip, manually operated (MO), used tested with report.
SKU: MCCB1079

New, Used, and Tested Molded & Insulated Case Circuit Breakers

EMSCO has been specializing in used and refurbished molded & insulated case circuit breakers for over 72 years.


Why Choose EMSCO for Molded Case or Insulated Case Circuit Breakers?

Want to match and replace your existing breakers? End the hassle of retrofitting your electrical system. Our extensive inventory includes a variety of Molded Case Circuit Breakers (MCCBs) and Insulated Case Circuit Breakers that are designed to seamlessly match and replace your existing breakers by brand, amp rating, voltage, frame size, or model.

New and Refurbished Products in Stock

We understand that budgets and preferences differ, so we give you the option of selecting between new and refurbished MCCBs or Insulated Case Breakers, both of which are readily available in our inventory. Choose brand-new circuit breakers for maximum performance and longevity, or look into our refurbished options, which have been rigorously tested and reconditioned to meet industry standards.

Popular Brands and Common Configurations

Our shelves are stocked with breakers from the most trusted and popular brands in the industry, ensuring you have access to dependable products. You'll find common configurations, such as different frame sizes and voltage ratings, making it simple to find the right circuit protection for your application.

Avoiding Costly Operational Downtime

Downtime can be an expensive situation. Our circuit protection products are designed for high performance and durability. You can avoid costly operational downtime due to electrical failures by using our fully-tested Molded Case or Insulated Case breakers. Our products provide reliable power and superior equipment protection.

Electrical Testing Equipment Certifying Quality and Performance

When it comes to the dependability and safety of your electrical systems, we leave nothing to chance. Our breakers are rigorously tested using current testing equipment to ensure that they meet or exceed industry standards. This ensures that your electrical installations are safe and efficient.

  • Overcurrent Protection: We verify that your breakers provide accurate overcurrent protection, guaranteeing the safety of your electrical systems.
  • Trip Time: We measure the time it takes for breakers to respond to overcurrent conditions, ensuring it operates within the specified trip time.
  • Short-Circuit Withstand Capacity: Our testing evaluates the breaker’s ability to withstand short-circuit currents, preventing damage and maintaining safety.
  • Interrupting Capacity: We determine the MCCB's capability to interrupt fault currents, ensuring the utmost protection for your electrical system.

Molded Case Circuit Breaker Specifications

A sample table of ampere ratings, corresponding voltage ratings, and frame sizes for molded case circuit breakers is shown below. Please keep in mind that frame sizes and ratings can differ between manufacturers and models. For precise details on a specific MCCB, always refer to the manufacturer's specifications.

Frame Size

Ampere Rating

Voltage Rating

A

15A

120V, 240V

A

20A

120V, 240V

B

30A

120V, 240V, 480V

B50A120V, 240V, 480V
C60A240V, 480V
C100A240V, 480V
D150A240V, 480V, 600V
D200A240V, 480V, 600V
E250A240V, 480V, 600V
E300A240V, 480V, 600V
F400A240V, 480V, 600V
F600A240V, 480V, 600V
G800A240V, 480V, 600V
G1200A240V, 480V, 600V
H1600A240V, 480V, 600V

This table is a sample representation of frame sizes, ampere ratings, and voltage ratings for Molded Case Circuit Breakers, not an exhaustive list.

Molded case circuit breakers (MCCBs) and insulated case circuit breakers (ICCBs) are two distinct types of circuit protection devices used in electrical systems. Both serve the purpose of interrupting electrical currents in case of faults or overloads, but they differ in construction, application, and performance characteristics. Need Help Now? Call 800-328-1842.