Molded & Insulated Case Circuit Breakers

Currently shopping by:
  • Voltage: 480
Remove Filter
While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

ED43B025 ITE & Siemens Circuit Breaker

ITE & Siemens ED43B025 circuit breaker: 25 amp, 480 volt, three pole, line & load side lugs. Used tested with report.
SKU: ED43B025

GHB3015 Cutler-Hammer Circuit Breaker

Cutler-Hammer GHB3015 circuit breaker: 15 amp, 480 volt, three pole, load side lug. Used tested with report.
SKU: GHB3015

THED134125 General Electric Circuit Breaker

General Electric THED134125 circuit breaker; 125 amp, 480 volt, three pole, line & load side lugs. Used tested with report.
SKU: THED134125

THED134100 General Electric Circuit Breaker

General Electric THED134100 circuit breaker; 100 amp, 480 volt, three pole, line & load side lugs. Used tested with report.
SKU: THED134100

THED134080 General Electric Circuit Breaker

General Electric THED134080 circuit breaker; 80 amp, 480 volt, three pole, line & load side lugs. Used tested with report.
SKU: THED134080

General Electric THED134070 Circuit Breaker

General Electric THED134070 molded case circuit breaker; 70 amp, 480 volt, three pole, line & load side lugs. Used tested with report.
SKU: THED134070

THED134150 General Electric Circuit Breaker

General Electric THED134150 circuit breaker; 150 amp, 480 volt, three pole, line & load side lugs. Used tested with report.
SKU: THED134150

THED134090 General Electric Circuit Breaker

General Electric THED134090 circuit breaker; 90 amp, 480 volt, three pole, line & load side lugs. Used tested with report.
SKU: THED134090

THED134015 General Electric Circuit Breaker

General Electric THED134015 circuit breaker; 15 amp, 480 volt, three pole, line & load side lugs. Used tested with report.
SKU: THED134015

THED134020 General Electric Circuit Breaker

General Electric THED134020 circuit breaker; 20 amp, 480 volt, three pole, line & load side lugs. Used tested with report.
SKU: THED134020

THED134030 General Electric Molded Case Circuit Breaker

General Electric THED134030 circuit breaker; 30 amp, 480 volt, three pole, line & load side lugs. Used tested with report.
SKU: THED134030

THED134050 General Electric Circuit Breaker

General Electric THED134050 circuit breaker; 50 amp, 480 volt, three pole, line & load side lugs. Used tested with report.
SKU: THED134050

THED134060 General Electric Circuit Breaker

General Electric THED134060 circuit breaker; 60 amp, 480 volt, three pole, line & load side lugs. Used tested with report.
SKU: THED134060

THPMM5616 GE Power Break Breaker 1600 Amp 480 VAC M/O

General Electric THPMM5616 Power Break Circuit Breaker; 1600 amp, 480 volt AC, 3 pole. With auxiliary switch, manually operated (M/O), used tested with report.
SKU: MCCB1060

THPMM5616 GE Power Break Breaker 1600 Amp 480 VAC W/Aux. W/Shunt M/O

General Electric THPMM5616 Power Break Circuit Breaker; 1600 amp, 480 volt AC, 3 pole. With auxiliary switch, shunt trip- 48 volt DC, manually operated (M/O), used tested with report.
SKU: MCCB1062

THPMM5616 GE Power Break Breaker 1600 Amp 480 VAC W/Aux. W/Shunt

General Electric THPMM5616 Power Break Circuit Breaker; 1600 amp, 480 Volt AC, 3 pole. With auxiliary switch, shunt trip- 48 Volt DC, manually operated (M/O), used tested with report.
SKU: MCCB1063

THPMM5616 GE Power Break Breaker 1600 Amp 480 VAC W/Aux. W/Shunt M/O

General Electric THPMM5616 Power Break circuit breaker; 1600 amp, 480 Volt AC, 3 pole. With auxiliary switch, shunt trip- 48 Volt DC, manually operated (M/O), used tested with report.
SKU: MCCB1061

TED134150 General Electric Circuit Breaker

General Electric TED134150 circuit breaker; 150 amp, 480 volt, three pole, line & load side lugs. Used tested with report.
SKU: TED134150

TED134100 General Electric Circuit Breaker

General Electric TED134100 circuit breaker; 100 amp, 480 volt, three pole, line & load side lugs. Used tested with report.
SKU: TED134100

TED134090 General Electric Circuit Breaker

General Electric TED134090 circuit breaker; 90 amp, 480 volt, three pole, line & load side lugs. Used tested with report.
SKU: TED134090

New, Used, and Tested Molded & Insulated Case Circuit Breakers

EMSCO has been specializing in used and refurbished molded & insulated case circuit breakers for over 72 years.


Why Choose EMSCO for Molded Case or Insulated Case Circuit Breakers?

Want to match and replace your existing breakers? End the hassle of retrofitting your electrical system. Our extensive inventory includes a variety of Molded Case Circuit Breakers (MCCBs) and Insulated Case Circuit Breakers that are designed to seamlessly match and replace your existing breakers by brand, amp rating, voltage, frame size, or model.

New and Refurbished Products in Stock

We understand that budgets and preferences differ, so we give you the option of selecting between new and refurbished MCCBs or Insulated Case Breakers, both of which are readily available in our inventory. Choose brand-new circuit breakers for maximum performance and longevity, or look into our refurbished options, which have been rigorously tested and reconditioned to meet industry standards.

Popular Brands and Common Configurations

Our shelves are stocked with breakers from the most trusted and popular brands in the industry, ensuring you have access to dependable products. You'll find common configurations, such as different frame sizes and voltage ratings, making it simple to find the right circuit protection for your application.

Avoiding Costly Operational Downtime

Downtime can be an expensive situation. Our circuit protection products are designed for high performance and durability. You can avoid costly operational downtime due to electrical failures by using our fully-tested Molded Case or Insulated Case breakers. Our products provide reliable power and superior equipment protection.

Electrical Testing Equipment Certifying Quality and Performance

When it comes to the dependability and safety of your electrical systems, we leave nothing to chance. Our breakers are rigorously tested using current testing equipment to ensure that they meet or exceed industry standards. This ensures that your electrical installations are safe and efficient.

  • Overcurrent Protection: We verify that your breakers provide accurate overcurrent protection, guaranteeing the safety of your electrical systems.
  • Trip Time: We measure the time it takes for breakers to respond to overcurrent conditions, ensuring it operates within the specified trip time.
  • Short-Circuit Withstand Capacity: Our testing evaluates the breaker’s ability to withstand short-circuit currents, preventing damage and maintaining safety.
  • Interrupting Capacity: We determine the MCCB's capability to interrupt fault currents, ensuring the utmost protection for your electrical system.

Molded Case Circuit Breaker Specifications

A sample table of ampere ratings, corresponding voltage ratings, and frame sizes for molded case circuit breakers is shown below. Please keep in mind that frame sizes and ratings can differ between manufacturers and models. For precise details on a specific MCCB, always refer to the manufacturer's specifications.

Frame Size

Ampere Rating

Voltage Rating

A

15A

120V, 240V

A

20A

120V, 240V

B

30A

120V, 240V, 480V

B50A120V, 240V, 480V
C60A240V, 480V
C100A240V, 480V
D150A240V, 480V, 600V
D200A240V, 480V, 600V
E250A240V, 480V, 600V
E300A240V, 480V, 600V
F400A240V, 480V, 600V
F600A240V, 480V, 600V
G800A240V, 480V, 600V
G1200A240V, 480V, 600V
H1600A240V, 480V, 600V

This table is a sample representation of frame sizes, ampere ratings, and voltage ratings for Molded Case Circuit Breakers, not an exhaustive list.

Molded case circuit breakers (MCCBs) and insulated case circuit breakers (ICCBs) are two distinct types of circuit protection devices used in electrical systems. Both serve the purpose of interrupting electrical currents in case of faults or overloads, but they differ in construction, application, and performance characteristics. Need Help Now? Call 800-328-1842.