Molded & Insulated Case Circuit Breakers

Currently shopping by:
  • Frame: TC or WLF
Remove Filter
While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

WLF2A320 Siemens 2000A Frame 600V Fused Power CB M/O D/O in Cell

Siemens low voltage AC integrally fused WLF2A320 power circuit breaker; 2000 amp frame, 600 volt, 2000 amp rating plug. Integrated cubicle bus trip unit ETU745, LSIG functions, manually operated (M/O), draw out (D/O), open fuse lock-out WLOFLO, 3000 amp fuses - (A4BY3000-SEA-3) in-cell - WLFG2320, used tested with report.
SKU: AB201421217

WLF3A340 Siemens 4000A Frame 4000A Rated 600V Power Circuit Breaker M/O D/O

Siemens low voltage AC integrally fused WLF3A340 power circuit breaker: 4000 amp frame, 600 volt, 4000 amp rating plug. Integrated cubicle bus trip unit ETU745, LSIG functions, manually operated (M/O), draw out (D/O) in cell - WLFG2340, used tested with report.
SKU: AB201421211

WLF3A340 Siemens 4000A Frame 4000A Rated 600V Power Circuit Breaker M/O D/O

Siemens low voltage AC Integrally fused WLF3A340 power circuit breaker; 4000 amp frame, 600 volt, 4000 amp rating plug. Integrated cubicle bus trip unit ETU745, LSIG functions, manually operated (M/O), draw out (D/O) In cell - WLFG2340, used tested with report.
SKU: AB201421212

WLF3A340 Siemens 4000A Frame 4000A Rated 600V Power Circuit Breaker M/O D/O

Siemens low voltage AC Integrally fused WLF3A340 power circuit breaker: 4000 amp frame, 600 volt, 4000 amp rating plug. Integrated cubicle bus trip unit ETU745, LSIG functions, manually operated (M/O), draw out (D/O) in cell - WLFG2340, used tested with report.
SKU: AB201421213

WLFCAR50 Siemens Fuse Truck for WLF3A3xx or WLF353xx 5000A Frame Size 600V

Siemens WLFCAR50 low voltage AC fuse draw-out: 5000 amp frame, size 600 volt for use with WLF3A3xx circuit breaker or WLF353xx non-autom. Switch fuse replacement kit: WLCLFUSE2003 draw out 6000 amp fuses - (A4BY6000-SEA-1) in cell - WLGF3340 (FB), used tested with report.
SKU: AB201420527

WLFCAR50 Siemens Fuse Truck for WLF3A3xx or WLF353xx 5000A Frame Size 600V in Cell

Siemens WLFCAR50 low voltage AC fuse, draw-out; 5000 amp frame size, 600 volt for use with WLF3A3xx circuit breaker or WLF353xx non-autom. Switch fuse replacement kit: WLCLFUSE2003, draw-out, 6000 amp fuses - (A4BY6000-SEA-1) in cell - WLGF3340 (FB), used electrically OK.
SKU: AB201421210

WLF2A320 Siemens 2000A Frame 2000A Rated 600V Fused Power Circuit Breaker M/O D/O

Siemens low voltage AC integrally fused WLF2A320 power circuit breaker; 2000 amp frame, 600 volt, 2000 amp rating plug. Integrated cubicle bus trip unit ETU745, LSIG functions, manually operated (M/O), draw out (D/O), open fuse, lock-out, WLOFLO 3000 amp fuses - (A4BY3000-SEA-3) in-cell - WLFG2320, used tested with report.
SKU: AB201421216

WLF2A320 Siemens 2000A Frame 2000A Rated 600V Fused Power Circuit Breaker M/O D/O

Siemens low voltage AC integrally fused WLF2A320 power circuit breaker: 2000 amp frame, 600 volt, 2000 amp rating plug. Integrated cubicle bus trip unit ETU745, LSIG functions, manually operated (M/O), draw out (D/O), open fuse lock-out, WLOFLO 3000 amp fuses - (A4BY3000-SEA-3) in-cell - WLFG2320, used tested with report.
SKU: AB201421215

WLF2A320 Siemens 2000A Frame 2000A Rated 600V Fused Power Circuit Breaker M/O D/O

Siemens low voltage AC integrally fused WLF2A320 power circuit breaker: 2000 amp frame, 600 volt, 2000 amp rating plug. Integrated cubicle bus trip unit ETU745, LSIG functions, manually operated (M/O), draw out (D/O), open fuse lock-out, WLOFLO 3000 amp fuses - (A4BY3000-SEA-3) in cell - WLFG2320, used tested with report.
SKU: AB201420526

WLF2A320 Siemens 2000A Frame 2000A Rated 600V Fused Power Circuit Breaker M/O D/O

Siemens low voltage AC integrally fused WLF2A320 power circuit breaker: 2000 amp frame, 600 volt, 2000 amp rating plug. Integrated cubicle bus trip unit ETU745, LSIG functions, manually operated (M/O), draw out (D/O), open fuse lock-out, WLOFLO 3000 amp fuses - (A4BY3000-SEA-3) in cell - WLFG2320, used tested with report.
SKU: AB201420525

WLF2A320 Siemens 2000A Frame 2000A Rated 600V Fused Power Circuit Breaker M/O D/O

Siemens low voltage AC integrally fused WLF2A320 power circuit breaker: 2000 amp frame, 600 volt, 2000 amp rating plug. Integrated cubicle bus trip unit ETU745, LSIG functions, manually operated (M/O), draw out (D/O), open fuse lock-out, WLOFLO 3000 amp fuses - (A4BY3000-SEA-3) in cell - WLFG2320, used tested with report.
SKU: AB201420524

WLF2A320 Siemens 2000A Frame 2000A Rated 600V Fused Power Circuit Breaker M/O D/O

Siemens low voltage AC integrally fused WLF2A320 power circuit breaker: 2000 amp frame, 600 volt, 2000 amp rating plug. Integrated cubicle bus trip unit ETU745, LSIG functions, manually operated (M/O), draw out (D/O), open fuse, lock-out WLOFLO, 3000 amp fuses - (A4BY3000-SEA-3) in cell - WLFG2320, used tested with report.
SKU: AB201420523

TC88TTHE1R GE Power Break Breaker 800 Amp 600 VAC W/Aux.'s E/O W/Shunt

General Electric TC88TTHE1R Power Break Circuit Breaker; 800 amp, 600 volt AC, 3 pole. With 800 amp rating plug cat.# TR8B800, Micro Versa Trip cat.# C208LSHMR, auxiliary switch, shunt trip- 48 volt D.C., electrically operated (E/O), control voltage- 120 volt AC, draw-out (D/O), used tested with report.
SKU: MCCB1019

TC88TTCR GE Power Break Breaker 800 Amp 600 VAC M/O D/O

General Electric TC88TTCR Power Break breaker; 800 amp, 600 volt AC, 3 pole. With Micro Versa Trip Plus trip unit cat.# TT20LI, lI functions, 600 amp rating plug. cat.# TR8B600, shunt trip- 120 to 240 volt AC, 4.5 amps, (2) auxiliary switches- 6A @ 240 VAC, 5A @ 125 VDC, 25A @ 250 VDC, remote close. 120 VAC, 3.3 amps, 600 VAC, manually operated (M/O), draw out (D/O), used tested with report.
SKU: MCCB1746

TC3030SSZ GE Power Break Breaker 3000 Amp 600 VAC M/O D/O

General Electric TC3030SSZ Power Break; 3000 amp, 600 volt AC, 3 pole. With Micro Versa Trip, cat.#TS32LSIGT2Z1, LSIG functions, ground fault, manually operated (M/O), draw-out (D/O), used tested with report (missing trip cover).
SKU: MCCB1127

TC2020TTHR GE Power Break Breaker 2000 Amp 600 VAC W/Aux M/O D/O

General Electric TC2020TTHR Power Break; 2000 amp, 600 volt AC, 3 pole. With 2000 amp rating plug. cat.#TR20B2000, Micro Versa Trip cat.#C220LSHMR, auxiliaries, manually operated (M/O), draw-out (D/O), used tested with report.
SKU: MCCB1017

TC2020TTHR GE Power Break 2000 Amp 600 VAC W/Aux M/O D/O

General Electric TC2020TTHR Power Break Circuit Breaker; 2000 amp, 600 volt AC, 3 pole. With 2000 amp rating plug cat.# TR20B2000, Micro Versa Trip PM cat.# C220LSHMR, auxiliaries, manually operated (M/O), draw-out (D/O), used tested with report.
SKU: MCCB1021

TC2020TTHR GE Power Break 2000 Amp 600 VAC W/2000 Amp Plug M/O D/O

General Electric TC2020TTHR Power Break Circuit Breaker; 2000 amp, 600 volt AC, 3 pole. With 2000 amp plug, auxiliaries, rating plug type TR20B, rating plug, cat# TR20B2000, Micro Versa Trip-PM cat.#C220LSHMR, manually operated (M/O), draw-out (D/O), used tested with report.
SKU: MCCB1005

TC2020TTHR GE Power Break Breaker 2000 Amp 600 VAC M/O D/O

General Electric TC2020TTHR Power Break Circuit Breaker; 2000 amp, 600 volt AC, 3 pole. With 2000 amp plug, manually operated (M/O), draw-out (D/O), with auxiliaries, rating plug type TR20B, rating plug cat# TR20B2000, Micro Versa Trip-PM cat.#C220LSHMR, used tested with report.
SKU: MCCB1006

TCL88SS GE Power Break Breaker 800 Amp 600 VAC M/O D/O

General Electric TCL88SS Power Break Circuit Breaker; 800 amp, 600 volt AC, 3 pole. With 600 amp rating plug cat.# TR8S600, Micro Versa Trip RMS-9 cat.#TS20LSIT1, LSI functions, auxiliary switch, shunt trip- 120 to 240 volt AC, draw-out (D/O) carriage substructure cat.# TDOSO8L, manually operated (M/O), used tested with report.
SKU: MCCB1100

New, Used, and Tested Molded & Insulated Case Circuit Breakers

EMSCO has been specializing in used and refurbished molded & insulated case circuit breakers for over 72 years.


Why Choose EMSCO for Molded Case or Insulated Case Circuit Breakers?

Want to match and replace your existing breakers? End the hassle of retrofitting your electrical system. Our extensive inventory includes a variety of Molded Case Circuit Breakers (MCCBs) and Insulated Case Circuit Breakers that are designed to seamlessly match and replace your existing breakers by brand, amp rating, voltage, frame size, or model.

New and Refurbished Products in Stock

We understand that budgets and preferences differ, so we give you the option of selecting between new and refurbished MCCBs or Insulated Case Breakers, both of which are readily available in our inventory. Choose brand-new circuit breakers for maximum performance and longevity, or look into our refurbished options, which have been rigorously tested and reconditioned to meet industry standards.

Popular Brands and Common Configurations

Our shelves are stocked with breakers from the most trusted and popular brands in the industry, ensuring you have access to dependable products. You'll find common configurations, such as different frame sizes and voltage ratings, making it simple to find the right circuit protection for your application.

Avoiding Costly Operational Downtime

Downtime can be an expensive situation. Our circuit protection products are designed for high performance and durability. You can avoid costly operational downtime due to electrical failures by using our fully-tested Molded Case or Insulated Case breakers. Our products provide reliable power and superior equipment protection.

Electrical Testing Equipment Certifying Quality and Performance

When it comes to the dependability and safety of your electrical systems, we leave nothing to chance. Our breakers are rigorously tested using current testing equipment to ensure that they meet or exceed industry standards. This ensures that your electrical installations are safe and efficient.

  • Overcurrent Protection: We verify that your breakers provide accurate overcurrent protection, guaranteeing the safety of your electrical systems.
  • Trip Time: We measure the time it takes for breakers to respond to overcurrent conditions, ensuring it operates within the specified trip time.
  • Short-Circuit Withstand Capacity: Our testing evaluates the breaker’s ability to withstand short-circuit currents, preventing damage and maintaining safety.
  • Interrupting Capacity: We determine the MCCB's capability to interrupt fault currents, ensuring the utmost protection for your electrical system.

Molded Case Circuit Breaker Specifications

A sample table of ampere ratings, corresponding voltage ratings, and frame sizes for molded case circuit breakers is shown below. Please keep in mind that frame sizes and ratings can differ between manufacturers and models. For precise details on a specific MCCB, always refer to the manufacturer's specifications.

Frame Size

Ampere Rating

Voltage Rating

A

15A

120V, 240V

A

20A

120V, 240V

B

30A

120V, 240V, 480V

B50A120V, 240V, 480V
C60A240V, 480V
C100A240V, 480V
D150A240V, 480V, 600V
D200A240V, 480V, 600V
E250A240V, 480V, 600V
E300A240V, 480V, 600V
F400A240V, 480V, 600V
F600A240V, 480V, 600V
G800A240V, 480V, 600V
G1200A240V, 480V, 600V
H1600A240V, 480V, 600V

This table is a sample representation of frame sizes, ampere ratings, and voltage ratings for Molded Case Circuit Breakers, not an exhaustive list.

Molded case circuit breakers (MCCBs) and insulated case circuit breakers (ICCBs) are two distinct types of circuit protection devices used in electrical systems. Both serve the purpose of interrupting electrical currents in case of faults or overloads, but they differ in construction, application, and performance characteristics. Need Help Now? Call 800-328-1842.