Molded & Insulated Case Circuit Breakers

Currently shopping by:
  • Amperage: 1600
Remove Filter
While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

TPVVF5616B GE Power Break Breaker 1600 Amp 600 VAC M/O

General Electric TPVVF5616B Power Break Circuit Breaker; 1600 amp, 600 volt AC, 3 pole. With Micro Versa Trip. cat.#TP4VT20B, LI functions, manually operated (M/O), used tested with report.
SKU: MCCB1142

TPVVF7616B GE Power Break Breaker 1600 Amp 600 VAC

General Electric TPVVF7616B Power Break Circuit Breaker; 1600 amp, 600 volt AC, 3 pole. With MicroVersa trip cat.# TP4VT25B, long time & instantaneous, auxiliary switch, used tested with report.
SKU: MCCB1069

TPVVF7616B GE Power Break Breakers 1600 Amp MicroVersa Trip 600 VAC

General Electric TPVVF7616B Power Break circuit breaker; 1600 amp, 600 volt AC, 3 pole. With MicroVersa trip cat.# TP4VT25B, instantaneous function, auxiliary switch, used tested with report.
SKU: MCCB1043

TPVVF7616FC GE Power Break Breaker 1600 Amp 600 VAC F/M M/O

General Electric TPVVF7616FC Power Break Circuit Breaker; 1600 amp, 600 volt AC, 3 pole. With MicroVersa trip unit cat.#TP4VT25, LI functions, under voltage release- 72 Ma @ 48 VDC,(3) auxiliary switches - 6A @ 240 VAC, 5A @ 125VDC, 25A @ 250VDC, fixed mount (F/M), manually operated (M/O), used tested with report.
SKU: MCCB1729

TPVVF7616FC GE Power Break Breaker 1600 Amp 600 VAC F/M M/O

General Electric TPVVF7616FC Power Break Circuit Breaker; 1600 amp, 600 volt AC, 3 pole. With MicroVersa trip unit cat.#TP4VT25, LI functions, under voltage release- 72 Ma @ 48 VDC, (3) auxiliary switches - 6A @ 240 VAC, 5A @ 125VDC, 25A @ 250 VDC, fixed mount (F/M), manually operated (M/O), used tested with report. ** Center leg Slightly Bent**
SKU: MCCB1730

TPSS6616SG GE Power Break Breaker 1600 Amp 600 VAC VersaTrip

General Electric TPSS6616SG Power Break Circuit Breaker; 1600 amp, 600 volt AC, 3 pole. With VersaTrip solid state, LSIG functions, ground fault, manually operated (M/O), used tested with report.
SKU: MCCB1037

TPSS6616SG GE Power Break Breaker 1600 Amp 600 VAC VersaTrip M/O

General Electric TPSS6616SG Power Break Circuit Breaker; 1600 amp, 600 volt AC, 3 pole. With VersaTrip solid state, LSIG functions, ground fault, manually operated (M/O), used tested with report.
SKU: MCCB1038

TPVF5616 GE Power Break Breaker 1600 Amp 600 VAC

General Electric TPVF5616 Power Break Circuit Breaker; 1600 amp, 600 volt AC, 3 pole. With Micro VersaTrip. cat.# TP4VT20 with instantaneous function, used tested with report.
SKU: MCCB1085

TPV5616 GE Power Break Breaker 1600 Amp 600 VAC M/O F/M

General Electric TPV5616 Power Break Circuit Breaker; 1600 amp, 600 volt AC, 3 pole. With Versa Trip. cat.#TP4VT20, LI functions, manually operated (M/O), fixed mount (F/M), used tested with report.
SKU: MCCB1636

TPSS6616SG GE Power Break Breaker 1600 Amp 600 VAC VersaTrip M/O

General Electric TPSS6616SG Power Break Circuit Breaker; 1600 amp, 600 volt AC, 3 pole. With Versa Trip solid state, LSIG functions, ground fault, manually operated (M/O), used tested with report.
SKU: MCCB1035

TPMM5616 GE Power Break Breaker 1600 amp 600 VAC W/Shunt Trip W/Aux Switch M/O

General Electric TPMM5616 Power Break Circuit Breaker; 1600 amp, 600 volt AC, 3 pole. With shunt trip- 48 volt D.C., auxiliary switch, manually operated (M/O), used tested with report.
SKU: MCCB1009

TPMM5616 GE Power Break Breaker 1600 Amp 600 VAC M/O

General Electric TPMM5616 Power Break Circuit Breaker; 1600 amp, 600 volt AC, 3 pole. With aux. switch, with shunt trip- 48 volt. D.C., manually operated (M/O), used tested with report.
SKU: MCCB1056

TPMM5616 GE Power Break Breaker 1600 Amp 600 VAC M/O

General Electric TPMM5616 Power Break Circuit Breaker; 1600 amp, 600 volt AC, 3 pole. With shunt trip- 48 volt DC, auxiliary switch, manually operated (M/O), used tested with report.
SKU: MCCB1260

TPMM5616 GE Power Break Breaker 1600 Amp 600 VAC M/O

General Electric TPMM5616 Power Break Circuit Breaker; 1600 amp, 600 volt AC, 3 pole. With shunt trip- 48 volt D.C., auxiliary switch, manually operated (M/O), used tested with report.
SKU: MCCB1011

TPMM5616 GE Power Break Breaker 1600 Amp 600 VAC M/O F/M

General Electric TPMM5616 Power Break breaker; 1600 amp, 600 volt AC, 3 pole. With shunt trip- 48 volt AC, auxiliary switch- 240 volt AC, 125/250 volt DC, manually operated (M/O), fixed mount (F/M), used tested with report.
SKU: MCCB1509

TPMM5616 GE Power Break Breaker 1600 Amp 600 VAC M/O F/M

General Electric TPMM5616 Power Break breaker; 1600 amp, 600 volt AC, 3 pole. With shunt trip- 48 volt AC, auxiliary switch- 240 volt AC, 125/250 VDC, manually operated (M/O), fixed mount (F/M), used tested with report.
SKU: MCCB1510

THPMM5616 GE Power Break Breaker 1600 Amp 480 VAC M/O

General Electric THPMM5616 Power Break Circuit Breaker; 1600 amp, 480 volt AC, 3 pole. With auxiliary switch, manually operated (M/O), used tested with report.
SKU: MCCB1060

TPSS5616 GE Power Break Breaker 1600 Amp 600 VAC M/O

General Electric TPSS5616 Power Break; 1600 amp Versa Trip solid state. Mod.#2, cat.#V22234A with LI functions, 600 volt AC, manually operated (M/O), used tested with report.
SKU: MCCB1051

TPSS6616SG GE Power Break Breaker 1600 Amp 600 VAC VersaTrip M/O

General Electric TPSS6616SG Power Break Circuit Breaker; 1600 amp, 600 volt AC, 3 pole. With Versa Trip solid state, LSIG functions, ground fault, manually operated (M/O), used tested with report.
SKU: MCCB1036

TPSS6616G3BFC GE Power Break Breaker 1600 Amp 600 VAC M/O

General Electric TPSS6616G3BFC Power Break Circuit Breaker; 1600 amp, 600 volt AC, 3 pole. With solid state Versa Trip, LIG functions, ground fault, manually operated (M/O), used tested with report.
SKU: MCCB1137

New, Used, and Tested Molded & Insulated Case Circuit Breakers

EMSCO has been specializing in used and refurbished molded & insulated case circuit breakers for over 72 years.


Why Choose EMSCO for Molded Case or Insulated Case Circuit Breakers?

Want to match and replace your existing breakers? End the hassle of retrofitting your electrical system. Our extensive inventory includes a variety of Molded Case Circuit Breakers (MCCBs) and Insulated Case Circuit Breakers that are designed to seamlessly match and replace your existing breakers by brand, amp rating, voltage, frame size, or model.

New and Refurbished Products in Stock

We understand that budgets and preferences differ, so we give you the option of selecting between new and refurbished MCCBs or Insulated Case Breakers, both of which are readily available in our inventory. Choose brand-new circuit breakers for maximum performance and longevity, or look into our refurbished options, which have been rigorously tested and reconditioned to meet industry standards.

Popular Brands and Common Configurations

Our shelves are stocked with breakers from the most trusted and popular brands in the industry, ensuring you have access to dependable products. You'll find common configurations, such as different frame sizes and voltage ratings, making it simple to find the right circuit protection for your application.

Avoiding Costly Operational Downtime

Downtime can be an expensive situation. Our circuit protection products are designed for high performance and durability. You can avoid costly operational downtime due to electrical failures by using our fully-tested Molded Case or Insulated Case breakers. Our products provide reliable power and superior equipment protection.

Electrical Testing Equipment Certifying Quality and Performance

When it comes to the dependability and safety of your electrical systems, we leave nothing to chance. Our breakers are rigorously tested using current testing equipment to ensure that they meet or exceed industry standards. This ensures that your electrical installations are safe and efficient.

  • Overcurrent Protection: We verify that your breakers provide accurate overcurrent protection, guaranteeing the safety of your electrical systems.
  • Trip Time: We measure the time it takes for breakers to respond to overcurrent conditions, ensuring it operates within the specified trip time.
  • Short-Circuit Withstand Capacity: Our testing evaluates the breaker’s ability to withstand short-circuit currents, preventing damage and maintaining safety.
  • Interrupting Capacity: We determine the MCCB's capability to interrupt fault currents, ensuring the utmost protection for your electrical system.

Molded Case Circuit Breaker Specifications

A sample table of ampere ratings, corresponding voltage ratings, and frame sizes for molded case circuit breakers is shown below. Please keep in mind that frame sizes and ratings can differ between manufacturers and models. For precise details on a specific MCCB, always refer to the manufacturer's specifications.

Frame Size

Ampere Rating

Voltage Rating

A

15A

120V, 240V

A

20A

120V, 240V

B

30A

120V, 240V, 480V

B50A120V, 240V, 480V
C60A240V, 480V
C100A240V, 480V
D150A240V, 480V, 600V
D200A240V, 480V, 600V
E250A240V, 480V, 600V
E300A240V, 480V, 600V
F400A240V, 480V, 600V
F600A240V, 480V, 600V
G800A240V, 480V, 600V
G1200A240V, 480V, 600V
H1600A240V, 480V, 600V

This table is a sample representation of frame sizes, ampere ratings, and voltage ratings for Molded Case Circuit Breakers, not an exhaustive list.

Molded case circuit breakers (MCCBs) and insulated case circuit breakers (ICCBs) are two distinct types of circuit protection devices used in electrical systems. Both serve the purpose of interrupting electrical currents in case of faults or overloads, but they differ in construction, application, and performance characteristics. Need Help Now? Call 800-328-1842.