Low Voltage Switchgear

While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

Square D QED Power Style Switchboard 2500A 3ph 4W 480Y/277V Stand Alone 800A Fused Main NEMA 1 R&G

Square D QED Power Style Switchboard; 2500 amp, three phase, four wire, 480Y/277 volt. Stand alone 800 amp fused main, Nema 1. Reconditioned & guaranteed with a one year warranty.
SKU: M343
Contact us for pricing:

Square D QED Power Style Switchboard 2000A Frame Main PHF2036 480Y/277V 3Ph 4W Rated at 1400A w/ Dist. LSIG R&G

Square D QED Power Style Switchboard; 2000 amp frame main cat# PHF2036 with rating plug cat #ARP100, 480Y/277 volt, three phase, four wire, rated at 1400 amp, distribution section, LSIG functions. Reconditioned & guaranteed with a one year warranty.
SKU: M346
Contact us for pricing:

AMP LB368-ST Fusible Main with GF & Breaker Distribution 1200 Amp 480Y/277 Volt 3 Pole 3 Wire NEMA 1 R&G

American Midwest Power LB368-ST Fusible Main; 1200 amp, 480Y/277 volt, three pole, three wire. With ground fault & breaker distribution, Nema 1 indoor. Reconditioned & guaranteed with a one year warranty.
SKU: M349
Contact us for pricing:

GE Spectra Series Switchboard 3000 Amp 480Y/277 Volt Fusible Main W/GF Nema 1 R&G

General Electric THPC3630G3T Spectra Series Switchboard; 3000 amp HPC fusible main with ground fault, 480Y/277 volt AC, three pole, Nema 1 indoor. Reconditioned & guaranteed with a one year warranty. DISTRIBUTION SECTION IS SOLD.
SKU: M352
Contact us for pricing:

Westinghouse Switchboard MLO 2000 Amp 480Y/277 Volt W/ Fusible Dist & FDP Nema 1 R&G

Westinghouse Switchboard; 2000 amp, main lug only, 480Y/277 volt with fusible distribution & FDP, with ground fault, Nema 1 indoor. Reconditioned & guaranteed with a one year warranty.
SKU: M356
Contact us for pricing:

GE THPC3620G3T Switchboard 2000 Amp Main Breaker 480Y/277 VAC W/ Fusible Spectra Dist. Nema 3R R&G

General Electric THPC3620G3T Switchboard; 2000 amp main breaker, 480Y/277 volt AC with ground fault, fusible spectra distribution, Nema 3R outdoor. Reconditioned & guaranteed with a one year warranty.
SKU: M357
Contact us for pricing:

Siemens SB3 Switchboard 1200 Amp CBC-1233-S Fusible Main 480Y/277 Volt W/ Ground Fault NEMA 1 R&G

Siemens SB3 Switchboard; 1200 amp, CBC-1233-S fusible main, 480Y/277 volt with ground fault, Nema 1 indoor. Reconditioned & guaranteed with a one year warranty.
SKU: M359
Contact us for pricing:

Square D Power Style Switchboard 2000 Amp Fusible Main 480Y/277 Volt w/ GF NEMA 1 R&G

Square D Power Style Switchboard; 2000 amp fusible main with ground fault, 480Y/277 volt, 3 phase, 4 wire, NEMA 1 indoor rated. Reconditioned & guaranteed with a one year warranty.
SKU: M385
Contact us for pricing:

Siemens MSB Switchboard 3000 Amp QA-3033-CBC Fusible Main 208Y/120 Volt NEMA 1 R&G

Siemens MSB Switchboard; 3000 amp, QA-3033-CBC fusible main, 208Y/120 volt, NEMA 1 indoor. Reconditioned & guaranteed with a one year warranty
SKU: M386
Contact us for pricing:

Square D Power Style Switchboard 3000 Amp Main Breaker 480Y/277 Volt W/ LIG NEMA 1 R&G

Square D Power Style Switchboard; 3000 amp main breaker, 480Y/277 volt, rating plug cat# ARP083 with LIG functions, Nema 1 indoor. With Power Logic Metering. Reconditioned & guaranteed with a one year warranty.
SKU: M414
Contact us for pricing:

GE Power Break Switchboard 3000 Amp 480Y/277 Volt TP3030TTR Main Panel W/ GF NEMA 3R R&G

General Electric Power Break Switchboard; 3000 amp, 480Y/277 volt, Nema 3R outdoor. TP3030TTR Main Panel with rating plug with ground fault. With empty and metering sections. Reconditioned & guaranteed with a one year warranty.
SKU: M417
Contact us for pricing:

GE Power Break Switchboard 3000 Amp 480Y/277 Volt TP3030TTR Panel W/ GF NEMA 3R R&G

General Electric Power Break Switchboard; 3000 amp, 480Y/277 volt, Nema 3R outdoor. TP3030TTR Main Panel with rating plug with ground fault. With empty and metering sections. Reconditioned & guaranteed with a one year warranty.
SKU: M418
Contact us for pricing:

Square D QED Power Style Switchboard 1600A 3P 480Y/277V w/ 3 RJF36160JK Breakers M/O F/M R&G

Square D QED Power Style Switchboard; 1600 amp, three pole, 480Y/277 volt, with (3) RJF36160JK PowerPact circuit breakers. Manually operated (M/O), fixed- mount (F/M). Reconditioned & guaranteed with a one year warranty.
SKU: M423
Contact us for pricing:

Square D QED Power Style Switchboard 1600A 480Y/277V RJF36160JK Breaker NEMA 1 R&G

Square D QED Power Style Switchboard; 1600 amp, three pole, 480Y/277 volt, with (3) RJF36160JK PowerPact circuit breakers, NEMA 1 indoor rated. Manually operated (M/O), fixed- mount (F/M). Reconditioned & guaranteed with a one year warranty.
SKU: M424
Contact us for pricing:

AMP F-BPS/FDP Switchboard Fusible Main VLB3410-ST Boltswitch 2000 Amp 480Y/277 Volt NEMA 1 R&G

American Midwest Power F-BPS/FDP Switchboard fusible main VLB3410-ST boltswitch; 2000 amp, 480Y/277 volt, ground fault relay, Nema 1 indoor. Reconditioned & guaranteed with a one year warranty.
SKU: M429
Contact us for pricing:

Square D Power Style Switchboard BPO3616 Fusible Main 1600 Amp 240 Volt NEMA 1 R&G

Square D Power Style Switchboard; BPO3616 fusible main, 1600 Amp, 240 volt, Nema 1 indoor. Reconditioned & guaranteed with a one year warranty.
SKU: M433
Contact us for pricing:

Siemens 1600 Amp 480Y/277 Volt 3 Phase 4 Wire QA-1633-CBC Main Fusible Panel NEMA 1 R&G

Siemens QA-1633-CBC Main Fusible Panel: 1600 amp, 480Y/277 volt, three phase, four wire, GFI with ground fault, sensor relay, NEMA 1 indoor. Recondition & guaranteed with a one year warranty.
SKU: M230
Contact us for pricing:

GE Spectra Series Switchboard 2000 Amp 480Y/277 Volt Fusible Main W/ GF & Spectra Breaker Dist. Nema 3R R&G

General Electric THPC23620B Spectra Series Switchboard; 2000 amp high pressure contact switch fusible main with ground fault & spectra breaker distribution, 480Y/277 volt AC, three pole, four-wire, NEMA 3R outdoor. Reconditioned & guaranteed with a one year warranty.
SKU: M455
Contact us for pricing:

Peterson Electric 2000 amp 480Y/277 volt VLB3410-06 Fusible Main W/ GF NEMA 1 R&G

Peterson Electric boltswitch bolted pressure contact switch: 2000 amp, cat# VLB3410-06 fusible main with GFI, 480Y/277 volt AC, 3 pole, 4 wire, ground fault relay cat# GFR-1, NEMA 1 indoor. With (2) L367-X3 boltswitch bolted pressure contact switch- 800 amp, 600 volt, 3 pole, 3 wire. With (1) V7H3606 vacu- break switch: 600 amp, 600 volts max, 3 pole, 3 phase. With (1) V7H3605 vacu-break switch: 400 amp, 600 volts max, 3 poles, 3 phase, series A. Reconditioned & guaranteed with a one year warranty.
SKU: M456
Contact us for pricing:

Square D Power Style Switchboard 2500A Main Breaker 480Y/277V AC W/ LSIG NEMA 3R R&G

Square D Power Style Switchboard: 2500 amp main breaker, 480Y/277 volt AC, three phase, four wire. With LSIG functions, ground fault interrupter, rating plug cat# RP100, NEMA 3R outdoor. With pull section & breaker distribution sections. Reconditioned and guaranteed with a one year warranty.
SKU: M459
Contact us for pricing:

Upgrade Low Voltage Switchgear: New, Refurbished, Obsolete

We don’t just sell Low Voltage Switchgear. We provide tailored solutions by understanding your situation as a trusted partner in identifying what you need. Asking questions like:

What are the Voltage Rating Requirements?

Let’s make sure the switchgear's voltage rating matches the requirements of the electrical system it will be installed in. Low voltage switchgear typically operates at voltages up to 1000V AC or 1500V DC. Beyond this, consider Medium Voltage switchgear.

What is the Maximum Current Rating?

It’s important to know the maximum current that the switchgear can handle safely. This should align with the expected load and short-circuit currents in the system.

Where is the Operating Environment?

Evaluate the environmental conditions where the switchgear will be installed, including temperature, humidity, dust, and corrosive elements. Choose switchgear with appropriate ingress protection (IP) ratings and environmental certifications.

What Type of Protection is Needed?

By knowing this, we can decide whether the application requires protection against overload, short circuit, or both. Select switchgear with built-in protection features such as circuit breakers, fuses, or protective relays as needed.

How Much Space Do You Have:

Consider the physical dimensions and layout of the installation site to ensure the switchgear fits properly and allows for future expansion if necessary.

Which Safety Standards Need to Be Met?

Verifying the switchgear complies with relevant safety standards and certifications such as IEC, ANSI, UL, or other local regulations. This way the equipment meets minimum safety requirements and performance standards.

What About Reliability and Durability?

Look for switchgear from reputable manufacturers known for producing reliable and durable equipment. Consider factors such as component quality, design robustness, and maintenance requirements.

Is Remote Monitoring and Control Needed?

If remote monitoring and control are desired, choose switchgear with compatible communication interfaces (such as Modbus, Profibus, or Ethernet) and software capabilities for seamless integration into the overall control system.

Have You Considered Arc Flash Mitigation?

Evaluate the switchgear's ability to minimize the risk and severity of arc flash incidents through design features such as arc-resistant construction, fast fault-clearing times, and proper equipment labeling.

What About Cost and Total Ownership?

Assess the initial purchase cost along with long-term maintenance, operating costs, and potential energy savings. Consider the total cost of ownership over the switchgear's lifecycle to make an informed investment decision.

 

How Can We Help?

Let us help you choose the right Low Voltage Switchgear Solution with confidence. You have customized low voltage switchgear needs? We'll match voltage levels, load capacity, and fault current ratings, to name a few considerations. Your switchgear has special demands, so our solutions balance upfront costs with long-term value, with each unit undergoing testing to lower your total cost over its lifespan.