Low Voltage Switchgear

While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

Peterson Electric 2000 amp 480Y/277 volt VLB3410-06 Fusible Main W/ GF NEMA 1 R&G

Peterson Electric boltswitch bolted pressure contact switch: 2000 amp, cat# VLB3410-06 fusible main with GFI, 480Y/277 volt AC, 3 pole, 4 wire, ground fault relay cat# GFR-1, NEMA 1 indoor. With (2) L367-X3 boltswitch bolted pressure contact switch- 800 amp, 600 volt, 3 pole, 3 wire. With (1) V7H3606 vacu- break switch: 600 amp, 600 volts max, 3 pole, 3 phase. With (1) V7H3605 vacu-break switch: 400 amp, 600 volts max, 3 poles, 3 phase, series A. Reconditioned & guaranteed with a one year warranty.
SKU: M456
Contact us for pricing:

ITE Switchboard 2500A Pringle Switch Fusible Main 480Y/277V W/GF NEMA 1 R&G

ITE Switchboard: 2500 amp pringle switch fusible main cat# FP-2534, 480Y/277 volt, three phase, four wire, ground fault interrupter, NEMA 1 indoor. Reconditioned & guaranteed with a one year warranty.
SKU: M460
Contact us for pricing:

General Electric AV-Line THPR3416ET1 Switchboard 1600A 480Y/277V W/GF NEMA 1 R&G

General Electric AV-Line THPR3416ET1 Switchboard; 1600 amp high pressure contact switch, 480Y/277 volt AC, three pole, three phase, four wire, ground fault, NEMA 1 indoor. Reconditioned and guaranteed with a 1 year warranty.
SKU: M467
Contact us for pricing:

GE AV-Line Switchboard 3000A 480Y/277V QA-3033-CBC Main-Tie-Main NEMA 1 GFI R&G

GE AV-Line Switchboard Main-Tie-Main; 3000 amp, 480Y/277 volt, three phase, four wire. (2) QA-3033-CBC fusible main switch with ground fault, fusible distribution, Nema 1 indoor rated, reconditioned and guaranteed with a one year warranty. 9 Sections.
SKU: M478
Contact us for pricing:

SQ D Power Style Switchboard BP03620I Fusible 2000 Amp 480 Volt AC NEMA 3R R&G

Square D Power Style Switchboard BP03620I fusible; 2000 amp fusible main, 480 volt AC, three pole, NEMA 3R outdoor. Reconditioned & guaranteed with a one year warranty.
SKU: M472
Contact us for pricing:

Cutler-Hammer Switchboard Fusible Main VL3611 2500A 480V AC NEMA 3R R&G

Cutler-Hammer Switchboard Fusible Main: Cat# VL3611, 2500 amp, 480 volt AC, NEMA 3R outdoor with distribution sections. Reconditioned & guaranteed with a one year warranty.
SKU: M475
Contact us for pricing:

Square D Power Style Switchboard BP03630I Fusible Main 3000A 480V AC W/GFI NEMA 3R R&G

Square D QED Power Style Switchboard BP03630I fusible main: 3000 amp, 480 volt AC. With ground fault interrupter, NEMA 3R outdoor. Reconditioned & guaranteed with a one year warranty.
SKU: M476
Contact us for pricing:

Cutler-Hammer Switchboard Fusible Main VL3611 2500A 480V AC NEMA 1 R&G

Cutler-Hammer switchboard fusible main; boltswitch bolted pressure contact switch cat# VL3611, 2500 amp, 480 volt AC, NEMA 1 indoor with distribution sections. Reconditioned & guaranteed with a one year warranty.
SKU: M490
Contact us for pricing:

Gus Berthhold Electric Co. Switchboard 2500 Amp 480Y/277 Volt 3Ph 4W NEMA 1 R&G

Gus Berthhold Electric Co. Switchboard; 2500 amp boltswitch VLB3411-ST bolted pressure contact switch, 480Y/277 volt, 3 phase, 4 wire, NEMA 1 indoor rated, ground fault, boltswitch fusible distribution. Reconditioned and guaranteed with a one-year warranty.
SKU: M497
Contact us for pricing:

GE Spectra Series Switchboard THPR3608B 800 Amp 480 Volt 3PH 4W NEMA 1 R&G

General Electric Spectra Series Switchboard; 800 amp fusible main high pressure contact switch, cat# THPR3608B, 480 volt AC, three phase, four-wire, NEMA 1 indoor rated, ADS fusible distribution. Reconditioned & guaranteed with a one year warranty.
SKU: M508
Contact us for pricing:

GE Spectra Series Switchboard 3000 Amp 480Y/277 Volt 3PH 4W NEMA 1 R&G

General Electric Spectra Series Switchboard; 3000 fusible main, 480Y/277 volt AC, three phase, four-wire, ground fault, NEMA 1 indoor rated. Reconditioned & guaranteed with a one year warranty.
SKU: M509
Contact us for pricing:

Westinghouse Pow-R-Line Switchboard QA-2533-CBC Fusible Main 2500 Amp 480Y/277 Volt NEMA 1 R&G

Westinghouse Pow-R-Line Switchboard; QA-2533-CBC fusible main, 2500 amp, 480Y/277 volt. With fusible FDP distribution, ground fault, Nema 1 indoor. Reconditioned & guaranteed with a one year warranty.
SKU: M512
Contact us for pricing:

Siemens 3000 Amp Fusible Main Switchboard 480Y/277 Volt 3Ph 4W GFI W/ Distribution NEMA 1 R&G

Siemens fusible switchboard; 3000 amp Pringle switch fusible main, cat# FP3034-B, 480 volt, 3 phase, 4 wire, ground fault, NEMA 1 indoor. With 2000 amp fusible distribution Pringle switch, & 6 total distribution sections. Reconditioned & guaranteed with a one-year warranty.
SKU: M520
Contact us for pricing:

Square D Power-Style Switchboard 3000 Amp Main Lug Only 120/208 Volt 3 Ph 4W NEMA 1 R&G

Square D Power-Style Switchboard; 3000 Amp main lug only, 120/208 volt AC, 3 phase, 4 wire, NEMA 1 indoor rated. With 1600 amp distribution switch & 3 distribution sections. Reconditioned & guaranteed with a one-year warranty.
SKU: M524
Contact us for pricing:

Siemens 3000 Amp CBC-3033-B Fusible Main Switchboard 480Y/277 Volt 3Ph 4W GFI NEMA 1 R&G

Siemens fusible switchboard; 3000 amp Pringle switch fusible main, cat# CBC-3033-B, 480 volt, 3 phase, 4 wire, ground fault, NEMA 1 indoor. With ITE vacu-break switch fusible distribution. Reconditioned & guaranteed with a one-year warranty.
SKU: M537
Contact us for pricing:

Siemens 3000 Amp QA-3033-CBC Fusible Main Switchboard 480Y/277 Volt 3Ph 4W GFI NEMA 1 R&G

Siemens fusible switchboard; 3000 amp Pringle switch fusible main, QA-3033-CBC, 480 volt, 3 phase, 4 wire, ground fault, NEMA 1 indoor. With Pringle switch & ITE vacu-break switch fusible distribution. Reconditioned & guaranteed with a one-year warranty.
SKU: M539
Contact us for pricing:

Siemens 3000 Amp CBC-3033-B Fusible Main Switchboard 480Y/277 Volt 3Ph 4W GFI NEMA 1 R&G

Siemens fusible switchboard; 3000 amp Pringle switch fusible main, cat# CBC-3033-B, 480 volt, 3 phase, 4 wire, ground fault, NEMA 1 indoor. With Pringle mains & ITE vacu-break switch fusible distribution. Reconditioned & guaranteed with a one-year warranty.
SKU: M540
Contact us for pricing:

Siemens 1600 Amp QA-1633 Pringle Main Switchboard 208Y/120 Volt 3 Phase 4 Wire NEMA 1 R&G

Siemens Pringle Main Fusible Switchboard; cat# QA-1633, 1600 amp, 208/120 volt, 3 phase, 4 wire, NEMA 1 indoor. With ITE Vacu-Break switch distribution section. Reconditioned & guaranteed with a one-year warranty.
SKU: M541
Contact us for pricing:

Siemens 1600 Amp QA-1633 Pringle Main Switchboard 208Y/120 Volt 3 Phase 4 Wire NEMA 1 R&G

Siemens Pringle Main Fusible Switchboard; cat# QA-1633, 1600 amp, 208/120 volt, 3 phase, 4 wire, NEMA 1 indoor. With ITE Vacu-Break switch distribution sections. Reconditioned & guaranteed with a one-year warranty.
SKU: M542
Contact us for pricing:

Siemens 3000 Amp QA-3033 Fusible Main Switchboard 208Y/120 Volt 3Ph 4W NEMA 1 R&G

Siemens fusible switchboard; 3000 amp Pringle switch fusible main, QA-3033, 208Y/120 volt, 3 phase, 4 wire, NEMA 1 indoor. With ITE Vacu-Break switch fusible distribution. Reconditioned & guaranteed with a one-year warranty.
SKU: M543
Contact us for pricing:

Upgrade Low Voltage Switchgear: New, Refurbished, Obsolete

We don’t just sell Low Voltage Switchgear. We provide tailored solutions by understanding your situation as a trusted partner in identifying what you need. Asking questions like:

What are the Voltage Rating Requirements?

Let’s make sure the switchgear's voltage rating matches the requirements of the electrical system it will be installed in. Low voltage switchgear typically operates at voltages up to 1000V AC or 1500V DC. Beyond this, consider Medium Voltage switchgear.

What is the Maximum Current Rating?

It’s important to know the maximum current that the switchgear can handle safely. This should align with the expected load and short-circuit currents in the system.

Where is the Operating Environment?

Evaluate the environmental conditions where the switchgear will be installed, including temperature, humidity, dust, and corrosive elements. Choose switchgear with appropriate ingress protection (IP) ratings and environmental certifications.

What Type of Protection is Needed?

By knowing this, we can decide whether the application requires protection against overload, short circuit, or both. Select switchgear with built-in protection features such as circuit breakers, fuses, or protective relays as needed.

How Much Space Do You Have:

Consider the physical dimensions and layout of the installation site to ensure the switchgear fits properly and allows for future expansion if necessary.

Which Safety Standards Need to Be Met?

Verifying the switchgear complies with relevant safety standards and certifications such as IEC, ANSI, UL, or other local regulations. This way the equipment meets minimum safety requirements and performance standards.

What About Reliability and Durability?

Look for switchgear from reputable manufacturers known for producing reliable and durable equipment. Consider factors such as component quality, design robustness, and maintenance requirements.

Is Remote Monitoring and Control Needed?

If remote monitoring and control are desired, choose switchgear with compatible communication interfaces (such as Modbus, Profibus, or Ethernet) and software capabilities for seamless integration into the overall control system.

Have You Considered Arc Flash Mitigation?

Evaluate the switchgear's ability to minimize the risk and severity of arc flash incidents through design features such as arc-resistant construction, fast fault-clearing times, and proper equipment labeling.

What About Cost and Total Ownership?

Assess the initial purchase cost along with long-term maintenance, operating costs, and potential energy savings. Consider the total cost of ownership over the switchgear's lifecycle to make an informed investment decision.

 

How Can We Help?

Let us help you choose the right Low Voltage Switchgear Solution with confidence. You have customized low voltage switchgear needs? We'll match voltage levels, load capacity, and fault current ratings, to name a few considerations. Your switchgear has special demands, so our solutions balance upfront costs with long-term value, with each unit undergoing testing to lower your total cost over its lifespan.