While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

DS-206 W-Hse 800A Frame/800A Sensor MO/DO Air Breaker LIG

Westinghouse DS-206 low voltage AC power circuit breaker; 800 amp frame, 800 amp sensors. Manually operated, draw-out, Amptector I-A Model with LIG functions. Used electrically OK.
SKU: DS206 #19297

DS-206 W-HSE 800A Frame/800A Sensors LIG MO/DO Air Breaker

Westinghouse DS-206 low voltage AC power circuit breaker; 800 amp frame, 800 amp sensors. Manually operated/ draw-out, amptector I-A model with LIG functions. Used electrically OK.
SKU: DS206 #19298

DS206H W-HSE 800A FRAME/ 800A RATING PLUG MO/DO AIR BREAKER LIG

Westinghouse DS206H low voltage AC power circuit breaker; 800 amp frame, 800 amp sensor. Manually operated/ draw-out, Digitrip RMS 610 trip unit S64LIG with LIG function, RP6D08A080 (800 amp rating plug). Sold used as is.
SKU: DS206H #20204

DS206H W-HSE 800A FRAME/800A RATING PLUG MO/DO AIR BREAKER LIG

WESTINGHOUSE DS-206H low voltage AC power circuit breaker; 800 amp frame, 800 amp sensors. Manually operated, draw-out, Digitrip RMS610 trip unit #S64LIG (LIG functions), #RP6D08A080 (800 amp rating plug). Sold used as is.
SKU: DS206H #20608

DS416 Square D 1600A Frame / 800A Sensors MO/DO Air Breaker LIG

Square D DS-416 low voltage AC power circuit breaker; 1600 amp frame, 800 amp sensors. Manually operated, draw-out, Amptector I-A Model with LIG functions, 120 volt AC shunt trip. Used electrically OK.
SKU: DS416 #20595

DS416 Square D 1600A Frame / 800A Sensors MO/DO Air Breaker LIG

Square D DS-416 low voltage AC power circuit breaker; 1600 amp frame, 800 amp sensors. Manually operated, draw-out, Amptector I-A Model with LIG functions, 120 volt AC shunt trip. Used electrically OK.
SKU: DS416 #20596

DS416 SQ D 1600A FRAME/ 1600A SENSORS MO/DO AIR BREAKER 120 VAC S.T. LIG

SQUARE D DS-416 low voltage AC power circuit breaker; 1600 amp frame, 1600 amp sensors. Manually operated, draw-out, S54LIG trip unit with LIG functions #RP6D16A160 (1600 amp rating plug), 120 VAC shunt trip. Used electrically OK.
SKU: DS416 EMSCO #21313

DS-416 WESTINGHOUSE 1600A 600V LIG Air Circuit Breaker MO/DO LIG

Westinghouse DS-416 low voltage power circuit breaker; type DS, 1600 amp frame, 635 volt max. Manually operated, draw-out, Ampector model with LIG functions, 1600 amp CT. Sold used as-is.
SKU: DS416 EMSCO# 21287

DS-416 WESTINGHOUSE 1600A 635V Air Circuit Breaker MO/DO LIG

Westinghouse DS-416 low voltage power circuit breaker; type DS, 1600 amp frame, 635 volt max. Manually operated, draw-out, Ampector model with LIG functions, no nameplate. Sold used as-is.
SKU: DS416 EMSCO# 21288

DS416 Westinghouse 1600A Frame 600V Air Breaker MO/DO

Westinghouse DS-416 low voltage AC power circuit breaker; 1600 amp frame, 600 volt. No trip unit, manually operated, draw-out. Used electrically OK.
SKU: DS-416 #20560

Westinghouse DS-416 1600A Frame MO/DO Air Breaker with 1200A Sensor - LIG Functions

Westinghouse DS-416 low voltage AC power circuit breaker; 1600 amp frame, 1200 amp sensor. Manually operated, draw-out, Digitrip RMS500 trip unit T54CLIG with LIG functions, PD6D12A1200 (1200 amp rating plug).
SKU: DS416 #19256

DS416 WESTINGHOUSE 1600A FRAME/ 1200A SENSORS MO/DO AIR BREAKER LIG

Westinghouse DS-416 low voltage AC power circuit breaker; 1600 amp frame, 1200 amp sensors. Manually operated, draw-out, Ampector I-A Model with LIG functions, no C.T.'s. Used electrically OK.
SKU: DS416 #20251

DS416 WESTINGHOUSE 1600A FRAME/ 1600A SENSORS MO/DO AIR BREAKER LIG

Westinghouse DS-416 low voltage AC power circuit breaker; 1600 amp frame, 1600 amp sensors. Manually operated, draw-out, Ampector model with LIG functions. Used electrically OK.
SKU: DS416 EMSCO #21252

DS-416 Westinghouse 1600A/400A MO/DO Air Breaker LIG

Westinghouse DS-416 low voltage power circuit breaker; 1600 amp, 600 volt, 3 pole. Amptector: L-I-G, 400 amp CT, manually operated, draw-out. Used E-OK.
SKU: DS-416 #21238

DS-416 W-HSE 1600A 600V MO/DO Air Breaker LIG

Westinghouse DS-416 low voltage AC power circuit breaker; 1600 amp, 600 volt, 3 pole. Amptector I: with L-I-G. Manually operated, draw-out. Used electrically OK.
SKU: DS-416 #21245

DS-420 Square D Air Breaker 600V 2000A EO/FM LIG

Square D DS-420 low voltage power circuit breaker; 600 volt, 2000 amp. Electrically operated, fixed mount, 120 AC control volts, Amptector Model with LIG functions. Used electrically OK.
SKU: DS-420-EO-FM-#22967

DSL206 Westinghouse 800A Frame MO/DO Air Breaker LIG

Westinghouse DSL206 low voltage AC integrally fused power circuit breaker; 800 amp frame, 800 amp sensor. Manually operated, draw-out, Ampector I -A Model with LIG functions. Sold Used As Is.
SKU: DSL206 #19258

DSL-206 Westinghouse 800A 600V MO/DO Air Breaker LIG

Westinghouse DSL-206 Low Voltage AC Integrally Fused Power Circuit Breaker; 800 amp, 600 volt, 3 pole. Amptector I: L-I-G, Manually-operated, draw-out. Used Electrically OK.
SKU: DSL-206 #21298

DSL-206 Westinghouse 800A 600V MO/DO Air Breaker LIG

Westinghouse DSL-206 Low Voltage AC Integrally Fused Power Circuit Breaker; 800 amp, 600 volt, 3 pole. Amptector I: L-I-G, Manually-operated, draw-out. Used electrically OK.
SKU: DSL-206 #21303

FPS-25 FPE 800A 600V MO/DO Air Breaker LIG

Federal Pacific FPS-25 low voltage power circuit breaker; 800 amp, 600 volt, 600 amp CT, 3 pole. SS4-trip with L-I-G functions. Manually-operated, draw-out with cell. Used Electrically OK.
SKU: FPS25 EMSCO#21201

Used and Refurbished Air Circuit Breakers

Air Circuit Breakers (ACB’s) use air to extinguish electrical sparks. When a fault occurs, these circuit breakers disrupt the circuit by releasing a burst of compressed air, extinguishing the arc. This isolates the defective section of the system, preventing damage. High-pressure air cools the electrical arc.

Inventory Selection of Air Circuit Breakers to Match and Replace Yours

Our inventory features a wide range of air circuit breaker types to match and replace your existing electrical equipment seamlessly, ensuring compatibility and optimal performance for different applications. Whether you need a specific voltage rating, current capacity, or unique design, we have options that suit your needs.

New and Refurbished Air Circuit Breakers -- It's Your Choice

We offer customers the flexibility to choose between new and refurbished ACB’s. New circuit breakers ensure the latest technology and warranties, while refurbished breakers provide cost-effective solutions without compromising quality, backed by thorough inspections and testing.

Electrical testing equipment Certifies Quality and Performance

Our products undergo rigorous electrical testing using the newest test equipment to guarantee quality, safety, and optimal performance. Each air circuit breaker is thoroughly inspected, ensuring it meets industry standards and specifications.

Specifications Based on Your Power Requirements

To specify the right air circuit breaker, consider power requirements such as voltage, current rating, breaking capacity, and the type of application. In most cases, air circuit breakers are used where there’s high risk of fire or explosion. Air Breakers are typically used for low voltages up to 15KV.

Our expert team can guide you through selecting the most suitable breaker for your specific power needs.

What Type of Air Circuit Breaker Do You Need?

Air Breaker Type

How the Breaker Type Works

Applications

Plain Break Air Breaker

Utilizes a pair of contacts within a chamber filled with air to interrupt the electrical circuit. When the contacts separate, an arc forms and is extinguished by the surrounding air.

Commonly used in low-voltage applications like residential and commercial settings, protecting against overcurrents and short circuits.

Magnetic Blowout Air Breaker

Uses a magnetic field to drive the arc away from the contacts, ensuring quick interruption and extinguishing of the arc. The magnetic force redirects the arc into a chute, effectively extinguishing it.

Often found in industrial and heavy-duty settings due to their capability to handle high fault currents, making them ideal for heavy machinery and large-scale equipment protection.

Air Chute Breaker

Uses a series of parallel plates to create a chute for the arc. When the contacts open, the arc is diverted into the chute, where it is elongated, cooled, and extinguished before being directed toward the exhaust vent.

Commonly applied in medium-voltage power distribution systems, particularly in substations, to protect transformers and other critical power equipment from faults and overloads.

Air Blast Breaker

Relies on a high-pressure air blast to extinguish the arc. The compressed air directed towards the arc causes rapid cooling and interruption, ensuring efficient breaking of the circuit.

Primarily utilized in high-voltage applications like power stations and critical infrastructure such as data centers and hospitals, offering reliable protection against high fault currents and maintaining system integrity.