Air Circuit Breakers

While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

AK-2A-50-1 GE Air Breaker 1600A 600V MO/DO LSIG

General Electric AK-2A-50-1 low voltage power circuit breaker; 1600 amp, 600 volt. Manually operated, draw-out, digitrip RMS/R500, LSIG functions. Sold used electrically OK.
SKU: AK-2A-50-1-MO-DO-LSIG-#22386

AK-2A-50-1 GE Air Breaker 1600A 600V MO/DO LSIG

General Electric AK-2A-50-1 low voltage power circuit breaker; 1600 amp, 600 volt. Manually operated, draw-out, digitrip RMS 500, LSIG functions, sensor rated 1600 amp. Sold used electrically OK.
SKU: AK-2A-50-1-MO-DO-LSIG-#22798

AK-2A-50-1 GE Air Breaker 1600A 600V MO/DO LSIG

General Electric AK-2A-50-1 low voltage power circuit breaker; 1600 amp, 600 volt. Manually operated, draw-out, digitrip RMS/R500, LSIG functions, sensor rated 800 amp. Used electrically OK.
SKU: AK-2A-50-1-MO-DO-LSIG-#22799

AK-2A-75 GE 3000A Frame/3000A Rated EO/DO Air Breaker****PARTS BREAKER****

General Electric AK-2A-75 Low Voltage Power Circuit Breaker; 3000 amp frame, 3000 amp rated, 600 volt. Static trip III RMS-TSIG-TZ **Bad trip unit with LSIG functions, electrically operated, 115 volt AC, closing voltage, draw-out. Used as is **PARTS BREAKER SEE PICTURES**.
SKU: AK-2A-75 #21171

AK-2A-75-1 GE 3000A Frame 600V EO/DO Air Breaker

General Electric AK-2A-75-1 low voltage power circuit breaker; 3000 amp frame CT's = 2000 / 3000 amp, 600 volt. Electrically operated, 230 volt (190-250 volt range), draw-out, Carriere trip unit, LSIG functions. Sold used electrically OK.
SKU: AK-2A-75 EMSCO #20825

AK-3A-50 GE 1600A Frame 1200A Rated 600V EO/DO Air Breaker LSIG

General Electric AK-3A-50 low voltage power circuit breaker; 1600 amp frame, 1200 amp rated, 600 volt. Electrically operated (230 volt AC - 190-250 volt range), draw-out, PS-1 power sensor trip unit with LSIG. Sold used electrically OK.
SKU: AK-3A-50 EMSCO #20777

AK-3A-50 GE 1600A Frame 1200A Rated 600V EO/DO Air Breaker LSIG

General Electric AK-3A-50 low voltage power circuit breaker; 1600 amp frame, 1200 amp rated, 600 volt. Electrically operated (230 volt AC - 190-250 volt Range), draw-out PS-1 power sensor trip unit with LSIG. Sold used electrically OK
SKU: AK-3A-50 EMSCO #20778

AK-3A-50 GE 1600A Frame 1200A Rated 600V EO/DO Air Breaker LSIG

General Electric AK-3A-50 low voltage power circuit breaker; 1600 amp frame, 1200 amp rated, 600 volt. Electrically operated (230 volt AC - 190-250 volt range), draw-out, PS-1 power sensor trip unit with LSIG. Sold used electrically OK.
SKU: AK-3A-50 EMSCO #21443

AK-3A-50 GE 1600A Frame 1200A Rated 600V EO/DO Air Breaker LSIG

General Electric AK-3A-50 low voltage power circuit breaker; 1600 amp frame; 1200 amp rated, 600 volt. Electrically operated (230 volt AC - 190-250 volt range), draw-out, PS-1 power sensor trip unit with LSIG. Sold used electrically OK.
SKU: AK-3A-50 EMSCO #21454

AK-3A-50 GE 1600A Frame 1200A Rated 600V EO/DO Air Breaker LSIG

General Electric AK-3A-50 low voltage power circuit breaker; 1600 amp frame; 1200 amp rated, 600 volt. Electrically operated (230 volt AC - 190-250 volt range) draw-out, PS-1 power sensor trip unit with LSIG. Sold used electrically OK.
SKU: AK-3A-50 EMSCO #21455

AK3A-50 GE 1600A Frame 600A Rated 600V MO/DO Air Breaker LSIG

General Electric AK3A-50 low voltage power circuit breaker; 1600 amp frame, 600 amp rated, 600 volt. Manually operated, draw-out, PS-1 power sensor trip unit with LSIG. Sold used electrically OK.
SKU: AK-3A-50 EMSCO #20780

AK-3A-50 GE 1600A Frame 600A Rated 600V MO/DO Air Breaker LSIG

General Electric AK-3A-50 low voltage power circuit breaker; 1600 amp frame, 600 volt. Manually operated, draw-out, power sensor trip with LSIG. Sold used electrically OK.
SKU: AK-3A-50 EMSCO #21477

AK3A-50 GE 1600A Frame 600A Rated 600V MO/DO Air Breaker LSIG

General Electric AK3A-50 low voltage power circuit breaker; 1600 amp frame, 600 volt. Manually operated, draw-out, power sensor trip with LSIG. Sold used electrically OK.
SKU: AK-3A-50 EMSCO #21478

AK-3A-50 GE Air Breaker 1600A 600V MO/DO LSIG

General Electric AK-3A-50 low voltage power circuit breaker; 1600 amp, 600 volt. Manually Operated, draw-out, power sensor 600 amp trip, LSIG functions. Used electrically OK.
SKU: AK-3A-50-MO-DO-LSIG-#22380

GE AK3A-50 Air Breaker 600V 1600A MO/DO LSIG

General Electric AK3A-50 low voltage power circuit breaker; 600 volt, 1600 amp. Manually operated, draw-out, LSIG functions**Broken Handle. Used electrically OK.
SKU: AK3A-50 Emsco#22692

AK3A-75 GE 3000A Frame 2000A Rated 600V EO/DO Air Breaker LSIG

General Electric AK3A-75 low voltage power circuit breaker; 3000 amp frame, 2000 amp sensors, 600 volt. Electrically operated, 230 volt (190-250V range), draw-out, power sensor trip unit type PS-1 with LSIG. Sold used electrically OK.
SKU: AK-3A-75 EMSCO #20822

AK3A-75 GE Air Breaker 3000A 600V EO/DO LSIG

General Electrics AK3A-75 low voltage power circuit breaker; 600 volt, 3000 amp. Electric operated, draw-out, FB600 ER RMS trip unit, LSIG functions** Dented Trip button. Used electrically OK.
SKU: AK3A-75 Emsco#22693

AKJ-5A-50 GE Air Breaker 1600A 600V MO/DO LSIG

General Electric AKJ-5A-50 low voltage power circuit breaker; 1600 amp, 600 volt. Manually operated, draw-out, AC Pro trip unit, LSIG functions. Used electrically OK.
SKU: AKJ-5A-50-MO-DO-LSIG-#22398

AKR-10D-30S GE Air Breaker 600V 800A MO/DO LSIG

General Electric AKR-10D-30S low voltage power circuit breaker; 600 volt, 800 amp. Manually operated, draw-out, Micro versa trip plus LSIG functions. Used electrically OK.
SKU: AKR-10D-30S-#22928

AKR-10D-50H 1600A 600V MO/DO Air Breaker LSIG

General Electric AKR-10D-50H low voltage power circuit breaker; 1600 amp, 600 volt. Manually-operated, draw-out, RMS9 Trip: L-S-I-G. Used E-OK.
SKU: AKR-10D-50H #22214

Used and Refurbished Air Circuit Breakers

Air Circuit Breakers (ACB’s) use air to extinguish electrical sparks. When a fault occurs, these circuit breakers disrupt the circuit by releasing a burst of compressed air, extinguishing the arc. This isolates the defective section of the system, preventing damage. High-pressure air cools the electrical arc.

Inventory Selection of Air Circuit Breakers to Match and Replace Yours

Our inventory features a wide range of air circuit breaker types to match and replace your existing electrical equipment seamlessly, ensuring compatibility and optimal performance for different applications. Whether you need a specific voltage rating, current capacity, or unique design, we have options that suit your needs.

New and Refurbished Air Circuit Breakers -- It's Your Choice

We offer customers the flexibility to choose between new and refurbished ACB’s. New circuit breakers ensure the latest technology and warranties, while refurbished breakers provide cost-effective solutions without compromising quality, backed by thorough inspections and testing.

Electrical testing equipment Certifies Quality and Performance

Our products undergo rigorous electrical testing using the newest test equipment to guarantee quality, safety, and optimal performance. Each air circuit breaker is thoroughly inspected, ensuring it meets industry standards and specifications.

Specifications Based on Your Power Requirements

To specify the right air circuit breaker, consider power requirements such as voltage, current rating, breaking capacity, and the type of application. In most cases, air circuit breakers are used where there’s high risk of fire or explosion. Air Breakers are typically used for low voltages up to 15KV.

Our expert team can guide you through selecting the most suitable breaker for your specific power needs.

What Type of Air Circuit Breaker Do You Need?

Air Breaker Type

How the Breaker Type Works

Applications

Plain Break Air Breaker

Utilizes a pair of contacts within a chamber filled with air to interrupt the electrical circuit. When the contacts separate, an arc forms and is extinguished by the surrounding air.

Commonly used in low-voltage applications like residential and commercial settings, protecting against overcurrents and short circuits.

Magnetic Blowout Air Breaker

Uses a magnetic field to drive the arc away from the contacts, ensuring quick interruption and extinguishing of the arc. The magnetic force redirects the arc into a chute, effectively extinguishing it.

Often found in industrial and heavy-duty settings due to their capability to handle high fault currents, making them ideal for heavy machinery and large-scale equipment protection.

Air Chute Breaker

Uses a series of parallel plates to create a chute for the arc. When the contacts open, the arc is diverted into the chute, where it is elongated, cooled, and extinguished before being directed toward the exhaust vent.

Commonly applied in medium-voltage power distribution systems, particularly in substations, to protect transformers and other critical power equipment from faults and overloads.

Air Blast Breaker

Relies on a high-pressure air blast to extinguish the arc. The compressed air directed towards the arc causes rapid cooling and interruption, ensuring efficient breaking of the circuit.

Primarily utilized in high-voltage applications like power stations and critical infrastructure such as data centers and hospitals, offering reliable protection against high fault currents and maintaining system integrity.