While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

AK2-50-2 GE 1600A 600V Air Breaker EO/DO W/ CUBICLE

General Electric AK2-50-2 Low Voltage Power Circuit Breaker; 1600 amp frame, 600 volt. Electrically operated, draw-out, closing voltage: 230 volts, Carriere FB600ER RMS trip unit LSIG with cubicle. Used electrically OK.
SKU: AK-2-50-2 EMSCO #21085

AK-2-75 GE 3000A Frame/3000A Rated EO/DO Air Breaker LIG

General Electric AK-2-75 Air Circuit Breaker; 3000 amp frame, 3000 amp rated, 600 volt. Retrofitted with Amptector I-A model LIG with LIG functions, electrically operated, 115 volt AC, closing voltage, draw-out. Used electrically Okay.
SKU: AK-2-75 #21169

AK-2-75 GE 3000A Frame/3000A Rated EO/DO Air Breaker LIG

General Electric AK-2-75 Air Circuit Breaker; 3000 amp frame, 3000 amp rated, 600 volt. Retrofitted with Amptector, I-A model LIG with LIG functions, electrically operated, 115 volt AC, closing voltage, draw-out. Used electrically Okay.
SKU: AK-2-75 #21170

AK-2-75-1 GE 3000A EO/DO Air Breaker

General Electric AK-2-75-1 low voltage power circuit breaker; 3000 amp, 600 volt. Electrically-operated, draw-out, Siemens-Allis LTI trip: L-I. Used E-OK.
SKU: AK-2-75-1 #21804

AK-2-75-1 GE 3000A Frame/2000A Rated EO/FM

General Electric AK-2-75-1 Air Circuit Breaker; 3000 amp frame, 2000 amp rated, 600 volt. EC1-B trip unit, electrically operated, 230 volt AC closing voltage, fixed-mount. Used electrically OK.
SKU: AK-2-75-1 #21809

AK-2-75-3 GE 3000A EO/DO Air Breaker

General Electric AK-2-75-3 low voltage power circuit breaker; 3000 amp, 600 volt. Electrically-operated, 120 volt Ac control, draw-out, EC-1, 3000 amp rated. Used E-OK.
SKU: AK-2-75-3 #22263

AK2A-50S-2 GE Air Breaker 1600A 600V EO/DO LSI

General Electric AK2A-50S-2 low voltage power circuit breaker; 1600 amp, 600 volt. Electrically operated, draw-out, 230 closing volts, EC-1 trip, LSI functions. Used electrically OK.
SKU: AK2A-50S-2-EO-DO-LSI-#21931

AK2A-50S-2 GE Air Breaker 1600A 600V EO/DO LSI

General Electric AK2A-50S-2 low voltage power circuit breaker; 1600 amp, 600 volt. Electrically operated, draw-out, 230 closing volts, EC-1 trip, LSI functions. Used electrically OK.
SKU: AK2A-50S-2-EO-DO-LSI-#21932

AK-2A-75 GE 3000A Frame/3000A Rated EO/DO Air Breaker****PARTS BREAKER****

General Electric AK-2A-75 Low Voltage Power Circuit Breaker; 3000 amp frame, 3000 amp rated, 600 volt. Static trip III RMS-TSIG-TZ **Bad trip unit with LSIG functions, electrically operated, 115 volt AC, closing voltage, draw-out. Used as is **PARTS BREAKER SEE PICTURES**.
SKU: AK-2A-75 #21171

AK-2A-75 GE 3000A Frame/3000A Rated EO/DO Air Breaker

General Electric AK-2A-75 low voltage power circuit breaker; 3000 amp frame, 3000 amp rating plug (RP6A30A300), 600 volt. Retrofitted with Cutler-Hammer digitrip RMS, trip unit (SRV52LSI (B) ) with LSI functions. Electrically operated, 115 volt AC, closing voltage, draw-out. Used electrically Okay.
SKU: AK-2A-75 #21172

AK-2A-75 GE 3000A Frame/3000A Rated EO/DO Air Breaker

General Electric AK-2A-75 low voltage power circuit breaker; 3000 amp frame, 3000 amp rated, 600 volt. Versa trio with LSI functions, electrically operated, 230 volt AC, control draw-out. Used electrically Okay.
SKU: AK-2A-75 #21815

AK-2A-75 GE 3000A Frame/3000A Rated EO/DO Air Breaker

General Electric AK-2A-75 low voltage power circuit breaker; 3000 amp frame, 600 volt. No trip unit, electrically operated, 115 volt AC, closing voltage, operating range 95-125, draw-out. Used electrically Okay.
SKU: AK-2A-75 #22146

AK-2A-75 GE 3000A Frame/3000A Trip Unit 600V EO/DO Air Breaker LSI

General Electric AK-2A-75 low voltage power circuit breaker; 3000 amp frame, 3000 amp trip, 600 volt, SB-12 auxiliary switch. Electrically operated, closing voltage, 230 volt, draw-out, versa-trip with LSI functions. Sold used electrically OK.
SKU: AK-2A-75 EMSCO #21834

AK-2A-75-1 GE 3000A Frame 600V EO/DO Air Breaker

General Electric AK-2A-75-1 low voltage power circuit breaker; 3000 amp frame CT's = 2000 / 3000 amp, 600 volt. Electrically operated, 230 volt (190-250 volt range), draw-out, Carriere trip unit, LSIG functions. Sold used electrically OK.
SKU: AK-2A-75 EMSCO #20825

AK-3A-100 GE 4000A FRAME EO/DO AIR BREAKER POWER SENSOR TRIP LSG

General Electric AK-3A-100 low voltage power circuit breaker; 4000 amp frame. Electrically operated, draw-out, power sensor trip, LSG functions, trip/ closing voltage 120. Used electrically OK.
SKU: AK-3A-100 EMSCO #20827

AK-3A-100 GE 4000A FRAME EO/DO AIR BREAKER POWER SENSOR TRIP LSG

General Electric AK-3A-100 low voltage power circuit breaker; 4000 amp frame. Electrically operated, draw-out, power sensor trip, LSG functions, trip/closing voltage: 120. Used electrically OK.
SKU: AK-3A-100 EMSCO #20828

GE AK-3A-25 600A Frame/90A Rating EO/DO Air Breaker with LI Functions - Used, Electrically OK

General Electric AK-3A-25 low voltage power circuit breaker; 600 amp frame, 600 volt. Electrically operated, draw out 125 volt DC, electrically closing mechanism, 90 amp breaker rating, power sensor, LI functions. Used, electrically OK.
SKU: AK-3A-25 #21463

AK-3A-25 GE 600A Frame 200A Sensors EO/DO Air Breaker Fused

General Electric AK-3A-25 low voltage power circuit breaker; 600 amp frame, 600 volt, 200 amp rated. Electrically operated, 125 volt DC (90-130 volt range), draw-out, power sensor trip unit, type PS-1A with LI functions. Used electrically OK.
SKU: AK-3A-25 #20833

AK3A-25 GE 600A Frame 300A Rated 600V EO/DO Air Breaker

General Electric AK3A-25 low voltage power circuit breaker; 600 amp frame, 300 amp sensors, 600 volt. Electrically operated, 125 volt DC, (90-140 volt DC range), draw-out, 125 volt DC shunt trip, power sensor trip unit type PS-1A with LI functions. Sold used electrically OK.
SKU: AK-3A-25 EMSCO #20845

AK-3A-25 GE 600A Frame 300A Sensors EO/DO Air Breaker Fused LI

General Electric AK-3A-25 low voltage power circuit breaker; 600 amp frame, 600V volt, 300 amp rated. Electrically operated, 125 volt DC (90-130 volt range), draw-out, power sensor trip unit type PS-1A with LI functions.
SKU: AK-3A-25 #20834

Used and Refurbished Air Circuit Breakers

Air Circuit Breakers (ACB’s) use air to extinguish electrical sparks. When a fault occurs, these circuit breakers disrupt the circuit by releasing a burst of compressed air, extinguishing the arc. This isolates the defective section of the system, preventing damage. High-pressure air cools the electrical arc.

Inventory Selection of Air Circuit Breakers to Match and Replace Yours

Our inventory features a wide range of air circuit breaker types to match and replace your existing electrical equipment seamlessly, ensuring compatibility and optimal performance for different applications. Whether you need a specific voltage rating, current capacity, or unique design, we have options that suit your needs.

New and Refurbished Air Circuit Breakers -- It's Your Choice

We offer customers the flexibility to choose between new and refurbished ACB’s. New circuit breakers ensure the latest technology and warranties, while refurbished breakers provide cost-effective solutions without compromising quality, backed by thorough inspections and testing.

Electrical testing equipment Certifies Quality and Performance

Our products undergo rigorous electrical testing using the newest test equipment to guarantee quality, safety, and optimal performance. Each air circuit breaker is thoroughly inspected, ensuring it meets industry standards and specifications.

Specifications Based on Your Power Requirements

To specify the right air circuit breaker, consider power requirements such as voltage, current rating, breaking capacity, and the type of application. In most cases, air circuit breakers are used where there’s high risk of fire or explosion. Air Breakers are typically used for low voltages up to 15KV.

Our expert team can guide you through selecting the most suitable breaker for your specific power needs.

What Type of Air Circuit Breaker Do You Need?

Air Breaker Type

How the Breaker Type Works

Applications

Plain Break Air Breaker

Utilizes a pair of contacts within a chamber filled with air to interrupt the electrical circuit. When the contacts separate, an arc forms and is extinguished by the surrounding air.

Commonly used in low-voltage applications like residential and commercial settings, protecting against overcurrents and short circuits.

Magnetic Blowout Air Breaker

Uses a magnetic field to drive the arc away from the contacts, ensuring quick interruption and extinguishing of the arc. The magnetic force redirects the arc into a chute, effectively extinguishing it.

Often found in industrial and heavy-duty settings due to their capability to handle high fault currents, making them ideal for heavy machinery and large-scale equipment protection.

Air Chute Breaker

Uses a series of parallel plates to create a chute for the arc. When the contacts open, the arc is diverted into the chute, where it is elongated, cooled, and extinguished before being directed toward the exhaust vent.

Commonly applied in medium-voltage power distribution systems, particularly in substations, to protect transformers and other critical power equipment from faults and overloads.

Air Blast Breaker

Relies on a high-pressure air blast to extinguish the arc. The compressed air directed towards the arc causes rapid cooling and interruption, ensuring efficient breaking of the circuit.

Primarily utilized in high-voltage applications like power stations and critical infrastructure such as data centers and hospitals, offering reliable protection against high fault currents and maintaining system integrity.