Air Circuit Breakers

While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

RLF-800 Siemens-Allis 800A 600V Fused Air Circuit Breaker EO/DO LSI

Siemens-Allis RLF-800 Fused Low Voltage AC Power Circuit Breaker; Rated Max. Volts: 600, rated amps: 800, 600 amp fuses. Electrically operated, draw-out, 120 volt AC - Motor - Trip - Close Type TSI(2T) Trip Unit, 600 amp rating plug - PR6A08A060 with LSI functions. Used As-Is.
SKU: RLF800 #21221

RLF-800 Siemens-Allis 800A 600V Fused Air Circuit Breaker EO/DO LSIG

Siemens-Allis RLF-800 Fused Low Voltage AC Power Circuit Breaker; Rated Max. Volts: 600, Rated Amps: 800, 600 amp fuses. Electrically operated, draw-out, 120 volt AC - Motor - Trip - Close Digi-Trip RMS/R 800, 600 amp rating plug - PR6A08A060 with LSIG functions. Used As-Is.
SKU: RLF800 #21224

RLF-800 Siemens-Allis 800A 600V Fused Air Circuit Breaker EO/DO LSIG

Siemens-Allis RLF-800 Fused Low Voltage AC Power Circuit Breaker; Rated Max. Volts: 600, Rated Amps: 800, 600 amp fuses. Electrically operated, draw-out, 120 volt AC - Motor - Trip - Close Digi-Trip RMS/R 800, 600 amp rating plug - PR6A08A060 with LSIG functions. Used As-Is.
SKU: RLF800 #21222

RLF-800 Siemens-Allis 800A 600V Fused Air Circuit Breaker EO/DO LSIG

Siemens Allis Chalmers RLF-800 Fused Low Voltage AC Power Circuit Breaker; Rated Max. Volts: 600, Rated Amps: 800, 600 amp fuses. Electrically operated, draw-out, 120 volt AC - Motor - Trip - Close Digi-Trip RMS/R 800, 600 amp rating plug - PR6A08A060 with LSIG functions. Used As-Is.
SKU: RLF800 #21223

LK08 ABB 800A 600V EO/DO 120VAC LSI Air Circuit Breaker LSI

ABB ASEA LK08 Brown Boveri A.C. Low Voltage Power Circuit Breaker; 800 amp frame, 800 amp sensors, 600 volt AC. Electrically operated/ draw-out, charge: 120 VAC, close: 120 VAC, trip: 120 VAC, Micropower Shield Type MPS-5 with LSI functions. Used Electrically OK.
SKU: LK-08 # 20640

LK16 ITE/BBC 1600A 600V 120VAC EO/DO Power Circuit Breaker LSI

ITE/BBC LK16 Brown Boveri A.C. Low Voltage Power Circuit Breaker; 1600 amp frame, 1600 amp sensors, 600 volt AC. Electrically operated, draw-out, charge: 120 VAC, close: 120 VAC, trip: 120 VAC, Micro-power Shield Type MPS-5 with LSI functions. Used electrically OK.
SKU: LK-16 # 20637

LK20 ITE/BBC 2000A 600V EO/DO Air Breaker LS

ITE/BBC LK20 Low Voltage Power Circuit Breaker; 2000 amp rated, 2000 amp CT, 600 volt. Electrically operated, draw-out, 125 volt DC, control trip: MPS-4 with LS functions. Used Electrically OK.
SKU: LK20 #21397

LK42 ABB/BBC 4200A 600V EO/DO Air Circuit Breaker LSG

ABB/BBC LK42 Brown Boveri A.C. Low Voltage Power Circuit Breaker; 4200 amp frame, 4200 amp sensors, 600 volt AC. Electrically operated, draw-out, charge: 240 VAC, close: 240 VAC, trip: 240 VDC, Micro-power Shield Type MPS-4G with LSG functions. Used electrically OK.
SKU: LK-42 # 21379

RL-4000 Siemens 4000A 600V Air Breaker EO/DO LSG

Siemens Type RL Low Voltage Power Circuit Breaker RL-4000; 4000 amp Frame, 600 volt, 4000 amp current sensors. 2000 amp Grd. Sensors (when used), Static Trip III - RMS-TSG-TZ-C LSG functions. Electrically operated, draw-out, Motor Volts: 120 VAC, Close Volts: 120 VAC, Trip Volts: 120 VAC, Type Q-11 Auxiliary Switch 4000/.5 CT's. Used Electrically OK.
SKU: RL4000 EMSCO# 21351

RL-3200 Siemens-Allis 3200A EO/DO Air Breaker LSIG

Siemens-Allis Low Voltage AC Power Circuit Breaker RL-3200; 3200 amp, 600 volt. Electrically operated, draw-out. Gold Face TSG Trip: L-S-I-G. Used Electrically OK.
SKU: RL-3200 #20873

LKE16 ABB 1600A 600V MO/DO Air Circuit Breaker LSG

ABB LKE16 A.C. low voltage power circuit breaker; 1600 amp frame, 600 volt AC. Electrically operated, draw-out, 120 volt DC trip / close/ charge, micro-power shield type MPS 4G with LSG functions. Used electrically OK.
SKU: LKE-16 EMSCO #21382

MA250C Allis-Chalmers 5KV 1200A EO/DO Air Circuit Breaker

Allis-Chalmers MA250C Power Circuit Breaker; 1200 amp, 5 KV rated, 3 pole, control: 90V - 130V DC. Electrically operated, draw-out. Sold Used As Is.
SKU: MA250C - EMSCO # 19931

MA250C Allis-Chalmers 5KV 1200A EO/DO Air Circuit Breaker

Allis-Chalmers MA250C Power Circuit Breaker; 1200 amp, 5 KV rated, 3 pole, control: 90V - 130V DC. Electrically operated, draw-out. Note: Broken contactor on unit. Sold Used As Is.
SKU: MA250C - EMSCO # 19932

MA-250C-1 Allis-Chalmers 2000A 4760V Ruptair Air Circuit Breaker EO/DO

Allis Chalmers MA-250C-1 Ruptair Power Circuit Breaker; Rated Max. Volts: 4760 rated amps.: 2000 cycles: 60 rated range, K Factor: 1.24 interrupting, time: 5 cycles, used in Type D Switchgear. Electrically operated, draw-out. Used As-Is.
SKU: MA-250C-1 #19575

MA-250C-1 Allis-Chalmers 2000A 4760V Ruptair Air Circuit Breaker EO/DO

Allis Chalmers MA-250C-1 Ruptair Power Circuit Breaker; Rated Max. volts: 4760 rated, amps: 2000, cycles: 60 rated, Range K Factor: 1.24 interrupting, time: 5 cycles, used in Type D Switchgear. Electrically operated, draw-out. Used As-Is.
SKU: MA-250C-1 #19595

MA-250C-1 Allis-Chalmers 2000A 4760V Ruptair Air Circuit Breaker EO/DO

Allis Chalmers MA-250C-1 Ruptair Power Circuit Breaker; Rated Max. Volts: 4760 Rated, Amps: 2000, Cycles: 60, Rated Range K Factor: 1.24 Interrupting, Time: 5 Cycles, used in Type D Switchgear. Electrically operated, draw-out. Used As-Is.
SKU: MA-250C-1 #19596

MA-250C-1 Allis-Chalmers 1200A 4.76KV Air Breaker EO/DO

Allis-Chalmers MA-250C-1 Ruptair Power Circuit Breaker; 1200 amp, 4.76KV. Electrically operated, draw-out. Rated Short Circuit: 29 KA, used for Type D Switchgear. Used electrically OK.
SKU: MA-250C-1-#22752

MA-250C-1 Allis-Chalmers 1200A 4.76KV Air Breaker EO/DO

Allis-Chalmers MA-250C-1 Ruptair Power Circuit Breaker; 1200 amp, 4.76KV. Electrically operated, draw-out, Rated Short Circuit: 29 KA, Used for Type D Switchgear. Used electrically OK.
SKU: MA-250C-1-#22753

MA-250C-1 Allis-Chalmers 1200A 4.76KV Air Breaker EO/DO

Allis-Chalmers MA-250C-1 Ruptair Power Circuit Breaker; 1200 amp, 4.76KV. Electrically operated, draw-out, Rated Short Circuit: 29KA, Used for Type D Switchgear. Used electrically OK.
SKU: MA-250C-1-#22754

MA-250C-1 Allis-Chalmers 2000A 4.76KV Air Breaker EO/DO

Allis-Chalmers MA-250C-1 Ruptair Power Circuit Breaker; 2000 amp, 4.76KV. Electrically operated, draw-out, Rated Short Circuit: 29 KA, used for type D switchgear. Used electrically OK.
SKU: MA-250C-1-#22755

Used and Refurbished Air Circuit Breakers

Air Circuit Breakers (ACB’s) use air to extinguish electrical sparks. When a fault occurs, these circuit breakers disrupt the circuit by releasing a burst of compressed air, extinguishing the arc. This isolates the defective section of the system, preventing damage. High-pressure air cools the electrical arc.

Inventory Selection of Air Circuit Breakers to Match and Replace Yours

Our inventory features a wide range of air circuit breaker types to match and replace your existing electrical equipment seamlessly, ensuring compatibility and optimal performance for different applications. Whether you need a specific voltage rating, current capacity, or unique design, we have options that suit your needs.

New and Refurbished Air Circuit Breakers -- It's Your Choice

We offer customers the flexibility to choose between new and refurbished ACB’s. New circuit breakers ensure the latest technology and warranties, while refurbished breakers provide cost-effective solutions without compromising quality, backed by thorough inspections and testing.

Electrical testing equipment Certifies Quality and Performance

Our products undergo rigorous electrical testing using the newest test equipment to guarantee quality, safety, and optimal performance. Each air circuit breaker is thoroughly inspected, ensuring it meets industry standards and specifications.

Specifications Based on Your Power Requirements

To specify the right air circuit breaker, consider power requirements such as voltage, current rating, breaking capacity, and the type of application. In most cases, air circuit breakers are used where there’s high risk of fire or explosion. Air Breakers are typically used for low voltages up to 15KV.

Our expert team can guide you through selecting the most suitable breaker for your specific power needs.

What Type of Air Circuit Breaker Do You Need?

Air Breaker Type

How the Breaker Type Works

Applications

Plain Break Air Breaker

Utilizes a pair of contacts within a chamber filled with air to interrupt the electrical circuit. When the contacts separate, an arc forms and is extinguished by the surrounding air.

Commonly used in low-voltage applications like residential and commercial settings, protecting against overcurrents and short circuits.

Magnetic Blowout Air Breaker

Uses a magnetic field to drive the arc away from the contacts, ensuring quick interruption and extinguishing of the arc. The magnetic force redirects the arc into a chute, effectively extinguishing it.

Often found in industrial and heavy-duty settings due to their capability to handle high fault currents, making them ideal for heavy machinery and large-scale equipment protection.

Air Chute Breaker

Uses a series of parallel plates to create a chute for the arc. When the contacts open, the arc is diverted into the chute, where it is elongated, cooled, and extinguished before being directed toward the exhaust vent.

Commonly applied in medium-voltage power distribution systems, particularly in substations, to protect transformers and other critical power equipment from faults and overloads.

Air Blast Breaker

Relies on a high-pressure air blast to extinguish the arc. The compressed air directed towards the arc causes rapid cooling and interruption, ensuring efficient breaking of the circuit.

Primarily utilized in high-voltage applications like power stations and critical infrastructure such as data centers and hospitals, offering reliable protection against high fault currents and maintaining system integrity.