Air Circuit Breakers

While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

DST-5-250 Federal Pacific Air Breaker 2000A 4.76KV EO/DO

Federal Pacific DST-5-250 Air Breaker; 2000 amps, 4.76 KV. Electrically operated, draw-out, 125 DC close volts. Used electrically OK.
SKU: DST-5-250-2000A-#22885

DST-5-250 FPE 2000A 5KV AIR CIRCUIT BREAKER EO/DO

Federal Pacific DST-5-250 air circuit breaker; 2000 amp. 5 KV rated. Electrically operated, draw-out, close volt: 125 VDC, trip volt: 125 VDC. Used as is.
SKU: DST-5-250-EMSCO #19588

DST-5-250 FPE 2000A 5KV AIR CIRCUIT BREAKER EO/DO

Federal Pacific DST-5-250 air circuit breaker; 2000 amp. 5 KV rated. Electrically operated, draw-out, close volt: 125 VDC, trip volt: 125 VDC. Used as is.
SKU: DST-5-250-EMSCO #19587

FP-50 FPE 1600A FRAME/1000A RATED CONTIN. CURRENT EO/ST AIR BREAKER LI

Federal Pacific FP-50 low voltage power circuit breaker; 1600 amp frame, 1000 amp rated, Contin. current. Electrically operated, close voltage:115 AC, trip voltage: 115 AC, charge motor: 115 AC, stationary, in cell with LI functions on trip unit. Used electrically OK.
SKU: FP50 EMSCO #20463

FP-75 FPE 3000A Frame/1600A Rated 600V EO/Stationary Air Breaker LI

Federal Pacific FP-75 low voltage power circuit breaker; 3000 amp frame, 1600 amp rated, 600 volt. Electrically operated, Stationary, 115 VAC close voltage, 115 VAC trip voltage, 115 VAC charge motor, TD1 series trip device with LI functions. Used electrically OK.
SKU: FP75 EMSCO #20437

FP-75 FPE 3000A/3000A RATED EO/DO Air Breaker LI

Federal Pacific FP-75 low voltage power circuit breaker; 3000 amp frame, 3000 amp rated Contin. current. Electrically operated, draw-out, close voltage: 115 AC trip voltage: 115 AC, charge motor: 115 AC with LI functions on trip unit. Used electrically OK.
SKU: FP75 EMSCO #20465

LA-1600 Allis-Chalmers 1600A 600V EO/DO Air Circuit Breaker

Allis-Chalmers LA-1600 (Blue Face) Air Circuit Breaker; 1600 amp frame, 600 volt, static trip II with long time. Electrically operated, draw-out, 120 volt AC, 1600/1 CT. Used electrically OK.
SKU: LA1600 EMSCO# 20912

LA-1600 Allis-Chalmers 1600A 600V Air Circuit Breaker EO/DO

Allis-Chalmers LA-1600 (Blue Face) Air Circuit Breaker; 1600 amp frame, 600 volt, static trip III with long time. Electrically operated, draw-out, 120 volt AC, 1600/5 CT. Used Electrically OK.
SKU: LA1600 EMSCO# 21415

LA-3000 Allis Chalmers 3000A 600V Air Breaker EO/DO

Siemens-Allis LA-3000 Type LA (BLUE) Air Circuit Breaker; 3000 amp frame, 600 volt. No trip unit, electrically operated/ draw-out, 120 volt AC/DC, 3000 amp C.T.'s (Multi-tap). Used Electrically OK.
SKU: LA-3000 EMSCO# 21366

LA-3000 Allis Chalmers 3000A 600V Air Breaker EO/DO

Allis Chalmers LA-3000 Type LA (BLUE) Air Circuit Breaker; 3000 amp frame, 600 volt. No trip unit, electrically operated, draw-out, 120 votl AC/DC, 3000 amp C.T.'s (Multi-tap). Used Electrically OK.
SKU: LA-3000 EMSCO# 21367

LA-3200A Allis-Chalmers 3200A 600V Gold Air Breaker EO/DO LI

Allis-Chalmers LA-3200A Type LA (Gold) Low Voltage AC Power Circuit Breaker; 3000 amp frame, 600 volt. Static trip II # TI(2T) with LI functions. Electrically operated, draw-out, 120 volt AC. Used Electrically OK.
SKU: LA-3200A EMSCO# 21759

LA-4000 Allis Chalmers 4000A 600V Air Breaker EO/DO

Allis Chalmers LA-4000 Type LA (BLUE) Air Circuit Breaker; 3200 amp frame, 600 volt. Model A1 trip with Inst. functions. Electrically operated, draw-out, 220 volt AC/DC, 4000 amp C.T.'s (Multi-tap). Used Electrically OK.
SKU: LA-4000 EMSCO #21362

LA-4000 Allis-Chalmers 4000A 600V Air Circuit Breaker Blue EO/DO LS

Allis-Chalmers LA-4000 Type LA (Blue Face) Air Circuit Breaker; 4000 amp frame, 600 volt. Static trip II type TS with LS functions. Electrically operated, draw-out. Used Electrically OK.
SKU: LA4000 EMSCO# 20706

MA250C Allis-Chalmers 5KV 1200A EO/DO Air Circuit Breaker

Allis-Chalmers MA250C Power Circuit Breaker; 1200 amp, 5 KV rated, 3 pole, control: 90V - 130V DC. Electrically operated, draw-out. Sold Used As Is.
SKU: MA250C - EMSCO # 19931

MA250C Allis-Chalmers 5KV 1200A EO/DO Air Circuit Breaker

Allis-Chalmers MA250C Power Circuit Breaker; 1200 amp, 5 KV rated, 3 pole, control: 90V - 130V DC. Electrically operated, draw-out. Note: Broken contactor on unit. Sold Used As Is.
SKU: MA250C - EMSCO # 19932

MA-250C-1 Allis-Chalmers 2000A 4760V Ruptair Air Circuit Breaker EO/DO

Allis Chalmers MA-250C-1 Ruptair Power Circuit Breaker; Rated Max. Volts: 4760 rated amps.: 2000 cycles: 60 rated range, K Factor: 1.24 interrupting, time: 5 cycles, used in Type D Switchgear. Electrically operated, draw-out. Used As-Is.
SKU: MA-250C-1 #19575

MA-250C-1 Allis-Chalmers 2000A 4760V Ruptair Air Circuit Breaker EO/DO

Allis Chalmers MA-250C-1 Ruptair Power Circuit Breaker; Rated Max. volts: 4760 rated, amps: 2000, cycles: 60 rated, Range K Factor: 1.24 interrupting, time: 5 cycles, used in Type D Switchgear. Electrically operated, draw-out. Used As-Is.
SKU: MA-250C-1 #19595

MA-250C-1 Allis-Chalmers 2000A 4760V Ruptair Air Circuit Breaker EO/DO

Allis Chalmers MA-250C-1 Ruptair Power Circuit Breaker; Rated Max. Volts: 4760 Rated, Amps: 2000, Cycles: 60, Rated Range K Factor: 1.24 Interrupting, Time: 5 Cycles, used in Type D Switchgear. Electrically operated, draw-out. Used As-Is.
SKU: MA-250C-1 #19596

MA-250C-1 Allis-Chalmers 1200A 4.76KV Air Breaker EO/DO

Allis-Chalmers MA-250C-1 Ruptair Power Circuit Breaker; 1200 amp, 4.76KV. Electrically operated, draw-out. Rated Short Circuit: 29 KA, used for Type D Switchgear. Used electrically OK.
SKU: MA-250C-1-#22752

MA-250C-1 Allis-Chalmers 1200A 4.76KV Air Breaker EO/DO

Allis-Chalmers MA-250C-1 Ruptair Power Circuit Breaker; 1200 amp, 4.76KV. Electrically operated, draw-out, Rated Short Circuit: 29 KA, Used for Type D Switchgear. Used electrically OK.
SKU: MA-250C-1-#22753

Used and Refurbished Air Circuit Breakers

Air Circuit Breakers (ACB’s) use air to extinguish electrical sparks. When a fault occurs, these circuit breakers disrupt the circuit by releasing a burst of compressed air, extinguishing the arc. This isolates the defective section of the system, preventing damage. High-pressure air cools the electrical arc.

Inventory Selection of Air Circuit Breakers to Match and Replace Yours

Our inventory features a wide range of air circuit breaker types to match and replace your existing electrical equipment seamlessly, ensuring compatibility and optimal performance for different applications. Whether you need a specific voltage rating, current capacity, or unique design, we have options that suit your needs.

New and Refurbished Air Circuit Breakers -- It's Your Choice

We offer customers the flexibility to choose between new and refurbished ACB’s. New circuit breakers ensure the latest technology and warranties, while refurbished breakers provide cost-effective solutions without compromising quality, backed by thorough inspections and testing.

Electrical testing equipment Certifies Quality and Performance

Our products undergo rigorous electrical testing using the newest test equipment to guarantee quality, safety, and optimal performance. Each air circuit breaker is thoroughly inspected, ensuring it meets industry standards and specifications.

Specifications Based on Your Power Requirements

To specify the right air circuit breaker, consider power requirements such as voltage, current rating, breaking capacity, and the type of application. In most cases, air circuit breakers are used where there’s high risk of fire or explosion. Air Breakers are typically used for low voltages up to 15KV.

Our expert team can guide you through selecting the most suitable breaker for your specific power needs.

What Type of Air Circuit Breaker Do You Need?

Air Breaker Type

How the Breaker Type Works

Applications

Plain Break Air Breaker

Utilizes a pair of contacts within a chamber filled with air to interrupt the electrical circuit. When the contacts separate, an arc forms and is extinguished by the surrounding air.

Commonly used in low-voltage applications like residential and commercial settings, protecting against overcurrents and short circuits.

Magnetic Blowout Air Breaker

Uses a magnetic field to drive the arc away from the contacts, ensuring quick interruption and extinguishing of the arc. The magnetic force redirects the arc into a chute, effectively extinguishing it.

Often found in industrial and heavy-duty settings due to their capability to handle high fault currents, making them ideal for heavy machinery and large-scale equipment protection.

Air Chute Breaker

Uses a series of parallel plates to create a chute for the arc. When the contacts open, the arc is diverted into the chute, where it is elongated, cooled, and extinguished before being directed toward the exhaust vent.

Commonly applied in medium-voltage power distribution systems, particularly in substations, to protect transformers and other critical power equipment from faults and overloads.

Air Blast Breaker

Relies on a high-pressure air blast to extinguish the arc. The compressed air directed towards the arc causes rapid cooling and interruption, ensuring efficient breaking of the circuit.

Primarily utilized in high-voltage applications like power stations and critical infrastructure such as data centers and hospitals, offering reliable protection against high fault currents and maintaining system integrity.