Air Circuit Breakers

While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

DS-840 Westinghouse Air Breaker 600V 4000A EO/DO LSI

Westinghouse DS-840 low voltage AC power circuit breaker; 600 volt, 4000 amp. Electrically operated, draw-out, 120 VAC, Amptector II A Model TR with LSI functions. Used electrically OK.
SKU: DS-840-#22991

DS-840 W-HSE 4000A 600V MO/DO Air Breaker LS

Westinghouse DS-840 low voltage AC power circuit breaker; 4000 amp, 600 volt. Manually operated, draw-out, Amptector II: L-S functions. Used electrically OK.
SKU: DS-840

DS-FUSE TRUCK SQ-D 4000A Rated 600 VAC DO Air Breaker

Square D DS-4000 low voltage AC power circuit breaker; DS-Fuse Truck, 4000 amp, 600 volt, draw-out. Used electrically OK.
SKU: DS-FUSE TRUCK #20258

DS-FUSE TRUCK W-HSE 4000A Rated 600 VAC DO Air Breaker

Westinghouse DS-4000 low voltage; Fuse-Truck DS-Truck, 4000 amp rated, draw-out. Used electrically OK.
SKU: DS-FUSE TRUCK #20512

DSII 632 SQUARE D 3200A 635V RMS610 AIR BREAKER EO/DO LS

Square D DSII-632 low voltage AC power circuit breaker; type DSII, 3200A frame, 635 volt max, 3200 amp rating plug: #RP6D32A320, RMS610 trip unit with LS functions (#S63LS). Electrically operated, draw-out, 120 volt AC- shunt trip- spring release-motor circuit. Sold used as is.
SKU: DSII632 EMSCO#20266

DS-II SQUARE D DSII-632 3200A 600V RMS-610 Air Circuit Breaker EO/DO LS

Square D DSII-632 low voltage AC power circuit breaker; type DS-II, 3200 amp frame, 635 volt max, 3200 amp rating plug: RP6D32A320, RMS610 trip unit with LS functions (S63LS). Electrically operated, draw-out, 120 volt AC - shunt - motor - spring. Sold used as-is.
SKU: DSII632 EMSCO# 19962

DSII-632 Square D Air Breaker 600V 3200A EO/DO LS

Square D DSII-632 low voltage AC power circuit breaker; 600 volt, 3200 amp. Electrically operated, draw-out, 120 VAC, Digitrip RMS 610 with LS functions. Used electrically OK.
SKU: DSII-632-#22970

ITE Current Limiting Fuse Element 4000A

ITE Current Limiting Fuse Element; 4000 amp frame, 6000 amp fuses, class L fuses. Sold Used Electrically OK.
SKU: EMSCO #21142

ITE Current Limiting Fuse Element 4000A

ITE Current Limiting Fuse Element; 4000 amp frame, 6000 amp fuses, class L fuses. Sold Used Electrically OK.
SKU: EMSCO #21143

LA-3200A Allis-Chalmers 3200A 600V Gold Air Breaker EO/DO LI

Allis-Chalmers LA-3200A Type LA (Gold) Low Voltage AC Power Circuit Breaker; 3000 amp frame, 600 volt. Static trip II # TI(2T) with LI functions. Electrically operated, draw-out, 120 volt AC. Used Electrically OK.
SKU: LA-3200A EMSCO# 21759

LA-4000 Allis Chalmers 4000A 600V Air Breaker EO/DO

Allis Chalmers LA-4000 Type LA (BLUE) Air Circuit Breaker; 3200 amp frame, 600 volt. Model A1 trip with Inst. functions. Electrically operated, draw-out, 220 volt AC/DC, 4000 amp C.T.'s (Multi-tap). Used Electrically OK.
SKU: LA-4000 EMSCO #21362

LA-4000 Allis-Chalmers 4000A 600V Air Circuit Breaker Blue EO/DO LS

Allis-Chalmers LA-4000 Type LA (Blue Face) Air Circuit Breaker; 4000 amp frame, 600 volt. Static trip II type TS with LS functions. Electrically operated, draw-out. Used Electrically OK.
SKU: LA4000 EMSCO# 20706

LA-4000A Siemens-Allis Air Breaker 4000A 600V EO/DO LSIG

Siemens-Allis LA-4000A Low Voltage AC Power Circuit Breaker; 4000 amp, 600 volt. Electrically operated, draw-out, 120 VAC, Siemens static trip III with LSIG functions. Used electrically OK.
SKU: LA-4000A-EO-DO-LSIG-#22806

RL-4000 Siemens 4000A 600V Air Breaker EO/DO LSG

Siemens RL-4000 Low Voltage Power Circuit Breaker; 4000 amp frame, 600 volt, 4000 amp current sensors, 2000 amp Grd. sensors (when used). Static Trip III - RMS-TSG-TZ-C with LSG functions. Electrically operated, draw-out, motor volts: 120 VAC, close volts: 120 VAC, trip volts: 120 VAC, type Q-11 auxiliary switch, 4000/.5 CT's. Used Electrically OK.
SKU: RL4000 EMSCO# 20529

RL-4000 Siemens 4000A 600V Air Breaker EO/DO LSG

Siemens RL-4000 Low Voltage Power Circuit Breaker; 4000 amp frame, 4000 amp current sensors, 2000 amp Grd. sensors (when used). Static Trip III - RMS-TSG-TZ-C with LSG functions. Electrically operated, draw-out, motor volts: 120 VAC, close volts: 120 VAC, trip volts: 120 VAC, type Q-11 auxiliary switch, 4000/.5 CT's. Used Electrically OK.
SKU: RL4000 EMSCO# 20530

RL-3200 Siemens Air Breaker 3200A 600V MO/DO LSG

Siemens RL-3200 Air Breaker; 3200 amp, 600 volt. Manually operated, draw-out, Siemens Static Trip III with LSG functions. Used electrically OK.
SKU: RL-3200-MO-DO-LSG-#22349

RL-3200 Siemens 3200A 600V Air Breaker MO/DO LSIG

Siemens RL-3200 Low Voltage Power Circuit Breaker; 3200 amp frame, 600 volt. Static Trip III with LSIG functions. Manually operated, draw-out, 3200 amp CT with cell. Used electrically OK.
SKU: RL3200 EMSCO# 21390

RL-3200 Siemens-Allis 3200A 600V Air Breaker MO/DO LSIG

Siemens-Allis RL-3200 Type RL Low Voltage Power Circuit Breaker; 3200 amp frame, 600 volt. Static Trip II TYPE TSG (3T) LSIG functions. Manually operated, draw-out. 3200/1 CT's. Used Electrically OK.
SKU: RL3200 EMSCO# 20532

RL-4000 Siemens 4000A 600V Air Breaker EO/DO LSG

Siemens Type RL Low Voltage Power Circuit Breaker RL-4000; 4000 amp Frame, 600 volt, 4000 amp current sensors. 2000 amp Grd. Sensors (when used), Static Trip III - RMS-TSG-TZ-C LSG functions. Electrically operated, draw-out, Motor Volts: 120 VAC, Close Volts: 120 VAC, Trip Volts: 120 VAC, Type Q-11 Auxiliary Switch 4000/.5 CT's. Used Electrically OK.
SKU: RL4000 EMSCO# 21351

RL-3200 Siemens-Allis 3200A EO/DO Air Breaker LSIG

Siemens-Allis Low Voltage AC Power Circuit Breaker RL-3200; 3200 amp, 600 volt. Electrically operated, draw-out. Gold Face TSG Trip: L-S-I-G. Used Electrically OK.
SKU: RL-3200 #20873

Used and Refurbished Air Circuit Breakers

Air Circuit Breakers (ACB’s) use air to extinguish electrical sparks. When a fault occurs, these circuit breakers disrupt the circuit by releasing a burst of compressed air, extinguishing the arc. This isolates the defective section of the system, preventing damage. High-pressure air cools the electrical arc.

Inventory Selection of Air Circuit Breakers to Match and Replace Yours

Our inventory features a wide range of air circuit breaker types to match and replace your existing electrical equipment seamlessly, ensuring compatibility and optimal performance for different applications. Whether you need a specific voltage rating, current capacity, or unique design, we have options that suit your needs.

New and Refurbished Air Circuit Breakers -- It's Your Choice

We offer customers the flexibility to choose between new and refurbished ACB’s. New circuit breakers ensure the latest technology and warranties, while refurbished breakers provide cost-effective solutions without compromising quality, backed by thorough inspections and testing.

Electrical testing equipment Certifies Quality and Performance

Our products undergo rigorous electrical testing using the newest test equipment to guarantee quality, safety, and optimal performance. Each air circuit breaker is thoroughly inspected, ensuring it meets industry standards and specifications.

Specifications Based on Your Power Requirements

To specify the right air circuit breaker, consider power requirements such as voltage, current rating, breaking capacity, and the type of application. In most cases, air circuit breakers are used where there’s high risk of fire or explosion. Air Breakers are typically used for low voltages up to 15KV.

Our expert team can guide you through selecting the most suitable breaker for your specific power needs.

What Type of Air Circuit Breaker Do You Need?

Air Breaker Type

How the Breaker Type Works

Applications

Plain Break Air Breaker

Utilizes a pair of contacts within a chamber filled with air to interrupt the electrical circuit. When the contacts separate, an arc forms and is extinguished by the surrounding air.

Commonly used in low-voltage applications like residential and commercial settings, protecting against overcurrents and short circuits.

Magnetic Blowout Air Breaker

Uses a magnetic field to drive the arc away from the contacts, ensuring quick interruption and extinguishing of the arc. The magnetic force redirects the arc into a chute, effectively extinguishing it.

Often found in industrial and heavy-duty settings due to their capability to handle high fault currents, making them ideal for heavy machinery and large-scale equipment protection.

Air Chute Breaker

Uses a series of parallel plates to create a chute for the arc. When the contacts open, the arc is diverted into the chute, where it is elongated, cooled, and extinguished before being directed toward the exhaust vent.

Commonly applied in medium-voltage power distribution systems, particularly in substations, to protect transformers and other critical power equipment from faults and overloads.

Air Blast Breaker

Relies on a high-pressure air blast to extinguish the arc. The compressed air directed towards the arc causes rapid cooling and interruption, ensuring efficient breaking of the circuit.

Primarily utilized in high-voltage applications like power stations and critical infrastructure such as data centers and hospitals, offering reliable protection against high fault currents and maintaining system integrity.