Air Circuit Breakers

While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

5HK ITE Air Circuit Breaker 4.76KV 1200A EO/DO

ITE 5HK Power Circuit Breaker; 4.76 KV, 1200 amp. Electrically operated, draw-out, 230-AC charging voltage, 48-DC close voltage. Sold used electrically OK.
SKU: 5HK-#23028

5HK ITE Air Circuit Breaker 4.76KV 2000A EO/DO

ITE 5HK Power Circuit Breaker; 4.76 KV, 2000 amp. Electrically operated, draw-out, 230 AC charge, 48 DC closing volts. Sold used electrically OK.
SKU: 5HK-#22964

5-HK-2000 ITE Air Circuit Breaker - 5KV 2000A EO/DO

ITE Type: 5-HK-2000 Power Circuit Breaker; 4,160 VAC nominal, 4,760 VAC max, 2000 amp. Electrically operated, draw-out, 230 VAC control voltage for Charge, 48 VDC control voltage for close & trip. MFG date 12/76. Sold used electrically OK.
SKU: 5-HK-2000

AM-13.8-500-4 GE Magne-Blast Circuit Breaker 1200A 15KV EO/DO

General Electric AM-13.8-500-4 Magne-Blast circuit breaker; 1200 amp, 15 KV. Electrically operated, draw-out, DC volt range 90-130. Used electrically OK.
SKU: AM-13.8-500-4-EO-DO-#22350

AM-13.8-500-4 GE Magne-Blast Circuit Breaker 1200A 15KV EO/DO

General Electric AM-13.8-500-4 Magne-Blast circuit breaker; 1200 amp, 15 KV. Electrically operated, draw-out, DC volt range 90-130. Used electrically OK.
SKU: AM-13.8-500-4-EO-DO-#22352

AM-13.8-500-7H GE Magne-Blast Air Breaker 1200A 15KV EO/DO

General Electric AM-13.8-500-7H Magne-Blast Air Breaker; 1200 amp, 15 KV. Electrically operated, draw-out, 18 KA rated short circuit connection, diagram 227A1000 P41. Used electrically OK.
SKU: AM-13.8-500-7H-EO-DO-#22338

AM-13.8-500-7H GE Magne-Blast Air Breaker 1200A 15KV EO/DO

General Electric AM-13.8-500-7H Magne-Blast Air Breaker; 1200 amp, 15 KV. Electrically operated, draw-out, connection diagram 227A1000 P41. Used electrically OK.
SKU: AM-13.8-500-7H-EO-DO-#22351

AM-13.8-500-7H GE Magne-Blast Air Breaker 1200A 15KV EO/DO

General Electric AM-13.8-500-7H Magne-Blast Air Breaker; 1200 amp, 15 KV. Electrically operated, draw-out, connection diagram 227A1000 P41. Used electrically OK.
SKU: AM-13.8-500-7H-EO-DO-#22354

AM-13.8-500-7H GE Magne-Blast Air Breaker 15KV 1200A EO/DO

General Electric AM-13.8-500-7H Magne-Blast Air Breaker; 15 KV, 1200 amp. Electrically operated, draw-out, ML-13 mech type, connection diagram 227A1000 P41. Used electrically OK.
SKU: AM-13.8-500-7H-#23006

AM-13.8-500-7H GE Magne-Blast Air Breaker 15KV 1200A EO/DO

General Electric AM-13.8-500-7H Magne-Blast Air Breaker; 15 KV, 1200 amp. Electrically operated, draw-out, ML-13 mech type, connection diagram 227A1000 P41. Used electrically OK.
SKU: AM-13.8-500-7H-#23007

AM-13.8-500H-4 GE Magne-Blast Air Breaker 1200A 15KV EO/DO

General Electric AM-13.8-500H-4 Magne-Blast Circuit Breaker; 1200 amp, 15 KV. Electrically operated, draw-out, DC volt range 90-130. Used electrically OK.
SKU: AM-13.8-500H-4-EO-DO-#22353

AM-2.4/4.16 100/150 GE Magne-Blast Air Breaker 1200A 4.76KV EO/DO

General Electric AM-2.4/4.16 100/150 Magne-Blast Circuit Breaker; 1200 amp, 4.76 KV. Electrically operated, draw-out, model #6351051 AA. Used electrically OK.
SKU: AM-2.4/4.16-100/150-#22355

AM-2.4/4.16 100/150 GE Magne-Blast Air Breaker 1200A 4.76KV EO/DO

General Electric AM-2.4/4.16 100/150 Magne-Blast Circuit Breaker; 1200 amp, 4.76 KV. Electrically operated, draw-out, model #6351051 AA, Used electrically OK.
SKU: AM-2.4/4.16-100/150-#22356

AM-2.4/4.16 100/150 GE Magne-Blast Air Breaker 1200A 4.76KV EO/DO

General Electric AM-2.4/4.16 100/150 Magne-Blast Circuit Breaker; 1200 amp, 4.76 KV. Electrically operated, draw-out, model #6351051 AA. Used electrically OK.
SKU: AM-2.4/4.16-100/150-#22357

AM-2.4/4.16 100/150 GE Magne-Blast Air Breaker 1200A 4.76KV EO/DO

General Electric AM-2.4/4.16 100/150 Magne-Blast Circuit Breaker; 1200 amp, 4.76 KV. Electrically operated, draw-out, model #6351051, Used electrically OK.
SKU: AM-2.4/4.16-100/150-#22358

AM-2.4/4.16 100/150 GE Magne-Blast Air Breaker 1200A 4.76KV EO/DO

General Electric AM-2.4/4.16 100/150 Magne-Blast Circuit Breaker; 1200 amp, 4.76 KV. Electrically operated, draw-out, model #6351051 AA. Used electrically OK.
SKU: AM-2.4/4.16-100/150-#22359

AM-2.4/4.16 100/150 GE Magne-Blast Air Breaker 1200A 4.76KV EO/DO

General Electric AM-2.4/4.16 100/150 Magne-Blast Circuit Breaker; 1200 amp, 4.76 KV. Electrically operated, draw-out, model #6351051 AA. Used electrically OK.
SKU: AM-2.4/4.16-100/150-#22360

AM-2.4/4.16 100/150 GE Magne-Blast Air Breaker 1200A 4.76KV EO/DO

General Electric AM-2.4/4.16 100/150 Magne-Blast Circuit Breaker; 1200 amp, 4.76 KV. Electrically operated, draw-out, model #6351051 AA. Used electrically OK.
SKU: AM-2.4/4.16-100/150-#22361

AM-4.16-250-7C GE Magne-Blast Air Breaker 2000A 4.76KV EO/DO

General Electric AM-4.16-250-7C Magne-Blast Circuit Breaker; 2000 amp, 4.76 KV. Electrically operated, draw-out. Used electrically OK.
SKU: AM-4.16-250-7C-EO-DO-#21952

AMH 4.76-250-OD G.E. 5KV 1200A EO/DO Magne-Blast Air Breaker

General Electric AMH 4.76-250-OD Magne-Blast Air Circuit Breaker; 1200 amp, 5 KV rated. Electrically operated, draw-out, close coil: 190-250, trip coli: 28-60, mech type: ML-13, date: 03/69. Used as-is.
SKU: AMH 4.76-250-OD-EMSCO #19565

Used and Refurbished Air Circuit Breakers

Air Circuit Breakers (ACB’s) use air to extinguish electrical sparks. When a fault occurs, these circuit breakers disrupt the circuit by releasing a burst of compressed air, extinguishing the arc. This isolates the defective section of the system, preventing damage. High-pressure air cools the electrical arc.

Inventory Selection of Air Circuit Breakers to Match and Replace Yours

Our inventory features a wide range of air circuit breaker types to match and replace your existing electrical equipment seamlessly, ensuring compatibility and optimal performance for different applications. Whether you need a specific voltage rating, current capacity, or unique design, we have options that suit your needs.

New and Refurbished Air Circuit Breakers -- It's Your Choice

We offer customers the flexibility to choose between new and refurbished ACB’s. New circuit breakers ensure the latest technology and warranties, while refurbished breakers provide cost-effective solutions without compromising quality, backed by thorough inspections and testing.

Electrical testing equipment Certifies Quality and Performance

Our products undergo rigorous electrical testing using the newest test equipment to guarantee quality, safety, and optimal performance. Each air circuit breaker is thoroughly inspected, ensuring it meets industry standards and specifications.

Specifications Based on Your Power Requirements

To specify the right air circuit breaker, consider power requirements such as voltage, current rating, breaking capacity, and the type of application. In most cases, air circuit breakers are used where there’s high risk of fire or explosion. Air Breakers are typically used for low voltages up to 15KV.

Our expert team can guide you through selecting the most suitable breaker for your specific power needs.

What Type of Air Circuit Breaker Do You Need?

Air Breaker Type

How the Breaker Type Works

Applications

Plain Break Air Breaker

Utilizes a pair of contacts within a chamber filled with air to interrupt the electrical circuit. When the contacts separate, an arc forms and is extinguished by the surrounding air.

Commonly used in low-voltage applications like residential and commercial settings, protecting against overcurrents and short circuits.

Magnetic Blowout Air Breaker

Uses a magnetic field to drive the arc away from the contacts, ensuring quick interruption and extinguishing of the arc. The magnetic force redirects the arc into a chute, effectively extinguishing it.

Often found in industrial and heavy-duty settings due to their capability to handle high fault currents, making them ideal for heavy machinery and large-scale equipment protection.

Air Chute Breaker

Uses a series of parallel plates to create a chute for the arc. When the contacts open, the arc is diverted into the chute, where it is elongated, cooled, and extinguished before being directed toward the exhaust vent.

Commonly applied in medium-voltage power distribution systems, particularly in substations, to protect transformers and other critical power equipment from faults and overloads.

Air Blast Breaker

Relies on a high-pressure air blast to extinguish the arc. The compressed air directed towards the arc causes rapid cooling and interruption, ensuring efficient breaking of the circuit.

Primarily utilized in high-voltage applications like power stations and critical infrastructure such as data centers and hospitals, offering reliable protection against high fault currents and maintaining system integrity.