Air Circuit Breakers

While our website showcases a large assortment of our products, it does not reflect the complete inventory of products currently available. For real-time availability and to ensure we can meet your specific needs, please contact our sales team at 1-800-328-1842. New products arrive daily and our knowledgeable staff are happy to assist you in locating the exact item(s) you need.

DS416 Square D 1600 Amp 635 Volts MO/DO Air Breaker LSI

Square D DS416 low voltage AC power circuit breaker; 1600 amp, 635 volts. Manually operated, draw-out with LSI functions. Used electrically OK.
SKU: DS416 EMSCO#22674

DS416 Square D 600 Volts 1600 Amps MO/DO Air Breaker LSI

Square D DS416 low voltage AC power circuit breaker; 600 volts, 1600 amps. Manually operated, draw-out with LSI functions. Used electrically OK.
SKU: DS416 EMSCO#22678

DS416 Square D 600 Volts 1600 Amps MO/DO Air Breaker LSI

Square D DS416 low voltage AC power circuit breaker; 600 volts, 1600 amps. Manually operated, draw-out, LSI Functions. Used electrically OK.
SKU: DS416 EMSCO#22679

DS416 Square D 600 Volts 1600 Amps MO/DO LSI

Square D DS-416 low voltage AC power circuit breaker; 600 volts, 1600 amps. Manually operated, draw-out with LSI functions. Used electrically OK.
SKU: DS416 EMSCO#22680

DS416 Square D 600 Volts 1600 Amps MO/DO LSI

Square D DS416 low voltage AC power circuit breaker; 600 volts, 1600 amps. Manually operated, draw-out, with LSI functions. Used electrically OK.
SKU: DS416 EMSCO#22681

DS416 Square D 635 Volts 1600 Amps MO/DO LSI

Square D DS416 low voltage AC power circuit breaker; 635 volts, 1600 amps. Manually operated, draw-out with LSI functions. Used electrically OK.
SKU: DS416 EMSCO#22676

DS416 Square D 635 Volts 1600 Amp MO/DO LSI

Square D DS416 low voltage AC power circuit breaker; 635 volts, 1600 amps. Manually operated, draw-out with LSI functions. Used electrically OK.
SKU: DS416 EMSCO#22677

DS416 Square D 635 Volts 1600 Amps MO/DO Air Breaker LSI

Square D DS416 low voltage AC power circuit breaker; 635 volts, 1600 amps. Manually operated, draw-out with LSI functions. Used electrically OK.
SKU: DS416 EMSCO#22675

DS416 Sq D 1600A Frame / 1000A Rating Plug MO/DO Air Breaker LSIG

Square D DS-416 low voltage AC power circuit breaker; 1600 amp frame, 1000 amp rating plug (RP6D16A100). Manually operated, draw-out, Digitrip RMS 510 S56LSIG with LSIG functions. Used electrically OK.
SKU: DS416 #20216

DS416 Sq D 1600A Frame / 1000A Rating Plug MO/DO Air Breaker LSIG

Square D DS-416 low voltage AC power circuit breaker; 1600 amp frame, 1000 amp rating plug (RP6D16A100). Manually operated, draw-out, Digitrip RMS 510 S56LSIG (LSIG functions). Used electrically OK.
SKU: DS416 #20219

DS416 Sq D 1600A Frame / 1000A Rating Plug MO/DO Air Breaker LSIG

Square D DS-416 low voltage AC power circuit breaker; 1600 amp frame, 1200 amp rating plug (RP6D16A120). Manually operated, draw-out. Digitrip RMS 510 S56LSIG (LSIG functions). Used electrically OK.
SKU: DS416 #20222

DS416 Square D 1600A Frame / 800A Sensors MO/DO Air Breaker LIG

Square D DS-416 low voltage AC power circuit breaker; 1600 amp frame, 800 amp sensors. Manually operated, draw-out, Amptector I-A Model with LIG functions, 120 volt AC shunt trip. Used electrically OK.
SKU: DS416 #20595

DS416 Square D 1600A Frame / 800A Sensors MO/DO Air Breaker LIG

Square D DS-416 low voltage AC power circuit breaker; 1600 amp frame, 800 amp sensors. Manually operated, draw-out, Amptector I-A Model with LIG functions, 120 volt AC shunt trip. Used electrically OK.
SKU: DS416 #20596

DS416 SQ D 1600A FRAME/ 1600A SENSORS MO/DO AIR BREAKER 120 VAC S.T. LIG

SQUARE D DS-416 low voltage AC power circuit breaker; 1600 amp frame, 1600 amp sensors. Manually operated, draw-out, S54LIG trip unit with LIG functions #RP6D16A160 (1600 amp rating plug), 120 VAC shunt trip. Used electrically OK.
SKU: DS416 EMSCO #21313

DS416 SQ D 1600A FRAME/ 1600A SENSORS MO/DO AIR BEAKER LSI

SQUARE D DS-416 low voltage AC power circuit breaker; 1600 amp frame; 1600 amp sensors. Manually operated, draw-out, Ampector 1-A Model with LSI functions. Used electrically OK.
SKU: DS416 EMSCO #21314

DS416 Sq D 1600A Frame/ 1600A Sensors MO/DO Air Breaker LSIG

Square D DS-416 low voltage AC power circuit breaker; 1600 amp frame, 1600 amp sensors. Manually operated, draw-out, Ampector I-A Model with LSIG functions. Used electrically OK.
SKU: DS416 EMSCO #20869

DS416 Square D 1600A Frame/1600A Sensors 600V Air Breaker MO/DO LSIG

Square D DS416 low voltage AC power circuit breaker; 1600 amp frame, 1600 amp sensors. Manually operated, draw-out, Amptector I-A Model with LSIG functions. Used electrically OK.
SKU: DS416 #20668

DS-416 Square D 1600A 600V MO/DO Air Breaker LSG

Square D DS-416 low voltage AC power circuit breaker; 1600 amp, 600 volt. Manually operated, draw-out, with LSG functions. Used electrically OK.
SKU: DS-416 #22671

DS-416 Square D 1600A 635V MO/DO Air Breaker LSG

Square D DS-416 low voltage power circuit breaker; 1600 amp, 635 volts. Manually operated, draw-out with LSG functions. Used electrically OK.
SKU: DS-416 #22672

DS-416 Square D 1600A 600V MO/DO Air Breaker LSG

Square D DS-416 low voltage power circuit breaker; 1600 amp, 600 volt. Manually operated, draw-out with LSG functions. Used electrically OK.
SKU: DS-416 #22673

Used and Refurbished Air Circuit Breakers

Air Circuit Breakers (ACB’s) use air to extinguish electrical sparks. When a fault occurs, these circuit breakers disrupt the circuit by releasing a burst of compressed air, extinguishing the arc. This isolates the defective section of the system, preventing damage. High-pressure air cools the electrical arc.

Inventory Selection of Air Circuit Breakers to Match and Replace Yours

Our inventory features a wide range of air circuit breaker types to match and replace your existing electrical equipment seamlessly, ensuring compatibility and optimal performance for different applications. Whether you need a specific voltage rating, current capacity, or unique design, we have options that suit your needs.

New and Refurbished Air Circuit Breakers -- It's Your Choice

We offer customers the flexibility to choose between new and refurbished ACB’s. New circuit breakers ensure the latest technology and warranties, while refurbished breakers provide cost-effective solutions without compromising quality, backed by thorough inspections and testing.

Electrical testing equipment Certifies Quality and Performance

Our products undergo rigorous electrical testing using the newest test equipment to guarantee quality, safety, and optimal performance. Each air circuit breaker is thoroughly inspected, ensuring it meets industry standards and specifications.

Specifications Based on Your Power Requirements

To specify the right air circuit breaker, consider power requirements such as voltage, current rating, breaking capacity, and the type of application. In most cases, air circuit breakers are used where there’s high risk of fire or explosion. Air Breakers are typically used for low voltages up to 15KV.

Our expert team can guide you through selecting the most suitable breaker for your specific power needs.

What Type of Air Circuit Breaker Do You Need?

Air Breaker Type

How the Breaker Type Works

Applications

Plain Break Air Breaker

Utilizes a pair of contacts within a chamber filled with air to interrupt the electrical circuit. When the contacts separate, an arc forms and is extinguished by the surrounding air.

Commonly used in low-voltage applications like residential and commercial settings, protecting against overcurrents and short circuits.

Magnetic Blowout Air Breaker

Uses a magnetic field to drive the arc away from the contacts, ensuring quick interruption and extinguishing of the arc. The magnetic force redirects the arc into a chute, effectively extinguishing it.

Often found in industrial and heavy-duty settings due to their capability to handle high fault currents, making them ideal for heavy machinery and large-scale equipment protection.

Air Chute Breaker

Uses a series of parallel plates to create a chute for the arc. When the contacts open, the arc is diverted into the chute, where it is elongated, cooled, and extinguished before being directed toward the exhaust vent.

Commonly applied in medium-voltage power distribution systems, particularly in substations, to protect transformers and other critical power equipment from faults and overloads.

Air Blast Breaker

Relies on a high-pressure air blast to extinguish the arc. The compressed air directed towards the arc causes rapid cooling and interruption, ensuring efficient breaking of the circuit.

Primarily utilized in high-voltage applications like power stations and critical infrastructure such as data centers and hospitals, offering reliable protection against high fault currents and maintaining system integrity.